Comparison · Air dryers
Sullair air dryers
5 refrigerated, desiccant lines (non-cycling, cycling, blower purge, heated purge, heatless), from the manufacturer’s brochures.
Under construction. This comparison tool is still being built: do not base a purchasing decision on this data. Always confirm with your local distributors.
All manufacturers Search by need (refrigerated)Search by need (desiccant)
SRN / SRD
Recorded wording: SRN non-cycling / SRD cycling
- Flow
- 10 to 6,000 SCFM (≈ 17 to 10,194 m³/h)at the manufacturer’s reference conditions
- Dew point
- 2.8 to 7.2 °C (37 to 45 °F)PDP 37–45 °F; ISO 8573-1 class 4–5
- ISO 8573-1 class
- Class 4 to 5
- Frequency
- 60 Hz
- Voltages
- 115V · 230V · 460V · 575V
- CSA · CRN
- yes (UL/CSA) · yes (exchangers ASME/CRN)
- Sources
- Manufacturer’s page
Models
All models: Dew point 2.8 to 7.2 °C (37 to 45 °F)ISO class Class 4 to 5
| Model | Flow | Type | Voltage |
|---|---|---|---|
| SRN-10SRN | 10 SCFM≈ 17 m³/h | Non-cycling | 115V/1/60 |
| SRN-15SRN | 15 SCFM≈ 25 m³/h | Non-cycling | 115V/1/60 |
| SRN-25SRN | 25 SCFM≈ 42 m³/h | Non-cycling | 115V/1/60 |
| SRN-35SRN | 35 SCFM≈ 59 m³/h | Non-cycling | 115V/1/60 |
| SRN-50SRN | 50 SCFM≈ 85 m³/h | Non-cycling | 115V/1/60 |
| SRN-75SRN | 75 SCFM≈ 127 m³/h | Non-cycling | 115V/1/60 ; 230V/1/60 |
| SRD-75SRD | 75 SCFM≈ 127 m³/h | Cycling | 115V/1/60 |
| SRN-100SRN | 100 SCFM≈ 170 m³/h | Non-cycling | 115V/1/60 ; 230V/1/60 |
| SRD-100SRD | 100 SCFM≈ 170 m³/h | Cycling | 115V/1/60 |
| SRN-125SRN | 125 SCFM≈ 212 m³/h | Non-cycling | 115V/1/60 ; 230V/1/60 |
| SRD-125SRD | 125 SCFM≈ 212 m³/h | Cycling | 115V/1/60 |
| SRN-150SRN | 150 SCFM≈ 255 m³/h | Non-cycling | 115V/1/60 ; 230V/1/60 |
| SRD-150SRD | 150 SCFM≈ 255 m³/h | Cycling | 115V/1/60 |
| SRN-175SRN | 175 SCFM≈ 297 m³/h | Non-cycling | 115V/1/60 ; 230V/1/60 |
| SRD-175SRD | 175 SCFM≈ 297 m³/h | Cycling | 115V/1/60 ; 230V/1/60 |
| SRN-200SRN | 200 SCFM≈ 340 m³/h | Non-cycling | 230V/1/60 |
| SRD-200SRD | 200 SCFM≈ 340 m³/h | Cycling | 230V/1/60 |
| SRN-250SRN | 250 SCFM≈ 425 m³/h | Non-cycling | 230V/1/60 |
| SRD-250SRD | 250 SCFM≈ 425 m³/h | Cycling | 230V/1/60 |
| SRN-325SRN | 325 SCFM≈ 552 m³/h | Non-cycling | 460V/3/60 ; 575V/3/60 |
| SRD-325SRD | 325 SCFM≈ 552 m³/h | Cycling | 460V/3/60 ; 575V/3/60 |
| SRN-400SRN | 400 SCFM≈ 680 m³/h | Non-cycling | 460V/3/60 ; 575V/3/60 |
| SRD-400SRD | 400 SCFM≈ 680 m³/h | Cycling | 460V/3/60 ; 575V/3/60 |
| SRN-500SRN | 500 SCFM≈ 850 m³/h | Non-cycling | 460V/3/60 ; 575V/3/60 |
| SRD-500SRD | 500 SCFM≈ 850 m³/h | Cycling | 460V/3/60 ; 575V/3/60 |
| SRN-700SRN | 700 SCFM≈ 1,189 m³/h | Non-cycling | 460V/3/60 ; 575V/3/60 |
| SRD-700SRD | 700 SCFM≈ 1,189 m³/h | Cycling | 460V/3/60 ; 575V/3/60 |
| SRN-800SRN | 800 SCFM≈ 1,359 m³/h | Non-cycling | 460V/3/60 ; 575V/3/60 |
| SRD-800SRD | 800 SCFM≈ 1,359 m³/h | Cycling | 460V/3/60 ; 575V/3/60 |
| SRN-1000SRN | 1,000 SCFM≈ 1,699 m³/h | Non-cycling | 460V/3/60 ; 575V/3/60 |
