Comparison · Air dryers
Nano Purification air dryers
9 refrigerated, desiccant lines (cycling, heatless, heated purge, blower purge), from the manufacturer’s brochures.
Under construction. This comparison tool is still being built: do not base a purchasing decision on this data. Always confirm with your local distributors.
All manufacturers Search by need (refrigerated)Search by need (desiccant)
TMC
Recorded wording: TMC thermal mass cycling (US)
- Flow
- 30 to 635 SCFM (≈ 51 to 1,079 m³/h)at the manufacturer’s reference conditions
- Dew point
- n/aISO class 5
- ISO 8573-1 class
- Class 5
- Frequency
- 60 Hz
- Voltages
- 115/1/60 · 460/3/60
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type CyclingISO class Class 5
| Model | Flow | Voltage |
|---|---|---|
| TMC 0030 N | 30 SCFM≈ 51 m³/h | 115/1/60 |
| TMC 0055 N | 55 SCFM≈ 93 m³/h | 115/1/60 |
| TMC 0075 N | 75 SCFM≈ 127 m³/h | 115/1/60 |
| TMC 0105 N | 105 SCFM≈ 178 m³/h | 115/1/60 |
| TMC 0130 N | 130 SCFM≈ 221 m³/h | 115/1/60 |
| TMC 0170 N | 170 SCFM≈ 289 m³/h | 115/1/60 |
| TMC 0200 N | 200 SCFM≈ 340 m³/h | 230/1/60 |
| TMC 0265 N | 265 SCFM≈ 450 m³/h | 230/1/60 |
| TMC 0320 N | 320 SCFM≈ 544 m³/h | 460/3/60 |
| TMC 0400 N | 400 SCFM≈ 680 m³/h | 460/3/60 |
| TMC 0510 N | 510 SCFM≈ 866 m³/h | 460/3/60 |
| TMC 0635 N | 635 SCFM≈ 1,079 m³/h | 460/3/60 |
Comparable lines (8)
- MTA DE iTECH
- Purestream (Friulair) ACT ES
- Sullair SRN / SRD
- Gardner Denver GDDF-ES
- Kaeser SECOTEC TA / TB / TC
- Sullivan-Palatek SPR
- Pneumatech AC VSD
- ZEKS HeatSink HSH/HSG 300-1600
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
D1 (undefined)
Recorded wording: D1
- Flow
- 3 to 560 SCFM (≈ 5 to 951 m³/h)at the manufacturer’s reference conditions
- Dew point
- -70 to -40 °C (-94 to -40 °F)-40 °F (class 1 -94 °F optional)
- ISO 8573-1 class
- Class 1 to 2
- Frequency
- 50 Hz · 60 Hz
- Voltages
- 85-264 VAC 50/60 Hz (optional 24 VDC)
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessConditions @100 psig, 100 °F, PDP -40 °FDew point -70 to -40 °C (-94 to -40 °F)ISO class Class 1 to 2Voltage 85-264 VAC 50/60 Hz (optional 24 VDC)
| Model | Flow |
|---|---|
| NDL 010 | 3 SCFM≈ 5 m³/h |
| NDL 020 | 5 SCFM≈ 8 m³/h |
| NDL 030 | 10 SCFM≈ 17 m³/h |
| NDL 040 | 15 SCFM≈ 25 m³/h |
| NDL 050 | 20 SCFM≈ 34 m³/h |
| NDL 060N | 34 SCFM≈ 58 m³/h |
| NDL 070N | 41 SCFM≈ 70 m³/h |
| NDL 080N | 53 SCFM≈ 90 m³/h |
| NDL 090N | 66 SCFM≈ 112 m³/h |
| NDL 100N | 88 SCFM≈ 150 m³/h |
| NDL 110N | 106 SCFM≈ 180 m³/h |
| NDL 120N | 132 SCFM≈ 224 m³/h |
| NDL 130N | 177 SCFM≈ 301 m³/h |
| NDL 2110N | 212 SCFM≈ 360 m³/h |
| NDL 2120N | 276 SCFM≈ 469 m³/h |
| NDL 2130N | 400 SCFM≈ 680 m³/h |
