Comparison · Air dryers

BEKO Technologies air dryers

17 refrigerated, desiccant lines (non-cycling, heatless, blower purge, heated purge, heat of compression (hoc)), from the manufacturer’s brochures.

Under construction. This comparison tool is still being built: do not base a purchasing decision on this data. Always confirm with your local distributors.

DRYPOINT RA III

NON-CYC ISO 4 ≈ Worldwide 60 Hz 50 Hz

Recorded wording: DRYPOINT RA III (intl)

Flow
10 to 1,700 SCFM (20 to 3,000 m³/h)at the manufacturer’s reference conditions
Dew point
3 °C (37.4 °F)PDP +3 °C (base volume)
ISO 8573-1 class
Class 4 (derived)
Frequency
50 Hz · 60 Hz
Voltages
n/a
CSA · CRN
n/a · n/a

Models

All models: Type Non-cyclingDew point 3 °C (37.4 °F)ISO class Class 4 (derived)

Model Flow Voltage
DRYPOINT RA III 20 AC ≈ 12 SCFM21 m³/h 230/1/50-60
DRYPOINT RA III 35 AC ≈ 19 SCFM33 m³/h 230/1/50-60
DRYPOINT RA III 50 AC ≈ 30 SCFM51 m³/h 230/1/50-60
DRYPOINT RA III 70 AC ≈ 42 SCFM72 m³/h 230/1/50-60
DRYPOINT RA III 110 AC ≈ 64 SCFM108 m³/h 230/1/50-60
DRYPOINT RA III 135 AC ≈ 81 SCFM138 m³/h 230/1/50-60
DRYPOINT RA III 190 AC ≈ 109 SCFM186 m³/h 230/1/50-60
DRYPOINT RA III 240 AC ≈ 141 SCFM240 m³/h 230/1/50-60
DRYPOINT RA III 330 AC ≈ 194 SCFM330 m³/h 230/1/50-60
DRYPOINT RA III 370 AC ≈ 219 SCFM372 m³/h 230/1/50
DRYPOINT RA III 490 AC ≈ 286 SCFM486 m³/h 230/1/50
DRYPOINT RA III 630 AC ≈ 371 SCFM630 m³/h 230/1/50
DRYPOINT RA III 750 AC ≈ 441 SCFM750 m³/h 230/1/50
DRYPOINT RA III 750 WC ≈ 441 SCFM750 m³/h 230/1/50
DRYPOINT RA III 870 AC ≈ 512 SCFM870 m³/h 230/1/50
DRYPOINT RA III 870 WC ≈ 512 SCFM870 m³/h 230/1/50
DRYPOINT RA III 960 AC ≈ 565 SCFM960 m³/h 230/1/50
DRYPOINT RA III 960 WC ≈ 565 SCFM960 m³/h 230/1/50
DRYPOINT RA III 1080 AC ≈ 636 SCFM1,080 m³/h 400/3/50
DRYPOINT RA III 1080 WC ≈ 636 SCFM1,080 m³/h 400/3/50
DRYPOINT RA III 1300 AC ≈ 742 SCFM1,260 m³/h 400/3/50
DRYPOINT RA III 1300 WC ≈ 742 SCFM1,260 m³/h 400/3/50
DRYPOINT RA III 1490 AC ≈ 883 SCFM1,500 m³/h 400/3/50
DRYPOINT RA III 1490 WC ≈ 883 SCFM1,500 m³/h 400/3/50
DRYPOINT RA III 1900 AC ≈ 1,118 SCFM1,900 m³/h 400/3/50
DRYPOINT RA III 1900 WC ≈ 1,118 SCFM1,900 m³/h 400/3/50
DRYPOINT RA III 2400 AC ≈ 1,413 SCFM2,400 m³/h 400/3/50
DRYPOINT RA III 2400 WC ≈ 1,413 SCFM2,400 m³/h 400/3/50
DRYPOINT RA III 3000 AC ≈ 1,766 SCFM3,000 m³/h 400/3/50
DRYPOINT RA III 3000 WC ≈ 1,766 SCFM3,000 m³/h 400/3/50
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

DRYPOINT RX / RA

NON-CYC ISO 4–6 North America CSA

Recorded wording: DRYPOINT RX/RA (US)

Flow
10 to 10,000 SCFM (≈ 17 to 16,990 m³/h)at the manufacturer’s reference conditions
Dew point
2.8 to 10 °C (37 to 50 °F)≤37–45 °F class 4–5 (HT: 45–50 °F class 5–6)
ISO 8573-1 class
Classes 4, 5, 6
Frequency
n/a
Voltages
115V · 230V · 460V
CSA · CRN
yes (UL/CSA) · n/a
Features
High inlet temperature · High pressure

