Comparison · Air dryers
BEKO Technologies air dryers
17 refrigerated, desiccant lines (non-cycling, heatless, blower purge, heated purge, heat of compression (hoc)), from the manufacturer’s brochures.
Under construction. This comparison tool is still being built: do not base a purchasing decision on this data. Always confirm with your local distributors.
All manufacturers Search by need (refrigerated)Search by need (desiccant)
DRYPOINT RA III
Recorded wording: DRYPOINT RA III (intl)
- Flow
- 10 to 1,700 SCFM (20 to 3,000 m³/h)at the manufacturer’s reference conditions
- Dew point
- 3 °C (37.4 °F)PDP +3 °C (base volume)
- ISO 8573-1 class
- Class 4 (derived)
- Frequency
- 50 Hz · 60 Hz
- Voltages
- n/a
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Non-cyclingDew point 3 °C (37.4 °F)ISO class Class 4 (derived)
| Model | Flow | Voltage |
|---|---|---|
| DRYPOINT RA III 20 AC | ≈ 12 SCFM21 m³/h | 230/1/50-60 |
| DRYPOINT RA III 35 AC | ≈ 19 SCFM33 m³/h | 230/1/50-60 |
| DRYPOINT RA III 50 AC | ≈ 30 SCFM51 m³/h | 230/1/50-60 |
| DRYPOINT RA III 70 AC | ≈ 42 SCFM72 m³/h | 230/1/50-60 |
| DRYPOINT RA III 110 AC | ≈ 64 SCFM108 m³/h | 230/1/50-60 |
| DRYPOINT RA III 135 AC | ≈ 81 SCFM138 m³/h | 230/1/50-60 |
| DRYPOINT RA III 190 AC | ≈ 109 SCFM186 m³/h | 230/1/50-60 |
| DRYPOINT RA III 240 AC | ≈ 141 SCFM240 m³/h | 230/1/50-60 |
| DRYPOINT RA III 330 AC | ≈ 194 SCFM330 m³/h | 230/1/50-60 |
| DRYPOINT RA III 370 AC | ≈ 219 SCFM372 m³/h | 230/1/50 |
| DRYPOINT RA III 490 AC | ≈ 286 SCFM486 m³/h | 230/1/50 |
| DRYPOINT RA III 630 AC | ≈ 371 SCFM630 m³/h | 230/1/50 |
| DRYPOINT RA III 750 AC | ≈ 441 SCFM750 m³/h | 230/1/50 |
| DRYPOINT RA III 750 WC | ≈ 441 SCFM750 m³/h | 230/1/50 |
| DRYPOINT RA III 870 AC | ≈ 512 SCFM870 m³/h | 230/1/50 |
| DRYPOINT RA III 870 WC | ≈ 512 SCFM870 m³/h | 230/1/50 |
| DRYPOINT RA III 960 AC | ≈ 565 SCFM960 m³/h | 230/1/50 |
| DRYPOINT RA III 960 WC | ≈ 565 SCFM960 m³/h | 230/1/50 |
| DRYPOINT RA III 1080 AC | ≈ 636 SCFM1,080 m³/h | 400/3/50 |
| DRYPOINT RA III 1080 WC | ≈ 636 SCFM1,080 m³/h | 400/3/50 |
| DRYPOINT RA III 1300 AC | ≈ 742 SCFM1,260 m³/h | 400/3/50 |
| DRYPOINT RA III 1300 WC | ≈ 742 SCFM1,260 m³/h | 400/3/50 |
| DRYPOINT RA III 1490 AC | ≈ 883 SCFM1,500 m³/h | 400/3/50 |
| DRYPOINT RA III 1490 WC | ≈ 883 SCFM1,500 m³/h | 400/3/50 |
| DRYPOINT RA III 1900 AC | ≈ 1,118 SCFM1,900 m³/h | 400/3/50 |
| DRYPOINT RA III 1900 WC | ≈ 1,118 SCFM1,900 m³/h | 400/3/50 |
| DRYPOINT RA III 2400 AC | ≈ 1,413 SCFM2,400 m³/h | 400/3/50 |
| DRYPOINT RA III 2400 WC | ≈ 1,413 SCFM2,400 m³/h | 400/3/50 |
| DRYPOINT RA III 3000 AC | ≈ 1,766 SCFM3,000 m³/h | 400/3/50 |
| DRYPOINT RA III 3000 WC | ≈ 1,766 SCFM3,000 m³/h | 400/3/50 |
Comparable lines (8)
- Ingersoll Rand D-IN / D-IT
- Altec AIR RAD / RHT / UA / DX
- Atlas Copco FX 1-21
- Atlas Copco FD / FD VSD / FX
- BOGE DS-2
- Sullair SRN / SRD
- Mikropor MKE
- Purestream (Friulair) FCT
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
DRYPOINT RX / RA
Recorded wording: DRYPOINT RX/RA (US)
- Flow
- 10 to 10,000 SCFM (≈ 17 to 16,990 m³/h)at the manufacturer’s reference conditions
- Dew point
- 2.8 to 10 °C (37 to 50 °F)≤37–45 °F class 4–5 (HT: 45–50 °F class 5–6)
- ISO 8573-1 class
- Classes 4, 5, 6
- Frequency
- n/a
- Voltages
- 115V · 230V · 460V
- CSA · CRN
- yes (UL/CSA) · n/a
- Features
- High inlet temperature · High pressure
Models
| Model | Flow | Type | Dew point | ISO class | Voltage |
|---|---|---|---|---|---|
