Comparison · Air dryers

CompAir air dryers

4 refrigerated, desiccant lines (non-cycling, variable speed (vsd), heatless), from the manufacturer’s brochures.

Under construction. This comparison tool is still being built: do not base a purchasing decision on this data. Always confirm with your local distributors.

CD

NON-CYC ISO 4 Europe / international 50 Hz

Recorded wording: CD (F/FW)

Flow
25 to 23,000 m³/h (≈ 15 to 13,537 SCFM)at the manufacturer’s reference conditions (calc. from 0.42–383.33 m³/min)
Dew point
3 °C (37.4 °F)ISO class 4 (+3 °C PDP)
ISO 8573-1 class
Class 4
Frequency
50 Hz
Voltages
230/1/50 · 400/3/50
CSA · CRN
n/a · n/a

Models

All models: Type Non-cyclingDew point 3 °C (37.4 °F)ISO class Class 4

Model Flow Voltage
CD4FCD (F) ≈ 15 SCFM25.2 m³/h 230/1/50
CD7FCD (F) ≈ 25 SCFM42 m³/h 230/1/50
CD9FCD (F) ≈ 32 SCFM54 m³/h 230/1/50
CD12FCD (F) ≈ 42 SCFM72 m³/h 230/1/50
CD18FCD (F) ≈ 64 SCFM108 m³/h 230/1/50
CD24FCD (F) ≈ 85 SCFM144 m³/h 230/1/50
CD30FCD (F) ≈ 106 SCFM180 m³/h 230/1/50
CD37FCD (F) ≈ 132 SCFM225 m³/h 230/1/50
CD43FCD (F) ≈ 153 SCFM259.8 m³/h 230/1/50
CD50FCD (F) ≈ 177 SCFM300 m³/h 230/1/50
CD60FCD (F) ≈ 212 SCFM360 m³/h 230/1/50
CD80FCD (F) ≈ 283 SCFM480 m³/h 230/1/50
CD100FCD (F) ≈ 353 SCFM600 m³/h 230/1/50
CD100FWCD (FW) ≈ 353 SCFM600 m³/h 230/1/50
CD130FCD (F) ≈ 459 SCFM780 m³/h 400/3/50
CD130FWCD (FW) ≈ 459 SCFM780 m³/h 400/3/50
CD160FCD (F) ≈ 559 SCFM949.8 m³/h 400/3/50
CD160FWCD (FW) ≈ 559 SCFM949.8 m³/h 400/3/50
CD216FCD (F) ≈ 765 SCFM1,300.2 m³/h 400/3/50
CD216FWCD (FW) ≈ 765 SCFM1,300.2 m³/h 400/3/50
CD250FCD (F) ≈ 883 SCFM1,500 m³/h 400/3/50
CD250FWCD (FW) ≈ 883 SCFM1,500 m³/h 400/3/50
CD300FCD (F) ≈ 1,059 SCFM1,800 m³/h 400/3/50
CD300FWCD (FW) ≈ 1,059 SCFM1,800 m³/h 400/3/50
CD375FCD (F) ≈ 1,324 SCFM2,250 m³/h 400/3/50
CD375FWCD (FW) ≈ 1,324 SCFM2,250 m³/h 400/3/50
CD430FCD (F) ≈ 1,530 SCFM2,599.8 m³/h 400/3/50
CD430FWCD (FW) ≈ 1,530 SCFM2,599.8 m³/h 400/3/50
CDA533FCD (F) ≈ 1,883 SCFM3,199.8 m³/h 400/3/50
CDA533FWCD (FW) ≈ 1,883 SCFM3,199.8 m³/h 400/3/50
CDA700FCD (F) ≈ 2,472 SCFM4,200 m³/h 400/3/50
CDA700FWCD (FW) ≈ 2,472 SCFM4,200 m³/h 400/3/50
CDA800FCD (F) ≈ 2,825 SCFM4,800 m³/h 400/3/50
CDA800FWCD (FW) ≈ 2,825 SCFM4,800 m³/h 400/3/50
CD900FCD (F) ≈ 3,178 SCFM5,400 m³/h 400/3/50
CD900FWCD (FW) ≈ 3,178 SCFM5,400 m³/h 400/3/50
CD1000FCD (F) ≈ 3,531 SCFM6,000 m³/h 400/3/50
CD1000FWCD (FW) ≈ 3,531 SCFM6,000 m³/h 400/3/50
CD1460FCD (F) ≈ 5,180 SCFM8,800.2 m³/h 400/3/50
CD1460FWCD (FW) ≈ 5,180 SCFM8,800.2 m³/h 400/3/50
CD1600FCD (F) ≈ 5,650 SCFM9,600 m³/h 400/3/50
CD1600FWCD (FW) ≈ 5,650 SCFM9,600 m³/h 400/3/50
CD1920FCD (F) ≈ 6,769 SCFM11,500.2 m³/h 400/3/50
CD1920FWCD (FW) ≈ 6,769 SCFM11,500.2 m³/h 400/3/50
CD2920FCD (F) ≈ 10,359 SCFM17,599.8 m³/h 400/3/50
CD2920FWCD (FW) ≈ 10,359 SCFM17,599.8 m³/h 400/3/50
CD3200FCD (F) ≈ 11,301 SCFM19,200 m³/h 400/3/50
CD3200FWCD (FW) ≈ 11,301 SCFM19,200 m³/h 400/3/50
CD3840FCD (F) ≈ 13,537 SCFM22,999.8 m³/h 400/3/50
CD3840FWCD (FW) ≈ 13,537 SCFM22,999.8 m³/h 400/3/50
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