Models

Model Flow TypeDew pointISO classVoltage
DRYPOINT RAc 10DRYPOINT RAc 10 SCFM≈ 17 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5115 V/1 Ph
DRYPOINT RX 10DRYPOINT RX 10 SCFM≈ 17 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RAc 15DRYPOINT RAc 15 SCFM≈ 25 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5115 V/1 Ph
DRYPOINT RS HP 15DRYPOINT RS HP 15 SCFM≈ 25 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5115 V/1 Ph
DRYPOINT RAc 20DRYPOINT RAc 20 SCFM≈ 34 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5115 V/1 Ph
DRYPOINT RX 20DRYPOINT RX 20 SCFM≈ 34 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RA HT 20DRYPOINT RA HT 20 SCFM≈ 34 m³/h Non-cycling · High inlet temperature7.2 to 10 °C (45 to 50 °F)Class 6115 V/1 Ph
DRYPOINT RX 30DRYPOINT RX 30 SCFM≈ 51 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RA HT 30DRYPOINT RA HT 30 SCFM≈ 51 m³/h Non-cycling · High inlet temperature7.2 to 10 °C (45 to 50 °F)Class 6115 V/1 Ph
DRYPOINT RS HP 30DRYPOINT RS HP 30 SCFM≈ 51 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5115 V/1 Ph
DRYPOINT RAc 35DRYPOINT RAc 35 SCFM≈ 59 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5115 V/1 Ph
DRYPOINT RA HT 40DRYPOINT RA HT 40 SCFM≈ 68 m³/h Non-cycling · High inlet temperature7.2 to 10 °C (45 to 50 °F)Class 6115 V/1 Ph
DRYPOINT RS HP 40DRYPOINT RS HP 40 SCFM≈ 68 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5115 V/1 Ph
DRYPOINT RAc 50DRYPOINT RAc 50 SCFM≈ 85 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5115 V/1 Ph
DRYPOINT RX 50DRYPOINT RX 50 SCFM≈ 85 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RA HT 50DRYPOINT RA HT 50 SCFM≈ 85 m³/h Non-cycling · High inlet temperature7.2 to 10 °C (45 to 50 °F)Class 6115 V/1 Ph
DRYPOINT RS HP 50DRYPOINT RS HP 50 SCFM≈ 85 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5115 V/1 Ph
DRYPOINT RX 60DRYPOINT RX 60 SCFM≈ 102 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RX 70DRYPOINT RX 70 SCFM≈ 119 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RAc 75DRYPOINT RAc 75 SCFM≈ 127 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5115 V/1 Ph
DRYPOINT RA HT 75DRYPOINT RA HT 75 SCFM≈ 127 m³/h Non-cycling · High inlet temperature7.2 to 10 °C (45 to 50 °F)Class 6115 V/1 Ph
DRYPOINT RS HP 80DRYPOINT RS HP 80 SCFM≈ 136 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5115 V/1 Ph
DRYPOINT RAc 100DRYPOINT RAc 100 SCFM≈ 170 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5115 V/1 Ph
DRYPOINT RX 100DRYPOINT RX 100 SCFM≈ 170 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RA HT 100DRYPOINT RA HT 100 SCFM≈ 170 m³/h Non-cycling · High inlet temperature7.2 to 10 °C (45 to 50 °F)Class 6115 V/1 Ph
DRYPOINT RS HP 100DRYPOINT RS HP 100 SCFM≈ 170 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5115 V/1 Ph
DRYPOINT RAc 125DRYPOINT RAc 125 SCFM≈ 212 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5115 V/1 Ph
DRYPOINT RX 125DRYPOINT RX 125 SCFM≈ 212 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RS HP 140DRYPOINT RS HP 140 SCFM≈ 238 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5115 V/1 Ph
DRYPOINT RAc 150DRYPOINT RAc 150 SCFM≈ 255 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5115 V/1 Ph
DRYPOINT RX 150DRYPOINT RX 150 SCFM≈ 255 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RA HT 150DRYPOINT RA HT 150 SCFM≈ 255 m³/h Non-cycling · High inlet temperature7.2 to 10 °C (45 to 50 °F)Class 6115 V/1 Ph
DRYPOINT RAc 175DRYPOINT RAc 175 SCFM≈ 297 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5230 V/1 Ph
DRYPOINT RS HP 180DRYPOINT RS HP 180 SCFM≈ 306 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5115 V/1 Ph
DRYPOINT RX 200DRYPOINT RX 200 SCFM≈ 340 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RA HT 200DRYPOINT RA HT 200 SCFM≈ 340 m³/h Non-cycling · High inlet temperature7.2 to 10 °C (45 to 50 °F)Class 6230 V/1 Ph
DRYPOINT RAc 220DRYPOINT RAc 220 SCFM≈ 374 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5230 V/1 Ph