| DRYPOINT RAc 10DRYPOINT RAc | 10 SCFM≈ 17 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 115 V/1 Ph |
| DRYPOINT RX 10DRYPOINT RX | 10 SCFM≈ 17 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RAc 15DRYPOINT RAc | 15 SCFM≈ 25 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 115 V/1 Ph |
| DRYPOINT RS HP 15DRYPOINT RS HP | 15 SCFM≈ 25 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 115 V/1 Ph |
| DRYPOINT RAc 20DRYPOINT RAc | 20 SCFM≈ 34 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 115 V/1 Ph |
| DRYPOINT RX 20DRYPOINT RX | 20 SCFM≈ 34 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RA HT 20DRYPOINT RA HT | 20 SCFM≈ 34 m³/h | Non-cycling · High inlet temperature | 7.2 to 10 °C (45 to 50 °F) | Class 6 | 115 V/1 Ph |
| DRYPOINT RX 30DRYPOINT RX | 30 SCFM≈ 51 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RA HT 30DRYPOINT RA HT | 30 SCFM≈ 51 m³/h | Non-cycling · High inlet temperature | 7.2 to 10 °C (45 to 50 °F) | Class 6 | 115 V/1 Ph |
| DRYPOINT RS HP 30DRYPOINT RS HP | 30 SCFM≈ 51 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 115 V/1 Ph |
| DRYPOINT RAc 35DRYPOINT RAc | 35 SCFM≈ 59 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 115 V/1 Ph |
| DRYPOINT RA HT 40DRYPOINT RA HT | 40 SCFM≈ 68 m³/h | Non-cycling · High inlet temperature | 7.2 to 10 °C (45 to 50 °F) | Class 6 | 115 V/1 Ph |
| DRYPOINT RS HP 40DRYPOINT RS HP | 40 SCFM≈ 68 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 115 V/1 Ph |
| DRYPOINT RAc 50DRYPOINT RAc | 50 SCFM≈ 85 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 115 V/1 Ph |
| DRYPOINT RX 50DRYPOINT RX | 50 SCFM≈ 85 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RA HT 50DRYPOINT RA HT | 50 SCFM≈ 85 m³/h | Non-cycling · High inlet temperature | 7.2 to 10 °C (45 to 50 °F) | Class 6 | 115 V/1 Ph |
| DRYPOINT RS HP 50DRYPOINT RS HP | 50 SCFM≈ 85 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 115 V/1 Ph |
| DRYPOINT RX 60DRYPOINT RX | 60 SCFM≈ 102 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RX 70DRYPOINT RX | 70 SCFM≈ 119 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RAc 75DRYPOINT RAc | 75 SCFM≈ 127 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 115 V/1 Ph |
| DRYPOINT RA HT 75DRYPOINT RA HT | 75 SCFM≈ 127 m³/h | Non-cycling · High inlet temperature | 7.2 to 10 °C (45 to 50 °F) | Class 6 | 115 V/1 Ph |
| DRYPOINT RS HP 80DRYPOINT RS HP | 80 SCFM≈ 136 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 115 V/1 Ph |
| DRYPOINT RAc 100DRYPOINT RAc | 100 SCFM≈ 170 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 115 V/1 Ph |
| DRYPOINT RX 100DRYPOINT RX | 100 SCFM≈ 170 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RA HT 100DRYPOINT RA HT | 100 SCFM≈ 170 m³/h | Non-cycling · High inlet temperature | 7.2 to 10 °C (45 to 50 °F) | Class 6 | 115 V/1 Ph |
| DRYPOINT RS HP 100DRYPOINT RS HP | 100 SCFM≈ 170 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 115 V/1 Ph |
| DRYPOINT RAc 125DRYPOINT RAc | 125 SCFM≈ 212 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 115 V/1 Ph |
| DRYPOINT RX 125DRYPOINT RX | 125 SCFM≈ 212 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RS HP 140DRYPOINT RS HP | 140 SCFM≈ 238 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 115 V/1 Ph |
| DRYPOINT RAc 150DRYPOINT RAc | 150 SCFM≈ 255 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 115 V/1 Ph |
