Comparison · Air dryers
Hankison air dryers
9 refrigerated, desiccant lines (non-cycling, heatless, blower purge, heated purge), from the manufacturer’s brochures.
Under construction. This comparison tool is still being built: do not base a purchasing decision on this data. Always confirm with your local distributors.
All manufacturers Search by need (refrigerated)Search by need (desiccant)
HPRB
- Flow
- 7 to 1,200 SCFM (12 to 2,040 m³/h)at the manufacturer’s reference conditions
- Dew point
- n/aISO 8573-1 class 5–6
- ISO 8573-1 class
- Class 5 to 6
- Frequency
- 60 Hz
- Voltages
- 115/1/60 · 460/3/60
- CSA · CRN
- yes (CSA 22.2 #60335-1/-2-40) · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Non-cyclingConditions ISO 7183 optional A2 (100 psig/100 °FISO class Class 5 to 6
| Model | Flow | Voltage |
|---|---|---|
| HPRB7-A | 7 SCFM≈ 12 m³/h | 115/1/60 |
| HPRB11-A | 11 SCFM≈ 19 m³/h | 115/1/60 |
| HPRB15-A | 15 SCFM≈ 25 m³/h | 115/1/60 |
| HPRB25-A | 25 SCFM≈ 42 m³/h | 115/1/60 |
| HPRB32-A | 32 SCFM≈ 54 m³/h | 115/1/60 |
| HPRB42-A | 42 SCFM≈ 71 m³/h | 115/1/60 |
| HPRB50-A | 50 SCFM≈ 85 m³/h | 115/1/60 |
| HPRB75-A | 75 SCFM≈ 127 m³/h | 115/1/60 |
| HPRB100-A | 100 SCFM≈ 170 m³/h | 115/1/60 |
| HPRB125-A | 125 SCFM≈ 212 m³/h | 115/1/60 |
| HPRB150-A | 150 SCFM≈ 255 m³/h | 115/1/60 |
| HPRB200-A | 200 SCFM≈ 340 m³/h | 460/3/60 |
| HPRB250-A | 250 SCFM≈ 425 m³/h | 460/3/60 |
| HPRB300-A | 300 SCFM≈ 510 m³/h | 460/3/60 |
| HPRB400-A | 400 SCFM≈ 680 m³/h | 460/3/60 |
| HPRB500-A | 500 SCFM≈ 850 m³/h | 460/3/60 |
| HPRB600-A | 600 SCFM≈ 1,019 m³/h | 460/3/60 |
| HPRB800-A | 800 SCFM≈ 1,359 m³/h | 460/3/60 |
| HPRB1000-A | 1,000 SCFM≈ 1,699 m³/h | 460/3/60 |
| HPRB1200-A | 1,200 SCFM≈ 2,039 m³/h | 460/3/60 |
Comparable lines (8)
- Champion CGD / CGDA
- Atlas Copco FD / FD VSD / FX
- ABAC DRY 20-1260
- BOGE DS-2
- Chicago Pneumatic CPX 10-4200
- Ingersoll Rand D-IN / D-IT
- BEKO Technologies DRYPOINT RA III
- Aircel VF / DHT
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
PHDM (modular)
- Flow
- 3 to 177 SCFM (≈ 5 to 301 m³/h)at the manufacturer’s reference conditions
- Dew point
- -70 to -40 °C (-94 to -40 °F)-40 °F/-40 °C (class 2) or -94 °F/-70 °C (class 1), selectable
- ISO 8573-1 class
- Class 1 to 2
- Frequency
- n/a
- Voltages
- n/a
- CSA · CRN
- yes : CSA C22.2 No.0-10 / No.14-18 & UL 508 · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessConditions @100 psigDew point -70 to -40 °C (-94 to -40 °F)ISO class Class 1 to 2
Comparable lines (8)
- Deltech DHDM (modular)
- ZEKS ZMA (modular)
- Ingersoll Rand DA…IM (modular)
- BEKO Technologies DRYPOINT ACC
- Sullair DMD (modular)
- Kaeser DC-HF
- MTA DryXtreme NA
- Chicago Pneumatic CPADM (modular)
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
HHE
- Flow
- 40 to 5,400 SCFM (68 to 9,175 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °F/-40 °C (class 2)
- ISO 8573-1 class
- Class 2
- Frequency
- 50 Hz · 60 Hz
- Voltages
- 100-120V/1ph/50-60Hz