DRYPOINT RX 250DRYPOINT RX 250 SCFM≈ 425 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RA HT 250DRYPOINT RA HT 250 SCFM≈ 425 m³/h Non-cycling · High inlet temperature7.2 to 10 °C (45 to 50 °F)Class 6230 V/1 Ph
DRYPOINT RS HP 260DRYPOINT RS HP 260 SCFM≈ 442 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5230 V/1 Ph
DRYPOINT RAc 300DRYPOINT RAc 300 SCFM≈ 510 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5230 V/1 Ph
DRYPOINT RX 300DRYPOINT RX 300 SCFM≈ 510 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RA HT 300DRYPOINT RA HT 300 SCFM≈ 510 m³/h Non-cycling · High inlet temperature7.2 to 10 °C (45 to 50 °F)Class 6230 V/1 Ph
DRYPOINT RX 350DRYPOINT RX 350 SCFM≈ 595 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RA HT 350DRYPOINT RA HT 350 SCFM≈ 595 m³/h Non-cycling · High inlet temperature7.2 to 10 °C (45 to 50 °F)Class 6230 V/1 Ph
DRYPOINT RS HP 350DRYPOINT RS HP 350 SCFM≈ 595 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5230 V/1 Ph
DRYPOINT RAc 375DRYPOINT RAc 375 SCFM≈ 637 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5230 V/1 Ph
DRYPOINT RX 450DRYPOINT RX 450 SCFM≈ 765 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RS HP 450DRYPOINT RS HP 450 SCFM≈ 765 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5230 V/1 Ph
DRYPOINT RAc 480DRYPOINT RAc 480 SCFM≈ 816 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5230 V/1 Ph
DRYPOINT RX 550DRYPOINT RX 550 SCFM≈ 934 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RS HP 550DRYPOINT RS HP 550 SCFM≈ 934 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5460 V/3 Ph
DRYPOINT RX 700DRYPOINT RX 700 SCFM≈ 1,189 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RS HP 700DRYPOINT RS HP 700 SCFM≈ 1,189 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5460 V/3 Ph
DRYPOINT RX 800DRYPOINT RX 800 SCFM≈ 1,359 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RS HP 900DRYPOINT RS HP 900 SCFM≈ 1,529 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5460 V/3 Ph
DRYPOINT RX 1000DRYPOINT RX 1,000 SCFM≈ 1,699 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RX 1300DRYPOINT RX 1,300 SCFM≈ 2,209 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RS HP 1300DRYPOINT RS HP 1,300 SCFM≈ 2,209 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5460 V/3 Ph
DRYPOINT RS HP 1400DRYPOINT RS HP 1,400 SCFM≈ 2,379 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5460 V/3 Ph
DRYPOINT RX 1500DRYPOINT RX 1,500 SCFM≈ 2,549 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RX 1700DRYPOINT RX 1,700 SCFM≈ 2,888 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RS HP 1700DRYPOINT RS HP 1,700 SCFM≈ 2,888 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5460 V/3 Ph
DRYPOINT RAx 2000DRYPOINT RAx 2,000 SCFM≈ 3,398 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RS HP 2300DRYPOINT RS HP 2,300 SCFM≈ 3,908 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5460 V/3 Ph
DRYPOINT RAx 2500DRYPOINT RAx 2,500 SCFM≈ 4,248 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RS HP 2900DRYPOINT RS HP 2,900 SCFM≈ 4,927 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5460 V/3 Ph
DRYPOINT RAx 3000DRYPOINT RAx 3,000 SCFM≈ 5,097 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RS HP 3500DRYPOINT RS HP 3,500 SCFM≈ 5,947 m³/h Non-cycling · High pressure2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5460 V/3 Ph
DRYPOINT RAx 4000DRYPOINT RAx 4,000 SCFM≈ 6,796 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RAx 5000DRYPOINT RAx 5,000 SCFM≈ 8,495 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RAx 6000DRYPOINT RAx 6,000 SCFM≈ 10,194 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RAx 7500DRYPOINT RAx 7,500 SCFM≈ 12,743 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RAx 8000DRYPOINT RAx 8,000 SCFM≈ 13,592 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
DRYPOINT RAx 10000DRYPOINT RAx 10,000 SCFM≈ 16,990 m³/h Non-cycling2.8 to 7.2 °C (37 to 45 °F)Class 4 to 5n/a
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