| DRYPOINT RX 150DRYPOINT RX | 150 SCFM≈ 255 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RA HT 150DRYPOINT RA HT | 150 SCFM≈ 255 m³/h | Non-cycling · High inlet temperature | 7.2 to 10 °C (45 to 50 °F) | Class 6 | 115 V/1 Ph |
| DRYPOINT RAc 175DRYPOINT RAc | 175 SCFM≈ 297 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 230 V/1 Ph |
| DRYPOINT RS HP 180DRYPOINT RS HP | 180 SCFM≈ 306 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 115 V/1 Ph |
| DRYPOINT RX 200DRYPOINT RX | 200 SCFM≈ 340 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RA HT 200DRYPOINT RA HT | 200 SCFM≈ 340 m³/h | Non-cycling · High inlet temperature | 7.2 to 10 °C (45 to 50 °F) | Class 6 | 230 V/1 Ph |
| DRYPOINT RAc 220DRYPOINT RAc | 220 SCFM≈ 374 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 230 V/1 Ph |
| DRYPOINT RX 250DRYPOINT RX | 250 SCFM≈ 425 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RA HT 250DRYPOINT RA HT | 250 SCFM≈ 425 m³/h | Non-cycling · High inlet temperature | 7.2 to 10 °C (45 to 50 °F) | Class 6 | 230 V/1 Ph |
| DRYPOINT RS HP 260DRYPOINT RS HP | 260 SCFM≈ 442 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 230 V/1 Ph |
| DRYPOINT RAc 300DRYPOINT RAc | 300 SCFM≈ 510 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 230 V/1 Ph |
| DRYPOINT RX 300DRYPOINT RX | 300 SCFM≈ 510 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RA HT 300DRYPOINT RA HT | 300 SCFM≈ 510 m³/h | Non-cycling · High inlet temperature | 7.2 to 10 °C (45 to 50 °F) | Class 6 | 230 V/1 Ph |
| DRYPOINT RX 350DRYPOINT RX | 350 SCFM≈ 595 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RA HT 350DRYPOINT RA HT | 350 SCFM≈ 595 m³/h | Non-cycling · High inlet temperature | 7.2 to 10 °C (45 to 50 °F) | Class 6 | 230 V/1 Ph |
| DRYPOINT RS HP 350DRYPOINT RS HP | 350 SCFM≈ 595 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 230 V/1 Ph |
| DRYPOINT RAc 375DRYPOINT RAc | 375 SCFM≈ 637 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 230 V/1 Ph |
| DRYPOINT RX 450DRYPOINT RX | 450 SCFM≈ 765 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RS HP 450DRYPOINT RS HP | 450 SCFM≈ 765 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 230 V/1 Ph |
| DRYPOINT RAc 480DRYPOINT RAc | 480 SCFM≈ 816 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 230 V/1 Ph |
| DRYPOINT RX 550DRYPOINT RX | 550 SCFM≈ 934 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RS HP 550DRYPOINT RS HP | 550 SCFM≈ 934 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 460 V/3 Ph |
| DRYPOINT RX 700DRYPOINT RX | 700 SCFM≈ 1,189 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RS HP 700DRYPOINT RS HP | 700 SCFM≈ 1,189 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 460 V/3 Ph |
| DRYPOINT RX 800DRYPOINT RX | 800 SCFM≈ 1,359 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RS HP 900DRYPOINT RS HP | 900 SCFM≈ 1,529 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 460 V/3 Ph |
| DRYPOINT RX 1000DRYPOINT RX | 1,000 SCFM≈ 1,699 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RX 1300DRYPOINT RX | 1,300 SCFM≈ 2,209 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RS HP 1300DRYPOINT RS HP | 1,300 SCFM≈ 2,209 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 460 V/3 Ph |
| DRYPOINT RS HP 1400DRYPOINT RS HP | 1,400 SCFM≈ 2,379 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 460 V/3 Ph |