| SRD-1000SRD | 1,000 SCFM≈ 1,699 m³/h | Cycling | 460V/3/60 ; 575V/3/60 |
| SRN-1400SRN | 1,400 SCFM≈ 2,379 m³/h | Non-cycling | 460V/3/60 ; 575V/3/60 |
| SRD-1400SRD | 1,400 SCFM≈ 2,379 m³/h | Cycling | 460V/3/60 ; 575V/3/60 |
| SRN-1600SRN | 1,600 SCFM≈ 2,718 m³/h | Non-cycling | 460V/3/60 ; 575V/3/60 |
| SRD-1600SRD | 1,600 SCFM≈ 2,718 m³/h | Cycling | 460V/3/60 ; 575V/3/60 |
| SRN-2000SRN | 2,000 SCFM≈ 3,398 m³/h | Non-cycling | 460V/3/60 ; 575V/3/60 |
| SRD-2000SRD | 2,000 SCFM≈ 3,398 m³/h | Cycling | 460V/3/60 ; 575V/3/60 |
| SRN-2400SRN | 2,400 SCFM≈ 4,078 m³/h | Non-cycling | 460V/3/60 ; 575V/3/60 |
| SRD-2400SRD | 2,400 SCFM≈ 4,078 m³/h | Cycling | 460V/3/60 ; 575V/3/60 |
| SRN-3000SRN | 3,000 SCFM≈ 5,097 m³/h | Non-cycling | 460V/3/60 ; 575V/3/60 |
| SRD-3000SRD | 3,000 SCFM≈ 5,097 m³/h | Cycling | 460V/3/60 ; 575V/3/60 |
| SRN-3800SRN | 3,800 SCFM≈ 6,456 m³/h | Non-cycling | 460V/3/60 ; 575V/3/60 |
| SRD-3800SRD | 3,800 SCFM≈ 6,456 m³/h | Cycling | 460V/3/60 ; 575V/3/60 |
| SRN-5000SRN | 5,000 SCFM≈ 8,495 m³/h | Non-cycling | 460V/3/60 ; 575V/3/60 |
| SRD-5000SRD | 5,000 SCFM≈ 8,495 m³/h | Cycling | 460V/3/60 ; 575V/3/60 |
| SRN-6000SRN | 6,000 SCFM≈ 10,194 m³/h | Non-cycling | 460V/3/60 ; 575V/3/60 |
| SRD-6000SRD | 6,000 SCFM≈ 10,194 m³/h | Cycling | 460V/3/60 ; 575V/3/60 |
Comparable lines (8)
- Mikropor MKE
- BEKO Technologies DRYPOINT RX / RA
- Purestream (Friulair) FCT
- Purestream (Friulair) ACT (→ FCT)
- Gardner Denver GDDF-ES
- Atlas Copco FX 1-21
- Mattei MD Ecologic
- Gardner Denver XGNC
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
DMD (modular)
- Flow
- 3 to 240 SCFM (≈ 5 to 408 m³/h)at the manufacturer’s reference conditions
- Dew point
- -73 to -20 °C (-99.4 to -4 °F)-40 °F std (options -4 °F/-20 °C or -100 °F/-73 °C)
- ISO 8573-1 class
- Classes 1, 2, 3 (derived)
- Frequency
- 50 Hz · 60 Hz
- Voltages
- 115–230V/1PH
- CSA · CRN
- cULus (control panel) · yes (ASME/CRN)
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessDew point -73 to -20 °C (-99.4 to -4 °F)ISO class Classes 1, 2, 3 (derived)Voltage 115–230V/1PH
| Model | Flow |
|---|---|
| DMD-3 | 3 SCFM≈ 5 m³/h |
| DMD-5 | 5 SCFM≈ 8 m³/h |
| DMD-10 | 10 SCFM≈ 17 m³/h |
| DMD-15 | 15 SCFM≈ 25 m³/h |
| DMD-20 | 20 SCFM≈ 34 m³/h |
| DMD-25 | 25 SCFM≈ 42 m³/h |
| DMD-30 | 30 SCFM≈ 51 m³/h |
| DMD-40 | 40 SCFM≈ 68 m³/h |
| DMD-50 | 50 SCFM≈ 85 m³/h |
| DMD-60 | 60 SCFM≈ 102 m³/h |
| DMD-75 | 75 SCFM≈ 127 m³/h |
| DMD-100 | 100 SCFM≈ 170 m³/h |
| DMD-120 | 120 SCFM≈ 204 m³/h |
| DMD-180 | 180 SCFM≈ 306 m³/h |
| DMD-240 | 240 SCFM≈ 408 m³/h |
Comparable lines (8)
- Deltech DHDM (modular)
- Hankison PHDM (modular)
- ZEKS ZMA (modular)
- Ingersoll Rand DA…IM (modular)
- BEKO Technologies DRYPOINT ACC
- Donaldson Ultrapac 2000 Midi
- Mattei DD 10-6130
- Nano Purification D1 (undefined)
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
SA
- Flow
- 55 to 3,000 SCFM (≈ 93 to 5,097 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °F/-40 °C