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessConditions @100 psigDew point -40 °C (-40 °F)ISO class Class 2Voltage 100-120V/1ph/50-60Hz
| Model | Flow |
|---|---|
| HHE-40 | 40 SCFM68 m³/h |
| HHE-60 | 60 SCFM102 m³/h |
| HHE-90 | 90 SCFM153 m³/h |
| HHE-115 | 115 SCFM195 m³/h |
| HHE-165 | 165 SCFM280 m³/h |
| HHE-260 | 260 SCFM442 m³/h |
| HHE-370 | 370 SCFM629 m³/h |
| HHE-450 | 450 SCFM765 m³/h |
| HHE-590 | 590 SCFM1,002 m³/h |
| HHE-750 | 750 SCFM1,274 m³/h |
| HHE-930 | 930 SCFM1,580 m³/h |
| HHE-1130 | 1,130 SCFM1,920 m³/h |
| HHE-1350 | 1,350 SCFM2,294 m³/h |
| HHE-1550 | 1,550 SCFM2,634 m³/h |
| HHE-2100 | 2,100 SCFM3,568 m³/h |
| HHE-3000 | 3,000 SCFM5,097 m³/h |
| HHE-4100 | 4,100 SCFM6,966 m³/h |
| HHE-5400 | 5,400 SCFM9,175 m³/h |
Comparable lines (8)
- Champion CDT
- Gardner Denver DGH
- Kaeser KAD
- Nano Purification D5 HL (US)
- BEKO Technologies DRYPOINT XCp
- Sullivan-Palatek SPDPR Premium Heatless
- Altec AIR MHR
- CompAir A-Series AX…NS (modular)
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
HHX
- Flow
- 40 to 5,400 SCFM (68 to 9,175 m³/h)at the manufacturer’s reference conditions
- Dew point
- -73.3 to -20 °C (-99.9 to -4 °F)-100/-40/-4 °F (classes 1-3, selectable)
- ISO 8573-1 class
- Classes 1, 2, 3
- Frequency
- n/a
- Voltages
- n/a
- CSA · CRN
- yes : CSA C22.2 No.0-10/No.14-18 & UL 508 (stated HHX) · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessConditions @100 psigDew point -73.3 to -20 °C (-99.9 to -4 °F)ISO class Classes 1, 2, 3
| Model | Flow |
|---|---|
| HHX-40 | 40 SCFM68 m³/h |
| HHX-60 | 60 SCFM102 m³/h |
| HHX-90 | 90 SCFM153 m³/h |
| HHX-115 | 115 SCFM195 m³/h |
| HHX-165 | 165 SCFM280 m³/h |
| HHX-260 | 260 SCFM442 m³/h |
| HHX-370 | 370 SCFM629 m³/h |
| HHX-450 | 450 SCFM765 m³/h |
| HHX-590 | 590 SCFM1,002 m³/h |
| HHX-750 | 750 SCFM1,274 m³/h |
| HHX-930 | 930 SCFM1,580 m³/h |
| HHX-1130 | 1,130 SCFM1,920 m³/h |
| HHX-1350 | 1,350 SCFM2,294 m³/h |
| HHX-1550 | 1,550 SCFM2,634 m³/h |
| HHX-2100 | 2,100 SCFM3,568 m³/h |
| HHX-3000 | 3,000 SCFM5,097 m³/h |
| HHX-4100 | 4,100 SCFM6,966 m³/h |
| HHX-5400 | 5,400 SCFM9,175 m³/h |
Comparable lines (8)
- Champion CDT
- Gardner Denver DGH
- Kaeser KAD
- BEKO Technologies DRYPOINT XCp
- Sullivan-Palatek SPDPR Premium Heatless
- Altec AIR MHR
- OMI HLA
- Parker PNEUDRI MX
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
HHS
- Flow
- 40 to 5,400 SCFM (68 to 9,175 m³/h)at the manufacturer’s reference conditions
- Dew point
- -73.3 to -20 °C (-99.9 to -4 °F)-100/-40/-4 °F (classes 1-3, selectable; on demand in cl. 2-3)
- ISO 8573-1 class
- Classes 1, 2, 3
- Frequency
- 50 Hz · 60 Hz
- Voltages
- 100-240V/1ph/50-60Hz or 12-24 VDC
- CSA · CRN
- n/a · yes : « Pressure vessels are CRN and ASME Certified »
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessConditions @100 psiDew point -73.3 to -20 °C (-99.9 to -4 °F)ISO class Classes 1, 2, 3Voltage 100-240V/1ph/50-60Hz or 12-24 VDC
| Model | Flow |
|---|---|
| HHS-40 | 40 SCFM68 m³/h |
| HHS-60 | 60 SCFM102 m³/h |