| DRYPOINT RX 1500DRYPOINT RX | 1,500 SCFM≈ 2,549 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RX 1700DRYPOINT RX | 1,700 SCFM≈ 2,888 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RS HP 1700DRYPOINT RS HP | 1,700 SCFM≈ 2,888 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 460 V/3 Ph |
| DRYPOINT RAx 2000DRYPOINT RAx | 2,000 SCFM≈ 3,398 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RS HP 2300DRYPOINT RS HP | 2,300 SCFM≈ 3,908 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 460 V/3 Ph |
| DRYPOINT RAx 2500DRYPOINT RAx | 2,500 SCFM≈ 4,248 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RS HP 2900DRYPOINT RS HP | 2,900 SCFM≈ 4,927 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 460 V/3 Ph |
| DRYPOINT RAx 3000DRYPOINT RAx | 3,000 SCFM≈ 5,097 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RS HP 3500DRYPOINT RS HP | 3,500 SCFM≈ 5,947 m³/h | Non-cycling · High pressure | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | 460 V/3 Ph |
| DRYPOINT RAx 4000DRYPOINT RAx | 4,000 SCFM≈ 6,796 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RAx 5000DRYPOINT RAx | 5,000 SCFM≈ 8,495 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RAx 6000DRYPOINT RAx | 6,000 SCFM≈ 10,194 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RAx 7500DRYPOINT RAx | 7,500 SCFM≈ 12,743 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RAx 8000DRYPOINT RAx | 8,000 SCFM≈ 13,592 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
| DRYPOINT RAx 10000DRYPOINT RAx | 10,000 SCFM≈ 16,990 m³/h | Non-cycling | 2.8 to 7.2 °C (37 to 45 °F) | Class 4 to 5 | n/a |
Comparable lines (8)
- Purestream (Friulair) FCT
- Purestream (Friulair) ACT (→ FCT)
- Mikropor MKE
- Mattei MD Ecologic
- Gardner Denver XGNC
- OMI ED Easy Dry / ESD
- Sullair SRN / SRD
- CompAir CD
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
DRYPOINT ACC
- Flow
- 4 to 110 SCFM (≈ 7 to 187 m³/h)at the manufacturer’s reference conditions
- Dew point
- -73.3 to -40 °C (-99.9 to -40 °F)-40 °F (flow at -100 °F also stated)
- ISO 8573-1 class
- Class 1 to 2 (derived)
- Frequency
- 50 Hz · 60 Hz
- Voltages
- 12-24 VDC / 100-240 VAC
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessDew point -73.3 to -40 °C (-99.9 to -40 °F)ISO class Class 1 to 2 (derived)Voltage 12-24 VDC / 100-240 VAC
Comparable lines (8)
- Ingersoll Rand DA…IM (modular)
- Deltech DHDM (modular)
- Hankison PHDM (modular)
- ZEKS ZMA (modular)
- Kaeser DC-HF
- Sullair DMD (modular)
- MTA DryXtreme NA
- Chicago Pneumatic CPADM (modular)
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
DRYPOINT AC HP
- Flow
- 35 to 480 SCFM (≈ 59 to 816 m³/h)at the manufacturer’s reference conditions
- Dew point
- -73.3 to -40 °C (-99.9 to -40 °F)-40 °F std / -100 °F optional
- ISO 8573-1 class
- Class 1 to 2 (derived)
- Frequency
- 50 Hz · 60 Hz
- Voltages
- 85-265 VAC; 24 VDC
- CSA · CRN
- n/a · n/a
- Features
- High pressure
- Sources
- Manufacturer’s page
Models
All models: Type Heatless · High pressureDew point -73.3 to -40 °C (-99.9 to -40 °F)ISO class Class 1 to 2 (derived)Voltage 85-265 VAC; 24 VDC
| Model | Flow |
|---|---|
| AC 60 HP 100 | 35 SCFM≈ 59 m³/h |
| AC 90 HP 100 | 50 SCFM≈ 85 m³/h |
| AC 110 HP 250 | 65 SCFM≈ 110 m³/h |
| AC 145 HP 250 | 85 SCFM≈ 144 m³/h |
| AC 145 HP 350 | 85 SCFM≈ 144 m³/h |
| AC 160 HP 100 | 95 SCFM≈ 161 m³/h |
| AC 190 HP 350 | 110 SCFM≈ 187 m³/h |
| AC 210 HP 250 | 125 SCFM≈ 212 m³/h |
| AC 250 HP 100 | 145 SCFM≈ 246 m³/h |
| AC 265 HP 350 | 155 SCFM≈ 263 m³/h |
| AC 390 HP 100 | 230 SCFM≈ 391 m³/h |
| AC 440 HP 250 | 260 SCFM≈ 442 m³/h |
