Comparison · Air dryers

Champion air dryers

6 refrigerated, desiccant lines (non-cycling, heatless, heated purge, blower purge), from the manufacturer’s brochures.

Under construction. This comparison tool is still being built: do not base a purchasing decision on this data. Always confirm with your local distributors.

CGD / CGDA

NON-CYC ISO 5–6 North America 60 Hz CSA
Flow
7 to 1,200 SCFM (≈ 12 to 2,039 m³/h)at the manufacturer’s reference conditions
Dew point
n/aISO 8573-1 class 5–6
ISO 8573-1 class
Class 5 to 6
Frequency
60 Hz
Voltages
115/1/60 · 460/3/60
CSA · CRN
yes (CSA approved) · n/a

Models

All models: Type Non-cyclingConditions 100 psig/100 °FISO class Class 5 to 6

Model Flow Voltage
CGDA7A1CGDA 7 SCFM11.9 m³/h 115/1/60
CGDA11A1CGDA 11 SCFM18.7 m³/h 115/1/60
CGDA15A1CGDA 15 SCFM25.5 m³/h 115/1/60
CGDA25A1CGDA 25 SCFM42.5 m³/h 115/1/60
CGDA32A1CGDA 32 SCFM54.4 m³/h 115/1/60
CGDA42A1CGDA 42 SCFM71.4 m³/h 115/1/60
CGDA50A1CGDA 50 SCFM85 m³/h 115/1/60
CGD75A1CGD 75 SCFM127 m³/h 115/1/60
CGD100A1CGD 100 SCFM170 m³/h 115/1/60
CGD125A1CGD 125 SCFM212 m³/h 115/1/60
CGD150A1CGD 150 SCFM255 m³/h 115/1/60
CGD200A4CGD 200 SCFM340 m³/h 460/3/60
CGD250A4CGD 250 SCFM424 m³/h 460/3/60
CGD300A4CGD 300 SCFM509 m³/h 460/3/60
CGD400A4CGD 400 SCFM680 m³/h 460/3/60
CGD500A4CGD 500 SCFM849 m³/h 460/3/60
CGD600A4CGD 600 SCFM1,019 m³/h 460/3/60
CGD600W4CGD 600 SCFM1,019 m³/h 460/3/60
CGD800A4CGD 800 SCFM1,359 m³/h 460/3/60
CGD800W4CGD 800 SCFM1,359 m³/h 460/3/60
CGD1000A4CGD 1,000 SCFM1,699 m³/h 460/3/60
CGD1000W4CGD 1,000 SCFM1,699 m³/h 460/3/60
CGD1200A4CGD 1,200 SCFM2,038 m³/h 460/3/60
CGD1200W4CGD 1,200 SCFM2,038 m³/h 460/3/60
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

CRH

NON-CYC North America 60 Hz

Recorded wording: CRH haute température d'inlet

Flow
15 to 100 SCFM (≈ 25 to 170 m³/h)at the manufacturer’s reference conditions
Dew point
n/a
ISO 8573-1 class
n/a
Frequency
60 Hz
Voltages
115/1/60
CSA · CRN
n/a · n/a
Features
High inlet temperature

CDT

HL ISO 1–2 North America 60 Hz 50 Hz
Flow
40 to 5,400 SCFM (≈ 68 to 9,175 m³/h)at the manufacturer’s reference conditions
Dew point
-73.3 to -40 °C (-99.9 to -40 °F)-40 °F (class 2) or -100 °F (class 1), selectable
ISO 8573-1 class
Class 1 to 2
Frequency
50 Hz · 60 Hz
Voltages
85-264 VAC 47-63 Hz or 11.5-28 VDC (controller)
CSA · CRN
n/a · n/a

Models

All models: Type HeatlessDew point -73.3 to -40 °C (-99.9 to -40 °F)ISO class Class 1 to 2Voltage 85-264 VAC 47-63 Hz or 11.5-28 VDC (controller)