| HHS-90 | 90 SCFM153 m³/h |
| HHS-115 | 115 SCFM195 m³/h |
| HHS-165 | 165 SCFM280 m³/h |
| HHS-260 | 260 SCFM442 m³/h |
| HHS-370 | 370 SCFM629 m³/h |
| HHS-450 | 450 SCFM765 m³/h |
| HHS-590 | 590 SCFM1,002 m³/h |
| HHS-750 | 750 SCFM1,274 m³/h |
| HHS-930 | 930 SCFM1,580 m³/h |
| HHS-1130 | 1,130 SCFM1,920 m³/h |
| HHS-1350 | 1,350 SCFM2,294 m³/h |
| HHS-1550 | 1,550 SCFM2,634 m³/h |
| HHS-2100 | 2,100 SCFM3,568 m³/h |
| HHS-3000 | 3,000 SCFM5,097 m³/h |
| HHS-4100 | 4,100 SCFM6,966 m³/h |
| HHS-5400 | 5,400 SCFM9,175 m³/h |
Comparable lines (8)
- Champion CDT
- Gardner Denver DGH
- Kaeser KAD
- BEKO Technologies DRYPOINT XCp
- Sullivan-Palatek SPDPR Premium Heatless
- Altec AIR MHR
- OMI HLA
- Parker PNEUDRI MX
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
HHL
- Flow
- 40 to 5,400 SCFM (68 to 9,175 m³/h)at the manufacturer’s reference conditions
- Dew point
- -73.3 to 3.3 °C (-99.9 to 37.9 °F)-100/-40/-4/+38 °F (classes 1-4, fixed cycles)
- ISO 8573-1 class
- Classes 1, 2, 3, 4
- Frequency
- 50 Hz · 60 Hz
- Voltages
- 100-240V/1ph/50-60Hz or 12-24 VDC
- CSA · CRN
- n/a · yes : « Pressure vessels are CRN and ASME Certified »
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessConditions @100 psiDew point -73.3 to 3.3 °C (-99.9 to 37.9 °F)ISO class Classes 1, 2, 3, 4Voltage 100-240V/1ph/50-60Hz or 12-24 VDC
| Model | Flow |
|---|---|
| HHL-40 | 40 SCFM68 m³/h |
| HHL-60 | 60 SCFM102 m³/h |
| HHL-90 | 90 SCFM153 m³/h |
| HHL-115 | 115 SCFM195 m³/h |
| HHL-165 | 165 SCFM280 m³/h |
| HHL-260 | 260 SCFM442 m³/h |
| HHL-370 | 370 SCFM629 m³/h |
| HHL-450 | 450 SCFM765 m³/h |
| HHL-590 | 590 SCFM1,002 m³/h |
| HHL-750 | 750 SCFM1,274 m³/h |
| HHL-930 | 930 SCFM1,580 m³/h |
| HHL-1130 | 1,130 SCFM1,920 m³/h |
| HHL-1350 | 1,350 SCFM2,294 m³/h |
| HHL-1550 | 1,550 SCFM2,634 m³/h |
| HHL-2100 | 2,100 SCFM3,568 m³/h |
| HHL-3000 | 3,000 SCFM5,097 m³/h |
| HHL-4100 | 4,100 SCFM6,966 m³/h |
| HHL-5400 | 5,400 SCFM9,175 m³/h |
Comparable lines (8)
- Champion CDT
- Gardner Denver DGH
- Kaeser KAD
- BEKO Technologies DRYPOINT XCp
- Sullivan-Palatek SPDPR Premium Heatless
- Altec AIR MHR
- OMI HLA
- Parker PNEUDRI MX
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
HHL (international)
- Flow
- 90 to 9,000 m³/h (≈ 53 to 5,297 SCFM)at the manufacturer’s reference conditions
- Dew point
- -70 to -40 °C (-94 to -40 °F)-40 °C (cycle 10 min) / -70 °C (cycle 4 min)
- ISO 8573-1 class
- Class 1 to 2 (derived)
- Frequency
- n/a
- Voltages
- 95-240/1/50 · 95/240/1/60 (tel quel)
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessConditions ISO 7183 (7 bar(g), 35 °C)Dew point -70 to -40 °C (-94 to -40 °F)ISO class Class 1 to 2 (derived)
| Model | Flow | Voltage |
|---|---|---|
| HHL 91 | ≈ 53 SCFM90 m³/h | n/a |
| HHL 141 | ≈ 82 SCFM140 m³/h | n/a |
| HHL 271 | ≈ 159 SCFM270 m³/h | n/a |
| HHL 351 | ≈ 206 SCFM350 m³/h | n/a |
| HHL 521 | ≈ 306 SCFM520 m³/h | n/a |
| HHL 681 | ≈ 400 SCFM680 m³/h | n/a |
| HHL 901 | ≈ 530 SCFM900 m³/h | n/a |
| HHL 1051 | ≈ 618 SCFM1,050 m³/h | n/a |