| AC 540 HP 350 | 315 SCFM≈ 535 m³/h |
| AC 655 HP 250 | 385 SCFM≈ 654 m³/h |
| AC 820 HP 350 | 480 SCFM≈ 816 m³/h |
Comparable lines (8)
- Ultrafilter HeatLess HL
- Pneumatech PH 55-310 HE (US)
- ALUP AD 90-940
- Worthington Creyssensac DB 90-940
- Altec AIR HLD basse PDP
- Atlas Copco CD+ 5-335
- Pneumatic Products (SPX) CDA Heat-Les
- Hertz Kompressoren HHD 16-20 bar
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
DRYPOINT XCe
- Flow
- 80 to 800 SCFM (≈ 136 to 1,359 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °F
- ISO 8573-1 class
- Class 2 (derived)
- Frequency
- 50 Hz · 60 Hz
- Voltages
- 120 VAC
- CSA · CRN
- cULus (controller) · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessDew point -40 °C (-40 °F)ISO class Class 2 (derived)Voltage 120 VAC
| Model | Flow |
|---|---|
| XCe 80 | 80 SCFM≈ 136 m³/h |
| XCe100 | 100 SCFM≈ 170 m³/h |
| XCe 120 | 120 SCFM≈ 204 m³/h |
| XCe 160 | 160 SCFM≈ 272 m³/h |
| XCe 200 | 200 SCFM≈ 340 m³/h |
| XCe 250 | 250 SCFM≈ 425 m³/h |
| XCe 300 | 300 SCFM≈ 510 m³/h |
| XCe 400 | 400 SCFM≈ 680 m³/h |
| XCe 500 | 500 SCFM≈ 850 m³/h |
| XCe 650 | 650 SCFM≈ 1,104 m³/h |
| XCe 800 | 800 SCFM≈ 1,359 m³/h |
Comparable lines (8)
- Sullivan-Palatek SPDP Pro Heatless
- Pneumatech PH 90-690 HE (solid desiccant)
- FINI HDT
- Altec AIR HRL
- Altec AIR HHP high pressure
- Van Air Systems HLSXG (antidéflagrant, gaz naturel)
- Pneumatic Products (SPX) DHA Heat-Les
- Parker PNEUDRI DH MAXI
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
DRYPOINT XCp
- Flow
- 80 to 2,800 SCFM (≈ 136 to 4,757 m³/h)at the manufacturer’s reference conditions
- Dew point
- -73.3 to -40 °C (-99.9 to -40 °F)-40 °F std / -100 °F optional
- ISO 8573-1 class
- Class 1 to 2 (derived)
- Frequency
- 50 Hz · 60 Hz
- Voltages
- 120 VAC
- CSA · CRN
- cULus (controller) · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessDew point -73.3 to -40 °C (-99.9 to -40 °F)ISO class Class 1 to 2 (derived)Voltage 120 VAC
| Model | Flow |
|---|---|
| XCp 80 | 80 SCFM≈ 136 m³/h |
| XCp 100 | 100 SCFM≈ 170 m³/h |
| XCp 120 | 120 SCFM≈ 204 m³/h |
| XCp 160 | 160 SCFM≈ 272 m³/h |
| XCp 200 | 200 SCFM≈ 340 m³/h |
| XCp 250 | 250 SCFM≈ 425 m³/h |
| XCp 300 | 300 SCFM≈ 510 m³/h |
| XCp 400 | 400 SCFM≈ 680 m³/h |
| XCp 500 | 500 SCFM≈ 850 m³/h |
| XCp 650 | 650 SCFM≈ 1,104 m³/h |
| XCp 800 | 800 SCFM≈ 1,359 m³/h |
| XCp 1000 | 1,000 SCFM≈ 1,699 m³/h |
| XCp 1200 | 1,200 SCFM≈ 2,039 m³/h |
| XCp 1500 | 1,500 SCFM≈ 2,549 m³/h |
| XCp 1900 | 1,900 SCFM≈ 3,228 m³/h |
| XCp 2300 | 2,300 SCFM≈ 3,908 m³/h |
| XCp 2800 | 2,800 SCFM≈ 4,757 m³/h |
Comparable lines (8)
- Sullivan-Palatek SPDPR Premium Heatless
- Altec AIR MHR
- Champion CDT
- Gardner Denver DGH
- Hankison HHX
- Hankison HHS
- Hankison HHL
- Kaeser KAD
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
DRYPOINT AC 410-495
- Flow
- 100 to 1,000 m³/h (≈ 59 to 589 SCFM)at the manufacturer’s reference conditions
- Dew point
- -70 to -40 °C (-94 to -40 °F)-40 °C min. (optional -70 °C, version MS)
- ISO 8573-1 class
- Class 1 to 2 (derived)
- Frequency
- 50 Hz · 60 Hz
- Voltages
- 230 V (optional 115 V, 24 VDC)
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessConditions 7 bar, PDP -40 °CDew point -70 to -40 °C (-94 to -40 °F)ISO class Class 1 to 2 (derived)Voltage 230 V (optional 115 V, 24 VDC)
Comparable lines (8)
- Pneumatic Products (SPX) CDA Heat-Les
- Altec AIR HLD basse PDP
- ALUP AD 90-940
- Worthington Creyssensac DB 90-940