| NDL 3130N | 560 SCFM≈ 951 m³/h |
Comparable lines (8)
- Mattei DD 10-6130
- MARK ADS 1-156
- Donaldson Ultrapac 2000 Midi
- Quincy QMOD (modular)
- Mikropor MMD / MMD HC (modular)
- Sullair DMD (modular)
- Parker PNEUDRI MIDIplus
- Hertz Kompressoren HHD 16-20 bar
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
D5 HL (US)
- Flow
- 70 to 3,000 SCFM (≈ 119 to 5,097 m³/h)at the manufacturer’s reference conditions
- Dew point
- -70 to -40 °C (-94 to -40 °F)-40 °F (optional -94 °F)
- ISO 8573-1 class
- Class 2
- Frequency
- 60 Hz
- Voltages
- 115/1/60 (optional 230/1/60, 12 VDC)
- CSA · CRN
- UL/cUL 508A · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessConditions @100 psig, 100 °F, PDP -40 °FDew point -70 to -40 °C (-94 to -40 °F)ISO class Class 2Voltage 115/1/60 (optional 230/1/60, 12 VDC)
| Model | Flow |
|---|---|
| HL 0070 | 70 SCFM≈ 119 m³/h |
| HL 0100 | 100 SCFM≈ 170 m³/h |
| HL 0150 | 150 SCFM≈ 255 m³/h |
| HL 0200 | 200 SCFM≈ 340 m³/h |
| HL 0250 | 250 SCFM≈ 425 m³/h |
| HL 0300 | 300 SCFM≈ 510 m³/h |
| HL 0350 | 350 SCFM≈ 595 m³/h |
| HL 0450 | 450 SCFM≈ 765 m³/h |
| HL 0500 | 500 SCFM≈ 850 m³/h |
| HL 0600 | 600 SCFM≈ 1,019 m³/h |
| HL 0750 | 750 SCFM≈ 1,274 m³/h |
| HL 1000 | 1,000 SCFM≈ 1,699 m³/h |
| HL 1250 | 1,250 SCFM≈ 2,124 m³/h |
| HL 1500 | 1,500 SCFM≈ 2,549 m³/h |
| HL 2000 | 2,000 SCFM≈ 3,398 m³/h |
| HL 2500 | 2,500 SCFM≈ 4,248 m³/h |
| HL 3000 | 3,000 SCFM≈ 5,097 m³/h |
Comparable lines (8)
- Champion CDT
- Gardner Denver DGH
- Hankison HHX
- Hankison HHE
- Hankison HHS
- Hankison HHL
- Kaeser KAD
- BEKO Technologies DRYPOINT XCp
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
D5 HL
- Flow
- 216 to 5,760 m³/h (≈ 127 to 3,390 SCFM)at the manufacturer’s reference conditions
- Dew point
- -70 to -40 °C (-94 to -40 °F)-40 °C (optional -70 °C)
- ISO 8573-1 class
- Class 1 to 2 (derived)
- Frequency
- 50 Hz
- Voltages
- n/a
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessConditions FAD 7 bar, inlet 35 °C, ambient 25 °CDew point -70 to -40 °C (-94 to -40 °F)ISO class Class 1 to 2 (derived)
| Model | Flow |
|---|---|
| HL 125 | ≈ 127 SCFM216 m³/h |
| HL 200 | ≈ 191 SCFM324 m³/h |
| HL 275 | ≈ 275 SCFM468 m³/h |
| HL 380 | ≈ 381 SCFM648 m³/h |
| HL 465 | ≈ 466 SCFM792 m³/h |
| HL 635 | ≈ 636 SCFM1,080 m³/h |
| HL 760 | ≈ 763 SCFM1,296 m³/h |
| HL 1020 | ≈ 1,017 SCFM1,728 m³/h |
| HL 1330 | ≈ 1,335 SCFM2,268 m³/h |
| HL 1690 | ≈ 1,695 SCFM2,880 m³/h |
| HL 2060 | ≈ 2,055 SCFM3,492 m³/h |
| HL 2670 | ≈ 2,670 SCFM4,536 m³/h |
| HL 3390 | ≈ 3,390 SCFM5,760 m³/h |
Comparable lines (8)
- Gardner Denver XGHL
- Ingersoll Rand HL
- ZEKS Eclipse ZPB
- Van Air Systems HL
- OMI HLA PRO
- Ingersoll Rand D…ILA
