Comparison · Air dryers
MTA air dryers
5 refrigerated, desiccant lines (cycling, heatless, heated purge), from the manufacturer’s brochures.
Under construction. This comparison tool is still being built: do not base a purchasing decision on this data. Always confirm with your local distributors.
All manufacturers Search by need (refrigerated)Search by need (desiccant)
DE iTECH
- Flow
- 18 to 1,920 m³/h (≈ 11 to 1,130 SCFM)at the manufacturer’s reference conditions (calc. from 0.3–32 m³/min)
- Dew point
- n/aISO class 4
- ISO 8573-1 class
- Class 4
- Frequency
- 50 Hz · 60 Hz
- Voltages
- 230/1/50 · 400/3/50 · 460/3/60
- CSA · CRN
- n/a · n/a
- Features
- Impulse control
- Sources
- Manufacturer’s page
Models
All models: Type Non-cyclingDew point 3 °C (37.4 °F)ISO class Class 4
| Model | Flow | Voltage |
|---|---|---|
| DEiT 003 | ≈ 11 SCFM18 m³/h | 230/1/50 |
| DEiT 005 | ≈ 18 SCFM30 m³/h | 230/1/50 |
| DEiT 007 | ≈ 25 SCFM42 m³/h | 230/1/50 |
| DEiT 009 | ≈ 32 SCFM54 m³/h | 230/1/50 |
| DEiT 012 | ≈ 42 SCFM72 m³/h | 230/1/50 |
| DEiT 018 | ≈ 64 SCFM108 m³/h | 230/1/50 |
| DEiT 026 | ≈ 92 SCFM156 m³/h | 230/1/50 |
| DEiT 032 | ≈ 113 SCFM192 m³/h | 230/1/50 |
| DEiT 040 | ≈ 141 SCFM240 m³/h | 230/1/50 |
| DEiT 050 | ≈ 177 SCFM300 m³/h | 230/1/50 |
| DEiT 060 | ≈ 212 SCFM360 m³/h | 230/1/50 |
| DEiT 070 | ≈ 247 SCFM420 m³/h | 230/1/50 |
| DEiT 080 | ≈ 283 SCFM480 m³/h | 230/1/50 |
| DEiT 101 | ≈ 353 SCFM600 m³/h | 230/1/50-60 |
| DEiT 121 | ≈ 424 SCFM720 m³/h | 230/1/50 |
| DEiT 140 | ≈ 494 SCFM840 m³/h | 230/1/50 |
| DEiT 165 | ≈ 583 SCFM990 m³/h | 400/3/50 (460/3/60) |
| DEiT 190 | ≈ 671 SCFM1,140 m³/h | 400/3/50 (460/3/60) |
| DEiT 230 | ≈ 812 SCFM1,380 m³/h | 400/3/50 (460/3/60) |
| DEiT 270 | ≈ 954 SCFM1,620 m³/h | 400/3/50 (460/3/60) |
| DEiT 320 | ≈ 1,130 SCFM1,920 m³/h | 400/3/50 (460/3/60) |
Comparable lines (6)
- Purestream (Friulair) ACT ES
- Sullair SRN / SRD
- Gardner Denver GDDF-ES
- Sullivan-Palatek SPR
- Pneumatech AC VSD
- ZEKS HeatSink HSH/HSG 300-1600
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
DryXtreme NDA (molecular sieve)
- Flow
- 19 to 2,480 m³/h (≈ 11 to 1,460 SCFM)at the manufacturer’s reference conditions
- Dew point
- -60 °C (-76 °F)-60 °C
- ISO 8573-1 class
- Class 2 (derived)
- Frequency
- 50 Hz (60 Hz on request)
- Voltages
- 230/1/50
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessConditions Reference FAD 20 °C, 1 bar a, inlet 35 °CDew point -60 °C (-76 °F)ISO class Class 2 (derived)Voltage 230/1/50
| Model | Flow |
|---|---|
| NDA-M25 | ≈ 11 SCFM19 m³/h |
| NDA-M50 | ≈ 22 SCFM37 m³/h |
| NDA-M75 | ≈ 33 SCFM56 m³/h |
| NDA-001 | ≈ 33 SCFM56 m³/h |
| NDA-002 | ≈ 42 SCFM71 m³/h |
| NDA-003 | ≈ 67 SCFM113 m³/h |
| NDA-004 | ≈ 97 SCFM164 m³/h |
| NDA-005 | ≈ 146 SCFM248 m³/h |
| NDA-006 | ≈ 177 SCFM300 m³/h |
| NDA-007 | ≈ 242 SCFM412 m³/h |
| NDA-008 | ≈ 300 SCFM510 m³/h |
| NDA-009 | ≈ 345 SCFM586 m³/h |
| NDA-010 | ≈ 442 SCFM751 m³/h |
| NDA-011 | ≈ 531 SCFM902 m³/h |
| NDA-012 | ≈ 663 SCFM1,127 m³/h |
| NDA-013 | ≈ 796 SCFM1,353 m³/h |
| NDA-014 | ≈ 972 SCFM1,652 m³/h |
| NDA-015 | ≈ 1,105 SCFM1,878 m³/h |
| NDA-016 | ≈ 1,460 SCFM2,480 m³/h |
Comparable lines (8)
- Pneumatech PH 55-310 HE (US)
- BEKO Technologies DRYPOINT AC HP
- Ultrafilter HeatLess HL
- Altec AIR HOF oil field
- ALUP AD 90-940
- Worthington Creyssensac DB 90-940
- Atlas Copco CD 25-260
- Altec AIR HLD basse PDP
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
DryXtreme NA
- Flow