- FINI HDT
- Ultrafilter HeatLess HL
- Pneumatech PH 55-310 HE (US)
- Parker PNEUDRI DH MAXI
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
DRYPOINT AC 119-196
- Flow
- 10.2 to 119 m³/h (≈ 6 to 70 SCFM)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °C
- ISO 8573-1 class
- Class 2 (derived)
- Frequency
- 50 Hz · 60 Hz
- Voltages
- 100-240 VAC / 12-24 VDC
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessDew point -40 °C (-40 °F)ISO class Class 2 (derived)Voltage 100-240 VAC / 12-24 VDC
Comparable lines (8)
- Ingersoll Rand DA…IM (modular)
- Deltech DHDM (modular)
- Hankison PHDM (modular)
- ZEKS ZMA (modular)
- Kaeser DC-HF
- MTA DryXtreme NA
- Chicago Pneumatic CPADM (modular)
- Sullair DMD (modular)
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
EVERDRY FRL (North America)
Recorded wording: EVERDRY FRL
- Flow
- 350 to 12,000 SCFM (≈ 595 to 20,388 m³/h)at the manufacturer’s reference conditions
- Dew point
- -70 to -40 °C (-94 to -40 °F)-40 °F (optional -94 °F)
- ISO 8573-1 class
- Class 1 to 2 (derived)
- Frequency
- 60 Hz
- Voltages
- 460/3/60
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Blower purgeDew point -70 to -40 °C (-94 to -40 °F)ISO class Class 1 to 2 (derived)Voltage 460/3/60
| Model | Flow |
|---|---|
| FRL 350 | 350 SCFM≈ 595 m³/h |
| FRL 430 | 430 SCFM≈ 731 m³/h |
| FRL 520 | 520 SCFM≈ 883 m³/h |
| FRL 650 | 650 SCFM≈ 1,104 m³/h |
| FRL 850 | 850 SCFM≈ 1,444 m³/h |
| FRL 1000 | 1,000 SCFM≈ 1,699 m³/h |
| FRL 2500 | 2,500 SCFM≈ 4,248 m³/h |
| FRL 3000 | 3,000 SCFM≈ 5,097 m³/h |
| FRL 3600 | 3,600 SCFM≈ 6,116 m³/h |
| FRL 4200 | 4,200 SCFM≈ 7,136 m³/h |
| FRL 4900 | 4,900 SCFM≈ 8,325 m³/h |
| FRL 5500 | 5,500 SCFM≈ 9,345 m³/h |
| FRL 6500 | 6,500 SCFM≈ 11,044 m³/h |
| FRL 7100 | 7,100 SCFM≈ 12,063 m³/h |
| FRL 8000 | 8,000 SCFM≈ 13,592 m³/h |
| FRL 9000 | 9,000 SCFM≈ 15,291 m³/h |
| FRL 10000 | 10,000 SCFM≈ 16,990 m³/h |
| FRL 12000 | 12,000 SCFM≈ 20,388 m³/h |
Comparable lines (4)
- Nano Purification D5 BP ZP (zero purge)
- Pneumatech PB 760-7400 HE
- Atlas Copco BD+
- Atlas Copco BD+ ZP
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
DRYPOINT XFe
- Flow
- 800 to 6,000 SCFM (≈ 1,359 to 10,194 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °F
- ISO 8573-1 class
- Class 2 (derived)
- Frequency
- 60 Hz
- Voltages
- 460/3/60
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Blower purgeDew point -40 °C (-40 °F)ISO class Class 2 (derived)Voltage 460/3/60
| Model | Flow |
|---|---|
| XFe 800 | 800 SCFM≈ 1,359 m³/h |
| XFe 1000 | 1,000 SCFM≈ 1,699 m³/h |
| XFe 1200 | 1,200 SCFM≈ 2,039 m³/h |
| XFe 1500 | 1,500 SCFM≈ 2,549 m³/h |
| XFe 1800 | 1,800 SCFM≈ 3,058 m³/h |
| XFe 2300 | 2,300 SCFM≈ 3,908 m³/h |
| XFe 2800 | 2,800 SCFM≈ 4,757 m³/h |
| XFe 3300 | 3,300 SCFM≈ 5,607 m³/h |
| XFe 4000 | 4,000 SCFM≈ 6,796 m³/h |
| XFe 5000 | 5,000 SCFM≈ 8,495 m³/h |
| XFe 6000 | 6,000 SCFM≈ 10,194 m³/h |
Comparable lines (8)
- Sullivan-Palatek SPDPHB Pro Heated Blower Purge
- Sullivan-Palatek SPDPRHB Premium Heated Blower Purge
- Nano Purification D5 BP
- Nano Purification D5 BP ZP (zero purge)
- Pneumatech PB 760-7400 HE
- Sullair SAV
- Mattei DDH 850-10800
- Atlas Copco BD 360-1600
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
DRYPOINT XFi
- Flow
- 800 to 6,000 SCFM (≈ 1,359 to 10,194 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °F
- ISO 8573-1 class
- Class 2 (derived)
- Frequency
- 60 Hz
- Voltages
- 460/3/60