- Hertz Kompressoren HDA
- ALUP AD 650-1300 (sensor)
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
D5 BP (US)
- Flow
- 250 to 6,000 SCFM (≈ 425 to 10,194 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °F
- ISO 8573-1 class
- Class 2
- Frequency
- 60 Hz
- Voltages
- 460 VAC/60 Hz
- CSA · CRN
- UL/cUL 508A · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Blower purgeConditions @100 psig, 100 °F, PDP -40 °FDew point -40 °C (-40 °F)ISO class Class 2Voltage 460 VAC/60 Hz
| Model | Flow |
|---|---|
| BP 0250 | 250 SCFM≈ 425 m³/h |
| BP 0350 | 350 SCFM≈ 595 m³/h |
| BP 0500 | 500 SCFM≈ 850 m³/h |
| BP 0600 | 600 SCFM≈ 1,019 m³/h |
| BP 0800 | 800 SCFM≈ 1,359 m³/h |
| BP 1000 | 1,000 SCFM≈ 1,699 m³/h |
| BP 1200 | 1,200 SCFM≈ 2,039 m³/h |
| BP 1400 | 1,400 SCFM≈ 2,379 m³/h |
| BP 1600 | 1,600 SCFM≈ 2,718 m³/h |
| BP 2000 | 2,000 SCFM≈ 3,398 m³/h |
| BP 2500 | 2,500 SCFM≈ 4,248 m³/h |
| BP 3000 | 3,000 SCFM≈ 5,097 m³/h |
| BP 3500 | 3,500 SCFM≈ 5,947 m³/h |
| BP 4000 | 4,000 SCFM≈ 6,796 m³/h |
| BP 5000 | 5,000 SCFM≈ 8,495 m³/h |
| BP 6000 | 6,000 SCFM≈ 10,194 m³/h |
Comparable lines (8)
- Atlas Copco BD+
- Atlas Copco BD+ ZP
- Ingersoll Rand HB
- Mattei MBP
- Hankison HBP
- Kaeser KBD
- Pneumatic Products (SPX) IBP
- Ingersoll Rand D…IBA
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
D5 BP
- Flow
- 1,188 to 10,800 m³/h (≈ 699 to 6,357 SCFM)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °C
- ISO 8573-1 class
- Class 2 (derived)
- Frequency
- 50 Hz
- Voltages
- n/a
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Blower purgeConditions FAD 7 bar, inlet 35 °C, ambient 25 °CDew point -40 °C (-40 °F)ISO class Class 2 (derived)
| Model | Flow |
|---|---|
| BP 760 | ≈ 699 SCFM1,188 m³/h |
| BP 1020 | ≈ 848 SCFM1,440 m³/h |
| BP 1330 | ≈ 1,165 SCFM1,980 m³/h |
| BP 1690 | ≈ 1,801 SCFM3,060 m³/h |
| BP 2060 | ≈ 2,055 SCFM3,492 m³/h |
| BP 2670 | ≈ 2,331 SCFM3,960 m³/h |
| BP 3390 | ≈ 2,966 SCFM5,040 m³/h |
| BP 4400 | ≈ 3,814 SCFM6,480 m³/h |
| BP 5360 | ≈ 4,662 SCFM7,920 m³/h |
| BP 6350 | ≈ 5,361 SCFM9,108 m³/h |
| BP 7300 | ≈ 6,357 SCFM10,800 m³/h |
Comparable lines (8)
- BEKO Technologies EVERDRY FRL (North America)
- BEKO Technologies DRYPOINT XFe
- BEKO Technologies DRYPOINT XFi
- Sullivan-Palatek SPDPHB Pro Heated Blower Purge
- Sullivan-Palatek SPDPRHB Premium Heated Blower Purge
- BEKO Technologies EVERDRY FRP
- Sullair SAV
- Pneumatech PB 760-7400 HE
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
D5 BP ZP (zero purge)
- Flow
- 1,188 to 10,800 m³/h (≈ 699 to 6,357 SCFM)at the manufacturer’s reference conditions
- Dew point
- -70 to -40 °C (-94 to -40 °F)-40 °C (optional -70 °C)
- ISO 8573-1 class