- ISO 8573-1 class
- Class 2 (derived)
- Frequency
- 50 Hz · 60 Hz
- Voltages
- 120V/1PH
- CSA · CRN
- yes (ETL UL/CSA) · yes (ASME/CRN)
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessDew point -40 °C (-40 °F)ISO class Class 2 (derived)Voltage 120V/1PH
| Model | Flow |
|---|---|
| SA55 | 55 SCFM≈ 93 m³/h |
| SA100 | 100 SCFM≈ 170 m³/h |
| SA130 | 130 SCFM≈ 221 m³/h |
| SA200 | 200 SCFM≈ 340 m³/h |
| SA250 | 250 SCFM≈ 425 m³/h |
| SA300 | 300 SCFM≈ 510 m³/h |
| SA400 | 400 SCFM≈ 680 m³/h |
| SA500 | 500 SCFM≈ 850 m³/h |
| SA600 | 600 SCFM≈ 1,019 m³/h |
| SA800 | 800 SCFM≈ 1,359 m³/h |
| SA1000 | 1,000 SCFM≈ 1,699 m³/h |
| SA1200 | 1,200 SCFM≈ 2,039 m³/h |
| SA1500 | 1,500 SCFM≈ 2,549 m³/h |
| SA2000 | 2,000 SCFM≈ 3,398 m³/h |
| SA2600 | 2,600 SCFM≈ 4,417 m³/h |
| SA3000 | 3,000 SCFM≈ 5,097 m³/h |
Comparable lines (8)
- Atlas Copco CD+ 110-300
- Pneumatech PH 230-635 HE
- Nano Purification D5 HL (US)
- Champion CDT
- Gardner Denver DGH
- Hankison HHX
- Hankison HHE
- Hankison HHS
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
SAV
- Flow
- 500 to 7,500 SCFM (≈ 850 to 12,743 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °F/-40 °C
- ISO 8573-1 class
- Class 2 (derived)
- Frequency
- 50 Hz · 60 Hz
- Voltages
- 460V/3PH (optional 575/3/60)
- CSA · CRN
- yes (ETL UL/CSA) · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Blower purgeDew point -40 °C (-40 °F)ISO class Class 2 (derived)Voltage 460V/3PH (optional 575/3/60)
| Model | Flow |
|---|---|
| SAV500 | 500 SCFM≈ 850 m³/h |
| SAV600 | 600 SCFM≈ 1,019 m³/h |
| SAV800 | 800 SCFM≈ 1,359 m³/h |
| SAV1000 | 1,000 SCFM≈ 1,699 m³/h |
| SAV1200 | 1,200 SCFM≈ 2,039 m³/h |
| SAV1500 | 1,500 SCFM≈ 2,549 m³/h |
| SAV2000 | 2,000 SCFM≈ 3,398 m³/h |
| SAV2600 | 2,600 SCFM≈ 4,417 m³/h |
| SAV3000 | 3,000 SCFM≈ 5,097 m³/h |
| SAV4000 | 4,000 SCFM≈ 6,796 m³/h |
| SAV5000 | 5,000 SCFM≈ 8,495 m³/h |
| SAV6000 | 6,000 SCFM≈ 10,194 m³/h |
| SAV7500 | 7,500 SCFM≈ 12,743 m³/h |
Comparable lines (8)
- BEKO Technologies EVERDRY FRP
- BEKO Technologies EVERDRY FRL (North America)
- Nano Purification D5 BP
- Nano Purification D5 BP ZP (zero purge)
- Mattei DDH 850-10800
- BEKO Technologies DRYPOINT XFe
- BEKO Technologies DRYPOINT XFi
- Sullivan-Palatek SPDPHB Pro Heated Blower Purge
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
SAH
- Flow
- 500 to 3,000 SCFM (≈ 850 to 5,097 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °F/-40 °C
- ISO 8573-1 class
- Class 2 (derived)
- Frequency
- 50 Hz · 60 Hz
- Voltages
- 480V/3PH (optional 575/3/60)
- CSA · CRN
- yes (ETL UL/CSA) · yes (ASME/CRN)
- Sources
- Manufacturer’s page
Models
All models: Type Heated purgeDew point -40 °C (-40 °F)ISO class Class 2 (derived)Voltage 480V/3PH (optional 575/3/60)
Comparable lines (8)
- Ingersoll Rand EH
- Hankison HPD
- Kaeser KED
- Atlas Copco AD 360-1600
- Deltech RP
- Quincy QHP
- Altec AIR HRE
- Nano Purification D5 EH
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.