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Blower purgeDew point -40 °C (-40 °F)ISO class Class 2 (derived)Voltage 460/3/60
| Model | Flow |
|---|---|
| XFi 800 | 800 SCFM≈ 1,359 m³/h |
| XFi 1000 | 1,000 SCFM≈ 1,699 m³/h |
| XFi 1200 | 1,200 SCFM≈ 2,039 m³/h |
| XFi 1500 | 1,500 SCFM≈ 2,549 m³/h |
| XFi 1800 | 1,800 SCFM≈ 3,058 m³/h |
| XFi 2300 | 2,300 SCFM≈ 3,908 m³/h |
| XFi 2800 | 2,800 SCFM≈ 4,757 m³/h |
| XFi 3300 | 3,300 SCFM≈ 5,607 m³/h |
| XFi 4000 | 4,000 SCFM≈ 6,796 m³/h |
| XFi 5000 | 5,000 SCFM≈ 8,495 m³/h |
| XFi 6000 | 6,000 SCFM≈ 10,194 m³/h |
Comparable lines (8)
- Sullivan-Palatek SPDPHB Pro Heated Blower Purge
- Sullivan-Palatek SPDPRHB Premium Heated Blower Purge
- Nano Purification D5 BP
- Nano Purification D5 BP ZP (zero purge)
- Pneumatech PB 760-7400 HE
- Sullair SAV
- Mattei DDH 850-10800
- Atlas Copco BD 360-1600
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
EVERDRY FRL-V
- Flow
- 580 to 3,400 m³/h (≈ 341 to 2,001 SCFM)at the manufacturer’s reference conditions
- Dew point
- -70 to -40 °C (-94 to -40 °F)-40 °C (optional -70 °C)
- ISO 8573-1 class
- Class 2
- Frequency
- 50 Hz
- Voltages
- 400/3/50
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Blower purgeDew point -70 to -40 °C (-94 to -40 °F)ISO class Class 2Voltage 400/3/50
| Model | Flow |
|---|---|
| FRL-V 0600 | ≈ 341 SCFM580 m³/h |
| FRL-V 0750 | ≈ 424 SCFM720 m³/h |
| FRL-V 0900 | ≈ 518 SCFM880 m³/h |
| FRL-V 1100 | ≈ 647 SCFM1,100 m³/h |
| FRL-V 1400 | ≈ 824 SCFM1,400 m³/h |
| FRL-V 1700 | ≈ 1,001 SCFM1,700 m³/h |
| FRL-V 2000 | ≈ 1,177 SCFM2,000 m³/h |
| FRL-V 2300 | ≈ 1,354 SCFM2,300 m³/h |
| FRL-V 2600 | ≈ 1,530 SCFM2,600 m³/h |
| FRL-V 2900 | ≈ 1,707 SCFM2,900 m³/h |
| FRL-V 3400 | ≈ 2,001 SCFM3,400 m³/h |
Comparable lines (8)
- Altec AIR HBP
- Great Lakes Air GBS
- Quincy QBP
- Champion XCHB
- Gardner Denver GBPD
- Ingersoll Rand HB
- Atlas Copco BD+
- Atlas Copco BD+ ZP
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
EVERDRY FRP
- Flow
- 580 to 20,000 m³/h (≈ 341 to 11,772 SCFM)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °C
- ISO 8573-1 class
- Class 2
- Frequency
- 50 Hz
- Voltages
- 400/3/50
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Blower purgeDew point -40 °C (-40 °F)ISO class Class 2Voltage 400/3/50
| Model | Flow |
|---|---|
| FRP 0600 | ≈ 341 SCFM580 m³/h |
| FRP 0750 | ≈ 424 SCFM720 m³/h |
| FRP 0900 | ≈ 518 SCFM880 m³/h |
| FRP 1100 | ≈ 647 SCFM1,100 m³/h |
| FRP 1400 | ≈ 824 SCFM1,400 m³/h |
| FRP 1700 | ≈ 1,001 SCFM1,700 m³/h |
| FRP 2000 | ≈ 1,177 SCFM2,000 m³/h |
| FRP 2300 | ≈ 1,354 SCFM2,300 m³/h |
| FRP 2600 | ≈ 1,530 SCFM2,600 m³/h |
| FRP 2900 | ≈ 1,707 SCFM2,900 m³/h |
| FRP 3400 | ≈ 2,001 SCFM3,400 m³/h |
| FRP 4200 | ≈ 2,472 SCFM4,200 m³/h |
| FRP 5000 | ≈ 2,943 SCFM5,000 m³/h |
| FRP 6000 | ≈ 3,531 SCFM6,000 m³/h |
| FRP 7000 | ≈ 4,120 SCFM7,000 m³/h |
| FRP 8200 | ≈ 4,826 SCFM8,200 m³/h |
| FRP 9400 | ≈ 5,503 SCFM9,350 m³/h |
| FRP 10600 | ≈ 6,239 SCFM10,600 m³/h |
| FRP 12000 | ≈ 7,063 SCFM12,000 m³/h |
| FRP 13500 | ≈ 7,946 SCFM13,500 m³/h |
| FRP 15000 | ≈ 8,829 SCFM15,000 m³/h |
| FRP 17000 | ≈ 10,006 SCFM17,000 m³/h |
| FRP 20000 | ≈ 11,772 SCFM20,000 m³/h |
Comparable lines (8)
- Sullair SAV
- Nano Purification D5 BP
- Nano Purification D5 BP ZP (zero purge)
- Sullivan-Palatek SPDPHB Pro Heated Blower Purge
- Sullivan-Palatek SPDPRHB Premium Heated Blower Purge
- Mattei DDH 850-10800
- Pneumatech PB 760-7400 HE
- Atlas Copco BD 360-1600