- Class 1 to 2 (derived)
- Frequency
- 50 Hz
- Voltages
- n/a
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Blower purgeConditions FAD 7 bar, inlet 35 °C, ambient 25 °CDew point -70 to -40 °C (-94 to -40 °F)ISO class Class 1 to 2 (derived)
| Model | Flow |
|---|---|
| BP 760 ZP | ≈ 699 SCFM1,188 m³/h |
| BP 1020 ZP | ≈ 848 SCFM1,440 m³/h |
| BP 1330 ZP | ≈ 1,165 SCFM1,980 m³/h |
| BP 1690 ZP | ≈ 1,801 SCFM3,060 m³/h |
| BP 2060 ZP | ≈ 2,055 SCFM3,492 m³/h |
| BP 2670 ZP | ≈ 2,331 SCFM3,960 m³/h |
| BP 3390 ZP | ≈ 2,966 SCFM5,040 m³/h |
| BP 4400 ZP | ≈ 3,814 SCFM6,480 m³/h |
| BP 5360 ZP | ≈ 4,662 SCFM7,920 m³/h |
| BP 6350 ZP | ≈ 5,361 SCFM9,108 m³/h |
| BP 7300 ZP | ≈ 6,357 SCFM10,800 m³/h |
Comparable lines (4)
- BEKO Technologies EVERDRY FRL (North America)
- Pneumatech PB 760-7400 HE
- Atlas Copco BD+
- Atlas Copco BD+ ZP
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
D5 EH (US)
- Flow
- 150 to 3,000 SCFM (≈ 255 to 5,097 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °F
- ISO 8573-1 class
- Class 2
- Frequency
- 60 Hz
- Voltages
- 460/3/60 (optional 575/3/60)
- CSA · CRN
- UL/cUL 508A · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Heated purgeConditions @100 psig, 100 °F, PDP -40 °FDew point -40 °C (-40 °F)ISO class Class 2Voltage 460/3/60 (optional 575/3/60)
| Model | Flow |
|---|---|
| EH 0150 | 150 SCFM≈ 255 m³/h |
| EH 0250 | 250 SCFM≈ 425 m³/h |
| EH 0350 | 350 SCFM≈ 595 m³/h |
| EH 0500 | 500 SCFM≈ 850 m³/h |
| EH 0750 | 750 SCFM≈ 1,274 m³/h |
| EH 1000 | 1,000 SCFM≈ 1,699 m³/h |
| EH 1250 | 1,250 SCFM≈ 2,124 m³/h |
| EH 1500 | 1,500 SCFM≈ 2,549 m³/h |
| EH 2000 | 2,000 SCFM≈ 3,398 m³/h |
| EH 2500 | 2,500 SCFM≈ 4,248 m³/h |
| EH 3000 | 3,000 SCFM≈ 5,097 m³/h |
Comparable lines (8)
- Champion XCHP
- Mattei MEH
- MTA DryXtreme NST
- Altec AIR HRE
- Sullivan-Palatek SPDH Pro Heated Purge
- Sullivan-Palatek SPDHR Premium Heated Purge
- BEKO Technologies DRYPOINT ACH
- Deltech RP
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
D5 EH
- Flow
- 1,188 to 10,800 m³/h (≈ 699 to 6,357 SCFM)at the manufacturer’s reference conditions
- Dew point
- -70 to -40 °C (-94 to -40 °F)-40 °C (optional -70 °C)
- ISO 8573-1 class
- Class 1 to 2 (derived)
- Frequency
- 50 Hz
- Voltages
- n/a
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Heated purgeConditions FAD 7 bar, inlet 35 °C, ambient 25 °CDew point -70 to -40 °C (-94 to -40 °F)ISO class Class 1 to 2 (derived)
Comparable lines (1)
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
Equivalent equipment at Onyx M3
Purestream (Friulair) refrigerated dryers, distributed by Onyx M3 Inc.
Is your product missing?
Request received. We will proceed within 72 hours.