CD-VS

VSD ISO 4 ≈ Europe / international 50 Hz
Flow
1,260 to 17,664 m³/h (≈ 742 to 10,397 SCFM)at the manufacturer’s reference conditions
Dew point
3 °C (37.4 °F)PDP 3 °C
ISO 8573-1 class
Class 4 (derived)
Frequency
50 Hz (60 Hz : on request)
Voltages
400/3/50
CSA · CRN
n/a · n/a

Models

All models: Type Variable speed (VSD)Dew point 3 °C (37.4 °F)ISO class Class 4 (derived)

Model Flow Voltage
CD30VS 1.1 SCFM1.8 m³/h 3/400/50-60
CD36VS 1.3 SCFM2.2 m³/h 3/400/50-60
CD40VS 1.4 SCFM2.4 m³/h 3/400/50-60
CD50VS 1.8 SCFM3 m³/h 3/400/50-60
CD60VS 2.1 SCFM3.6 m³/h 3/400/50-60
CD72VS 2.6 SCFM4.4 m³/h 3/400/50-60
CD90VS 3.2 SCFM5.4 m³/h 3/400/50
CD110VS 3.9 SCFM6.6 m³/h 3/400/50
CD120VS 4.2 SCFM7.2 m³/h 3/400/50
CD150VS 5.2 SCFM8.8 m³/h 3/400/50
CD21VS 742 SCFM1.3 m³/h 3/400/50-60
Comparable lines (4)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

A-Series AX…NS (modular)

HL ISO 2 ≈ Europe / international
Flow
212 to 1,110 SCFM (360 to 1,885.8 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °C (other PDP options)
ISO 8573-1 class
Class 2 (derived)
Frequency
n/a
Voltages
n/a
CSA · CRN
n/a · n/a

AX_T (twin tower)

HL ISO 1–2 ≈ Europe / international
Flow
400 to 8,500 m³/h (≈ 235 to 5,003 SCFM)at the manufacturer’s reference conditions
Dew point
-70 to -40 °C (-94 to -40 °F)-40 °C (optional -70 °C)
ISO 8573-1 class
Class 1 to 2 (derived)
Frequency
n/a
Voltages
n/a
CSA · CRN
n/a · n/a

Models

All models: Type HeatlessDew point -70 to -40 °C (-94 to -40 °F)ISO class Class 1 to 2 (derived)

Model Flow
AX67TF ≈ 235 SCFM400 m³/h
AX83TF ≈ 294 SCFM500 m³/h
AX125TF ≈ 441 SCFM750 m³/h
AX150TF ≈ 530 SCFM900 m³/h
AX167TL ≈ 589 SCFM1,000 m³/h
AX267TL ≈ 942 SCFM1,600 m³/h
AX333TL ≈ 1,177 SCFM2,000 m³/h
AX417TL ≈ 1,471 SCFM2,500 m³/h
AX550TL ≈ 1,942 SCFM3,300 m³/h
AX767TL ≈ 2,707 SCFM4,600 m³/h
AX933TL ≈ 3,296 SCFM5,600 m³/h
AX1133TL ≈ 4,002 SCFM6,800 m³/h
AX1417TL ≈ 5,003 SCFM8,500 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

Equivalent equipment at Onyx M3

Purestream (Friulair) refrigerated dryers, distributed by Onyx M3 Inc.