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
EVERDRY FRL (Europe)
Recorded wording: EVERDRY FRL
- Flow
- 4,200 to 20,000 m³/h (≈ 2,472 to 11,772 SCFM)at the manufacturer’s reference conditions
- Dew point
- -70 to -40 °C (-94 to -40 °F)-40 °C (optional -70 °C)
- ISO 8573-1 class
- Class 2
- Frequency
- 50 Hz
- Voltages
- 400/3/50
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Blower purgeDew point -70 to -40 °C (-94 to -40 °F)ISO class Class 2Voltage 400/3/50
| Model | Flow |
|---|---|
| FRL 4200 | ≈ 2,472 SCFM4,200 m³/h |
| FRL 5000 | ≈ 2,943 SCFM5,000 m³/h |
| FRL 6000 | ≈ 3,531 SCFM6,000 m³/h |
| FRL 7000 | ≈ 4,120 SCFM7,000 m³/h |
| FRL 8200 | ≈ 4,826 SCFM8,200 m³/h |
| FRL 9400 | ≈ 5,503 SCFM9,350 m³/h |
| FRL 10600 | ≈ 6,239 SCFM10,600 m³/h |
| FRL 12000 | ≈ 7,063 SCFM12,000 m³/h |
| FRL 13500 | ≈ 7,946 SCFM13,500 m³/h |
| FRL 15000 | ≈ 8,829 SCFM15,000 m³/h |
| FRL 17000 | ≈ 10,006 SCFM17,000 m³/h |
| FRL 20000 | ≈ 11,772 SCFM20,000 m³/h |
Comparable lines (8)
- Pneumatech PB 760-7400 HE
- Sullivan-Palatek SPDPHB Pro Heated Blower Purge
- Sullivan-Palatek SPDPRHB Premium Heated Blower Purge
- Nano Purification D5 BP
- Nano Purification D5 BP ZP (zero purge)
- Sullair SAV
- Mattei DDH 850-10800
- Atlas Copco BD 360-1600
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
DRYPOINT ACH
- Flow
- 70 to 4,050 SCFM (≈ 119 to 6,881 m³/h)at the manufacturer’s reference conditions
- Dew point
- -62.2 to -40 °C (-80 to -40 °F)-40 °F std / -80 °F optional
- ISO 8573-1 class
- Class 2 (derived)
- Frequency
- 60 Hz
- Voltages
- 460/3/60
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Heated purgeDew point -62.2 to -40 °C (-80 to -40 °F)ISO class Class 2 (derived)Voltage 460/3/60
| Model | Flow |
|---|---|
| ACH 70 | 70 SCFM≈ 119 m³/h |
| ACH 130 | 130 SCFM≈ 221 m³/h |
| ACH 180 | 180 SCFM≈ 306 m³/h |
| ACH 260 | 260 SCFM≈ 442 m³/h |
| ACH 355 | 355 SCFM≈ 603 m³/h |
| ACH 460 | 460 SCFM≈ 782 m³/h |
| ACH 575 | 575 SCFM≈ 977 m³/h |
| ACH 720 | 720 SCFM≈ 1,223 m³/h |
| ACH 1010 | 1,010 SCFM≈ 1,716 m³/h |
| ACH 1300 | 1,300 SCFM≈ 2,209 m³/h |
| ACH 1725 | 1,725 SCFM≈ 2,931 m³/h |
| ACH 2350 | 2,350 SCFM≈ 3,993 m³/h |
| ACH 3250 | 3,250 SCFM≈ 5,522 m³/h |
| ACH 4050 | 4,050 SCFM≈ 6,881 m³/h |
Comparable lines (8)
- Sullivan-Palatek SPDH Pro Heated Purge
- Sullivan-Palatek SPDHR Premium Heated Purge
- MTA DryXtreme NST
- Champion XCHP
- Nano Purification D5 EH (US)
- Mattei MEH
- Altec AIR HRE
- Deltech RP
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
EVERDRY HOC-P
- Flow
- 500 to 3,600 SCFM (≈ 850 to 6,116 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °F
- ISO 8573-1 class
- Class 2
- Frequency
- 60 Hz
- Voltages
- 460/3/60
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Heat of compression (HOC)Dew point -40 °C (-40 °F)ISO class Class 2Voltage 460/3/60
Comparable lines (3)
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
DRYPOINT HL
Recorded wording: DRYPOINT HL (série)
- Flow
- n/aat the manufacturer’s reference conditions
- Dew point
- n/a
- ISO 8573-1 class
- n/a
- Frequency
- n/a
- Voltages
- n/a
- CSA · CRN
- n/a · n/a
- Sources
Models
Models (flow, dew point and conditions of each model number) will be added from the brochures.
Comparable lines (0)
No comparable line in the current data.
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
Equivalent equipment at Onyx M3
Purestream (Friulair) refrigerated dryers, distributed by Onyx M3 Inc.