Model Flow
CDT40 40 SCFM≈ 68 m³/h
CDT60 60 SCFM≈ 102 m³/h
CDT90 90 SCFM≈ 153 m³/h
CDT115 115 SCFM≈ 195 m³/h
CDT165 165 SCFM≈ 280 m³/h
CDT260 260 SCFM≈ 442 m³/h
CDT370 370 SCFM≈ 629 m³/h
CDT450 450 SCFM≈ 765 m³/h
CDT590 590 SCFM≈ 1,002 m³/h
CDT750 750 SCFM≈ 1,274 m³/h
CDT930 930 SCFM≈ 1,580 m³/h
CDT1130 1,130 SCFM≈ 1,920 m³/h
CDT1350 1,350 SCFM≈ 2,294 m³/h
CDT1550 1,550 SCFM≈ 2,633 m³/h
CDT2100 2,100 SCFM≈ 3,568 m³/h
CDT3000 3,000 SCFM≈ 5,097 m³/h
CDT4100 4,100 SCFM≈ 6,966 m³/h
CDT5400 5,400 SCFM≈ 9,175 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

XCHL

HL ISO 1 North America
Flow
90 to 3,300 SCFM (150 to 5,610 m³/h)at the manufacturer’s reference conditions
Dew point
-73 °C (-99.4 °F)n/a standard (optional class 1 -100 °F / -73 °C)
ISO 8573-1 class
Class 1
Frequency
n/a
Voltages
n/a
CSA · CRN
n/a · n/a

Models

All models: Type HeatlessDew point -73 °C (-99.4 °F)ISO class Class 1

Model Flow
XCHL90 90 SCFM150 m³/h
XCHL120 120 SCFM204 m³/h
XCHL160 160 SCFM270 m³/h
XCHL200 200 SCFM342 m³/h
XCHL250 250 SCFM426 m³/h
XCHL300 300 SCFM510 m³/h
XCHL400 400 SCFM678 m³/h
XCHL500 500 SCFM852 m³/h
XCHL600 600 SCFM1,020 m³/h
XCHL800 800 SCFM1,362 m³/h
XCHL1000 1,000 SCFM1,698 m³/h
XCHL1200 1,200 SCFM2,040 m³/h
XCHL1500 1,500 SCFM2,550 m³/h
XCHL1800 1,800 SCFM3,060 m³/h
XCHL2100 2,100 SCFM3,570 m³/h
XCHL2700 2,700 SCFM4,590 m³/h
XCHL3300 3,300 SCFM5,610 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

XCHB

BP ISO 2 ≈ North America
Flow
150 to 3,000 SCFM (252 to 5,094 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °F / -40 °C
ISO 8573-1 class
Class 2 (derived)
Frequency
n/a
Voltages
n/a
CSA · CRN
n/a · n/a

Models

All models: Type Blower purgeDew point -40 °C (-40 °F)ISO class Class 2 (derived)

Model Flow
XCHB150 150 SCFM252 m³/h
XCHB200 200 SCFM342 m³/h
XCHB250 250 SCFM426 m³/h
XCHB300 300 SCFM510 m³/h
XCHB400 400 SCFM678 m³/h
XCHB500 500 SCFM852 m³/h
XCHB600 600 SCFM1,020 m³/h
XCHB800 800 SCFM1,362 m³/h
XCHB1000 1,000 SCFM1,698 m³/h
XCHB1200 1,200 SCFM2,040 m³/h
XCHB1500 1,500 SCFM2,550 m³/h
XCHB1800 1,800 SCFM3,060 m³/h
XCHB2100 2,100 SCFM3,570 m³/h
XCHB2700 2,700 SCFM4,590 m³/h
XCHB3000 3,000 SCFM5,094 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

XCHP

EH ISO 2 ≈ North America
Flow
150 to 3,000 SCFM (252 to 5,094 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °F / -40 °C
ISO 8573-1 class
Class 2 (derived)
Frequency
n/a
Voltages
n/a
CSA · CRN
n/a · n/a

Equivalent equipment at Onyx M3

Purestream (Friulair) refrigerated dryers, distributed by Onyx M3 Inc.