| HHL 1351 | ≈ 795 SCFM1,350 m³/h | n/a |
| HHL 1651 | ≈ 971 SCFM1,650 m³/h | n/a |
| HHL 1951 | ≈ 1,148 SCFM1,950 m³/h | n/a |
| HHL 2351 | ≈ 1,383 SCFM2,350 m³/h | 95-240/1/50 |
| HHL 2701 | ≈ 1,589 SCFM2,700 m³/h | 95/240/1/60 (tel quel) |
| HHL 3601 | ≈ 2,119 SCFM3,600 m³/h | n/a |
| HHL 5201 | ≈ 3,061 SCFM5,200 m³/h | n/a |
| HHL 7101 | ≈ 4,179 SCFM7,100 m³/h | n/a |
| HHL 9001 | ≈ 5,297 SCFM9,000 m³/h | n/a |
Comparable lines (8)
- OMI HLA
- Parker PNEUDRI MX
- Champion XCHL
- Mattei MHL
- ALUP AD 650-1300 (sensor)
- Worthington Creyssensac DB 65-130
- Altec AIR MHR
- BEKO Technologies DRYPOINT XCp
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
HBP
- Flow
- 500 to 4,300 SCFM (≈ 850 to 7,306 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °F/-40 °C (class 2)
- ISO 8573-1 class
- Class 2
- Frequency
- n/a
- Voltages
- n/a
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Blower purgeConditions @100 psig, 100 °F ; CAGI ADF 200Dew point -40 °C (-40 °F)ISO class Class 2
| Model | Flow |
|---|---|
| HBP500 | 500 SCFM≈ 850 m³/h |
| HBP600 | 600 SCFM≈ 1,019 m³/h |
| HBP750 | 750 SCFM≈ 1,274 m³/h |
| HBP900 | 900 SCFM≈ 1,529 m³/h |
| HBP1050 | 1,050 SCFM≈ 1,784 m³/h |
| HBP1300 | 1,300 SCFM≈ 2,209 m³/h |
| HBP1500 | 1,500 SCFM≈ 2,549 m³/h |
| HBP1800 | 1,800 SCFM≈ 3,058 m³/h |
| HBP2200 | 2,200 SCFM≈ 3,738 m³/h |
| HBP2600 | 2,600 SCFM≈ 4,417 m³/h |
| HBP3200 | 3,200 SCFM≈ 5,437 m³/h |
| HBP3600 | 3,600 SCFM≈ 6,116 m³/h |
| HBP4300 | 4,300 SCFM≈ 7,306 m³/h |
Comparable lines (8)
- Kaeser KBD
- Pneumatic Products (SPX) IBP
- Mattei MBP
- Ingersoll Rand D…IBA
- Atlas Copco BD 360-1600
- Nano Purification D5 BP (US)
- Mattei DDH 850-10800
- Atlas Copco BD+
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
HPD
- Flow
- 300 to 3,200 SCFM (510 to 5,437 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 to -20 °C (-40 to -4 °F)-40 °F/-40 °C (class 2) to -4 °F/-20 °C (class 3)
- ISO 8573-1 class
- Class 2 to 3
- Frequency
- n/a
- Voltages
- n/a
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Heated purgeConditions @100 psig, 100 °FDew point -40 to -20 °C (-40 to -4 °F)ISO class Class 2 to 3
| Model | Flow |
|---|---|
| HPD300 | 300 SCFM510 m³/h |
| HPD400 | 400 SCFM680 m³/h |
| HPD500 | 500 SCFM850 m³/h |
| HPD600 | 600 SCFM1,019 m³/h |
| HPD750 | 750 SCFM1,274 m³/h |
| HPD900 | 900 SCFM1,529 m³/h |
| HPD1050 | 1,050 SCFM1,784 m³/h |
| HPD1300 | 1,300 SCFM2,209 m³/h |
| HPD1500 | 1,500 SCFM2,549 m³/h |
| HPD1800 | 1,800 SCFM3,058 m³/h |
| HPD2200 | 2,200 SCFM3,738 m³/h |
| HPD2600 | 2,600 SCFM4,417 m³/h |
| HPD3200 | 3,200 SCFM5,437 m³/h |
Comparable lines (8)
- Kaeser KED
- Deltech RP
- Ingersoll Rand EH
- Sullair SAH
- Altec AIR HRE
- Mattei MEH
- Champion XCHP
- Nano Purification D5 EH (US)
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
Equivalent equipment at Onyx M3
Purestream (Friulair) refrigerated dryers, distributed by Onyx M3 Inc.
Is your product missing?
Request received. We will proceed within 72 hours.