- 7 to 110 m³/h (≈ 4 to 65 SCFM)at the manufacturer’s reference conditions
- Dew point
- -70 to -40 °C (-94 to -40 °F)-40 °C (up to -70 °C)
- ISO 8573-1 class
- Class 1 to 2 (derived)
- Frequency
- n/a
- Voltages
- n/a
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessConditions Reference 20 °C/1 bar a, 7 bar(ü), inlet 35 °C, PDP -40 °CDew point -70 to -40 °C (-94 to -40 °F)ISO class Class 1 to 2 (derived)
Comparable lines (8)
- Kaeser DC-HF
- Chicago Pneumatic CPADM (modular)
- BEKO Technologies DRYPOINT ACC
- ALUP AD 7-60
- Worthington Creyssensac DB 05-6
- Ingersoll Rand DA…IM (modular)
- Deltech DHDM (modular)
- Hankison PHDM (modular)
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
DryXtreme NDA (alumina)
- Flow
- 27 to 3,543 m³/h (≈ 16 to 2,085 SCFM)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °C
- ISO 8573-1 class
- Class 2 (derived)
- Frequency
- 50 Hz (60 Hz on request)
- Voltages
- 230/1/50
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessConditions Reference FAD 20 °C, 1 bar a, inlet 35 °CDew point -40 °C (-40 °F)ISO class Class 2 (derived)Voltage 230/1/50
| Model | Flow |
|---|---|
| NDA-M25 | ≈ 16 SCFM27 m³/h |
| NDA-M50 | ≈ 31 SCFM53 m³/h |
| NDA-M75 | ≈ 47 SCFM80 m³/h |
| NDA-001 | ≈ 47 SCFM80 m³/h |
| NDA-002 | ≈ 59 SCFM101 m³/h |
| NDA-003 | ≈ 95 SCFM161 m³/h |
| NDA-004 | ≈ 138 SCFM235 m³/h |
| NDA-005 | ≈ 209 SCFM355 m³/h |
| NDA-006 | ≈ 253 SCFM429 m³/h |
| NDA-007 | ≈ 347 SCFM589 m³/h |
| NDA-008 | ≈ 429 SCFM729 m³/h |
| NDA-009 | ≈ 493 SCFM837 m³/h |
| NDA-010 | ≈ 632 SCFM1,073 m³/h |
| NDA-011 | ≈ 758 SCFM1,288 m³/h |
| NDA-012 | ≈ 948 SCFM1,610 m³/h |
| NDA-013 | ≈ 1,138 SCFM1,933 m³/h |
| NDA-014 | ≈ 1,390 SCFM2,361 m³/h |
| NDA-015 | ≈ 1,579 SCFM2,683 m³/h |
| NDA-016 | ≈ 2,085 SCFM3,543 m³/h |
Comparable lines (8)
- BEKO Technologies DRYPOINT AC 410-495
- Altec AIR HLD basse PDP
- Pneumatic Products (SPX) CDA Heat-Les
- Atlas Copco CD 25-260
- ALUP AD 90-940
- Worthington Creyssensac DB 90-940
- Van Air Systems HLSXG (antidéflagrant, gaz naturel)
- Altec AIR HHP high pressure
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
DryXtreme NST
- Flow
- 116 to 8,903 m³/h (≈ 68 to 5,240 SCFM)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °C (alumina); molecular sieve on request
- ISO 8573-1 class
- Class 2 (derived)
- Frequency
- 50 Hz (60 Hz on request)
- Voltages
- 400/3/50
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Heated purgeConditions Reference FAD 20 °C, 1 bar a, inlet 35 °CDew point -40 °C (-40 °F)ISO class Class 2 (derived)Voltage 400/3/50
| Model | Flow |
|---|---|
| NST 18 | ≈ 68 SCFM116 m³/h |
| NST 30 | ≈ 114 SCFM193 m³/h |
| NST 45 | ≈ 171 SCFM290 m³/h |
| NST 70 | ≈ 265 SCFM451 m³/h |
| NST 110 | ≈ 417 SCFM709 m³/h |
| NST 140 | ≈ 531 SCFM903 m³/h |
| NST 210 | ≈ 797 SCFM1,354 m³/h |
| NST 300 | ≈ 1,139 SCFM1,935 m³/h |
| NST 400 | ≈ 1,519 SCFM2,580 m³/h |
| NST 510 | ≈ 1,936 SCFM3,290 m³/h |
| NST 630 | ≈ 2,392 SCFM4,064 m³/h |
| NST 810 | ≈ 3,075 SCFM5,225 m³/h |
| NST 1000 | ≈ 3,797 SCFM6,451 m³/h |
| NST 1380 | ≈ 5,240 SCFM8,903 m³/h |
Comparable lines (8)
- Sullivan-Palatek SPDH Pro Heated Purge
- Sullivan-Palatek SPDHR Premium Heated Purge
- Champion XCHP
- Nano Purification D5 EH (US)
- BEKO Technologies DRYPOINT ACH
- Mattei MEH
- Altec AIR HRE
- Deltech RP
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
Equivalent equipment at Onyx M3
Purestream (Friulair) refrigerated dryers, distributed by Onyx M3 Inc.
Is your product missing?
Request received. We will proceed within 72 hours.