Comparison · Air dryers

Aircel air dryers

3 refrigerated, desiccant lines (non-cycling, heatless), from the manufacturer’s brochures.

Under construction. This comparison tool is still being built: do not base a purchasing decision on this data. Always confirm with your local distributors.

VF / DHT

NON-CYC ISO 5 ≈ North America

Recorded wording: VF non-cycling / DHT high temp.

Flow
10 to 2,000 SCFM (≈ 17 to 3,398 m³/h)at the manufacturer’s reference conditions
Dew point
3.3 °C (37.9 °F)PDP 38 °F
ISO 8573-1 class
Class 5 (derived)
Frequency
n/a
Voltages
208/… (several optional voltages)
CSA · CRN
n/a · n/a
Features
High inlet temperature

Models

All models: ISO class Class 5 (derived)

Model Flow TypeConditionsDew pointVoltage
VF-10VF 10 SCFM≈ 17 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)115-1-60
VF-15VF 15 SCFM≈ 25 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)115-1-60
DHT-20DHT 20 SCFM≈ 34 m³/h Non-cycling · High inlet temperature@175 psig, inlet 180 °F10 to 82.2 °C (50 to 180 °F)115-1-60
VF-25VF 25 SCFM≈ 42 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)115-1-60
VF-40VF 40 SCFM≈ 68 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)115-1-60
DHT-40DHT 40 SCFM≈ 68 m³/h Non-cycling · High inlet temperature@175 psig, inlet 180 °F10 to 82.2 °C (50 to 180 °F)115-1-60
VF-50VF 50 SCFM≈ 85 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)115-1-60
DHT-50DHT 50 SCFM≈ 85 m³/h Non-cycling · High inlet temperature@175 psig, inlet 180 °F10 to 82.2 °C (50 to 180 °F)115-1-60
VF-60VF 60 SCFM≈ 102 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)115-1-60
VF-75VF 75 SCFM≈ 127 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)115-1-60
DHT-75DHT 75 SCFM≈ 127 m³/h Non-cycling · High inlet temperature@175 psig, inlet 180 °F10 to 82.2 °C (50 to 180 °F)115-1-60
VF-100VF 100 SCFM≈ 170 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)115-1-60
DHT-100DHT 100 SCFM≈ 170 m³/h Non-cycling · High inlet temperature@175 psig, inlet 180 °F10 to 82.2 °C (50 to 180 °F)115-1-60
VF-125VF 125 SCFM≈ 212 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)115-1-60
DHT-125DHT 125 SCFM≈ 212 m³/h Non-cycling · High inlet temperature@175 psig, inlet 180 °F10 to 82.2 °C (50 to 180 °F)208/230-1-60
VF-150VF 150 SCFM≈ 255 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)115-1-60
VF-200VF 200 SCFM≈ 340 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)230-1-60
VF-250VF 250 SCFM≈ 425 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)230-1-60
VF-300VF 300 SCFM≈ 510 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)230-1-60
VF-400VF 400 SCFM≈ 680 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)460-3-60
VF-500VF 500 SCFM≈ 850 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)460-3-60
VF-600VF 600 SCFM≈ 1,019 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)460-3-60
VF-800VF 800 SCFM≈ 1,359 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)460-3-60
VF-1000VF 1,000 SCFM≈ 1,699 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)460-3-60
VF-1200VF 1,200 SCFM≈ 2,039 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)460-3-60
VF-1600VF 1,600 SCFM≈ 2,718 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)460-3-60
VF-2000VF 2,000 SCFM≈ 3,398 m³/h Non-cyclingCAGI ADF 100, 100 psig/100 °F3.3 to 37.8 °C (37.9 to 100 °F)460-3-60
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

AES

? ISO 4 North America

Recorded wording: AES digital scroll

Flow
600 to 10,000 SCFM (≈ 1,019 to 16,990 m³/h)at the manufacturer’s reference conditions
Dew point
n/aISO 8573-1 class 4
ISO 8573-1 class
Class 4
Frequency
n/a
Voltages
208/… · 575/… (optional)
CSA · CRN
n/a · n/a
Features
Digital scroll compressor · Energy-saving mode