DRYPOINT ACC

HL ISO 1–2 ≈ North America 60 Hz 50 Hz
Flow
4 to 110 SCFM (≈ 7 to 187 m³/h)at the manufacturer’s reference conditions
Dew point
-73.3 to -40 °C (-99.9 to -40 °F)-40 °F (flow at -100 °F also stated)
ISO 8573-1 class
Class 1 to 2 (derived)
Frequency
50 Hz · 60 Hz
Voltages
12-24 VDC / 100-240 VAC
CSA · CRN
n/a · n/a

Models

All models: Type HeatlessDew point -73.3 to -40 °C (-99.9 to -40 °F)ISO class Class 1 to 2 (derived)Voltage 12-24 VDC / 100-240 VAC

Model Flow
ACC 4 4 SCFM≈ 7 m³/h
ACC 6 6 SCFM≈ 10 m³/h
ACC 8 8 SCFM≈ 14 m³/h
ACC 10 10 SCFM≈ 17 m³/h
ACC 15 15 SCFM≈ 25 m³/h
ACC 25 25 SCFM≈ 42 m³/h
ACC 35 35 SCFM≈ 59 m³/h
ACC 46 45 SCFM≈ 76 m³/h
ACC 56 55 SCFM≈ 93 m³/h
ACC 75 75 SCFM≈ 127 m³/h
ACC 90 90 SCFM≈ 153 m³/h
ACC 110 110 SCFM≈ 187 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

DRYPOINT AC HP

HL ISO 1–2 ≈ North America 60 Hz 50 Hz
Flow
35 to 480 SCFM (≈ 59 to 816 m³/h)at the manufacturer’s reference conditions
Dew point
-73.3 to -40 °C (-99.9 to -40 °F)-40 °F std / -100 °F optional
ISO 8573-1 class
Class 1 to 2 (derived)
Frequency
50 Hz · 60 Hz
Voltages
85-265 VAC; 24 VDC
CSA · CRN
n/a · n/a
Features
High pressure

Models

All models: Type Heatless · High pressureDew point -73.3 to -40 °C (-99.9 to -40 °F)ISO class Class 1 to 2 (derived)Voltage 85-265 VAC; 24 VDC

Model Flow
AC 60 HP 100 35 SCFM≈ 59 m³/h
AC 90 HP 100 50 SCFM≈ 85 m³/h
AC 110 HP 250 65 SCFM≈ 110 m³/h
AC 145 HP 250 85 SCFM≈ 144 m³/h
AC 145 HP 350 85 SCFM≈ 144 m³/h
AC 160 HP 100 95 SCFM≈ 161 m³/h
AC 190 HP 350 110 SCFM≈ 187 m³/h
AC 210 HP 250 125 SCFM≈ 212 m³/h
AC 250 HP 100 145 SCFM≈ 246 m³/h
AC 265 HP 350 155 SCFM≈ 263 m³/h
AC 390 HP 100 230 SCFM≈ 391 m³/h
AC 440 HP 250 260 SCFM≈ 442 m³/h
AC 540 HP 350 315 SCFM≈ 535 m³/h
AC 655 HP 250 385 SCFM≈ 654 m³/h
AC 820 HP 350 480 SCFM≈ 816 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

DRYPOINT XCe

HL ISO 2 ≈ North America 60 Hz 50 Hz cUL
Flow
80 to 800 SCFM (≈ 136 to 1,359 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °F
ISO 8573-1 class
Class 2 (derived)
Frequency
50 Hz · 60 Hz
Voltages
120 VAC
CSA · CRN
cULus (controller) · n/a

DRYPOINT XCp

HL ISO 1–2 ≈ North America 60 Hz 50 Hz cUL
Flow
80 to 2,800 SCFM (≈ 136 to 4,757 m³/h)at the manufacturer’s reference conditions
Dew point
-73.3 to -40 °C (-99.9 to -40 °F)-40 °F std / -100 °F optional
ISO 8573-1 class
Class 1 to 2 (derived)
Frequency
50 Hz · 60 Hz
Voltages
120 VAC
CSA · CRN
cULus (controller) · n/a