Models

All models: Type n/a · Digital scroll compressorConditions CAGI ADF 100Dew point 3.3 °C (37.9 °F)ISO class Class 4Voltage 460-3-60

Model Flow
AES-600 600 SCFM≈ 1,019 m³/h
AES-800 800 SCFM≈ 1,359 m³/h
AES-1000 1,000 SCFM≈ 1,699 m³/h
AES-1250 1,250 SCFM≈ 2,124 m³/h
AES-1500 1,500 SCFM≈ 2,549 m³/h
AES-1750 1,750 SCFM≈ 2,973 m³/h
AES-2000 2,000 SCFM≈ 3,398 m³/h
AES-2500 2,500 SCFM≈ 4,248 m³/h
AES-3000 3,000 SCFM≈ 5,097 m³/h
AES-3500 3,500 SCFM≈ 5,947 m³/h
AES-4000 4,000 SCFM≈ 6,796 m³/h
AES-4500 4,500 SCFM≈ 7,646 m³/h
AES-5250 5,000 SCFM≈ 8,495 m³/h
AES-6000 6,000 SCFM≈ 10,194 m³/h
AES-7000 7,000 SCFM≈ 11,893 m³/h
AES-8000 8,000 SCFM≈ 13,592 m³/h
AES-8750 9,000 SCFM≈ 15,291 m³/h
AES-10000 10,000 SCFM≈ 16,990 m³/h
Comparable lines (0)

No comparable line in the current data.

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

AHLD E-Series

HL ISO 1–2 North America
Flow
70 to 8,000 SCFM (≈ 119 to 13,592 m³/h)at the manufacturer’s reference conditions
Dew point
-73.3 to -40 °C (-99.9 to -40 °F)-40 °F (CDP: -100 °F)
ISO 8573-1 class
Class 1 to 2
Frequency
n/a
Voltages
n/a
CSA · CRN
n/a · n/a

Models

All models: Type HeatlessConditions CAGI ADF 200 @100 psig/100 °FDew point -73.3 to -40 °C (-99.9 to -40 °F)ISO class Class 1 to 2

Model Flow
AHLD-70 E 70 SCFM≈ 119 m³/h
AHLD-100 E 100 SCFM≈ 170 m³/h
AHLD-150 E 150 SCFM≈ 255 m³/h
AHLD-200 E 200 SCFM≈ 340 m³/h
AHLD-250 E 250 SCFM≈ 425 m³/h
AHLD-300 E 300 SCFM≈ 510 m³/h
AHLD-350 E 350 SCFM≈ 595 m³/h
AHLD-450 E 450 SCFM≈ 765 m³/h
AHLD-500 E 500 SCFM≈ 850 m³/h
AHLD-600 E 600 SCFM≈ 1,019 m³/h
AHLD-750 E 750 SCFM≈ 1,274 m³/h
AHLD-1000 E 1,000 SCFM≈ 1,699 m³/h
AHLD-1250 E 1,250 SCFM≈ 2,124 m³/h
AHLD-1500 E 1,500 SCFM≈ 2,549 m³/h
AHLD-2000 E 2,000 SCFM≈ 3,398 m³/h
AHLD-2500 E 2,500 SCFM≈ 4,248 m³/h
AHLD-3000 E 3,000 SCFM≈ 5,097 m³/h
AHLD-3500 E 3,500 SCFM≈ 5,947 m³/h
AHLD-4000 E 4,000 SCFM≈ 6,796 m³/h
AHLD-4500 E 4,500 SCFM≈ 7,646 m³/h
AHLD-5000 E 5,000 SCFM≈ 8,495 m³/h
AHLD-6000 E 6,000 SCFM≈ 10,194 m³/h
AHLD-7000 E 7,000 SCFM≈ 11,893 m³/h
AHLD-8000 E 8,000 SCFM≈ 13,592 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

Equivalent equipment at Onyx M3

Purestream (Friulair) refrigerated dryers, distributed by Onyx M3 Inc.

Is your product missing?