Models

All models: Type HeatlessDew point -73.3 to -40 °C (-99.9 to -40 °F)ISO class Class 1 to 2 (derived)Voltage 120 VAC

Model Flow
XCp 80 80 SCFM≈ 136 m³/h
XCp 100 100 SCFM≈ 170 m³/h
XCp 120 120 SCFM≈ 204 m³/h
XCp 160 160 SCFM≈ 272 m³/h
XCp 200 200 SCFM≈ 340 m³/h
XCp 250 250 SCFM≈ 425 m³/h
XCp 300 300 SCFM≈ 510 m³/h
XCp 400 400 SCFM≈ 680 m³/h
XCp 500 500 SCFM≈ 850 m³/h
XCp 650 650 SCFM≈ 1,104 m³/h
XCp 800 800 SCFM≈ 1,359 m³/h
XCp 1000 1,000 SCFM≈ 1,699 m³/h
XCp 1200 1,200 SCFM≈ 2,039 m³/h
XCp 1500 1,500 SCFM≈ 2,549 m³/h
XCp 1900 1,900 SCFM≈ 3,228 m³/h
XCp 2300 2,300 SCFM≈ 3,908 m³/h
XCp 2800 2,800 SCFM≈ 4,757 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

DRYPOINT AC 410-495

HL ISO 1–2 ≈ Europe / international 60 Hz 50 Hz
Flow
100 to 1,000 m³/h (≈ 59 to 589 SCFM)at the manufacturer’s reference conditions
Dew point
-70 to -40 °C (-94 to -40 °F)-40 °C min. (optional -70 °C, version MS)
ISO 8573-1 class
Class 1 to 2 (derived)
Frequency
50 Hz · 60 Hz
Voltages
230 V (optional 115 V, 24 VDC)
CSA · CRN
n/a · n/a

Models

All models: Type HeatlessConditions 7 bar, PDP -40 °CDew point -70 to -40 °C (-94 to -40 °F)ISO class Class 1 to 2 (derived)Voltage 230 V (optional 115 V, 24 VDC)

Model Flow
AC 410 ≈ 59 SCFM100 m³/h
AC 415 ≈ 88 SCFM150 m³/h
AC 418 ≈ 103 SCFM175 m³/h
AC 423 ≈ 132 SCFM225 m³/h
AC 430 ≈ 177 SCFM300 m³/h
AC 438 ≈ 221 SCFM375 m³/h
AC 455 ≈ 324 SCFM550 m³/h
AC 465 ≈ 383 SCFM650 m³/h
AC 485 ≈ 500 SCFM850 m³/h
AC 495 ≈ 589 SCFM1,000 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

DRYPOINT AC 119-196

HL ISO 2 ≈ Europe / international 60 Hz 50 Hz
Flow
10.2 to 119 m³/h (≈ 6 to 70 SCFM)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °C
ISO 8573-1 class
Class 2 (derived)
Frequency
50 Hz · 60 Hz
Voltages
100-240 VAC / 12-24 VDC
CSA · CRN
n/a · n/a

EVERDRY FRL (North America)

BP ISO 1–2 ≈ North America 60 Hz

Recorded wording: EVERDRY FRL

Flow
350 to 12,000 SCFM (≈ 595 to 20,388 m³/h)at the manufacturer’s reference conditions
Dew point
-70 to -40 °C (-94 to -40 °F)-40 °F (optional -94 °F)
ISO 8573-1 class
Class 1 to 2 (derived)
Frequency
60 Hz
Voltages
460/3/60
CSA · CRN
n/a · n/a

Models

All models: Type Blower purgeDew point -70 to -40 °C (-94 to -40 °F)ISO class Class 1 to 2 (derived)Voltage 460/3/60

Model Flow
FRL 350 350 SCFM≈ 595 m³/h
FRL 430 430 SCFM≈ 731 m³/h
FRL 520 520 SCFM≈ 883 m³/h
FRL 650 650 SCFM≈ 1,104 m³/h
FRL 850 850 SCFM≈ 1,444 m³/h
FRL 1000 1,000 SCFM≈ 1,699 m³/h
FRL 2500 2,500 SCFM≈ 4,248 m³/h
FRL 3000 3,000 SCFM≈ 5,097 m³/h
FRL 3600 3,600 SCFM≈ 6,116 m³/h
FRL 4200 4,200 SCFM≈ 7,136 m³/h
FRL 4900 4,900 SCFM≈ 8,325 m³/h
FRL 5500 5,500 SCFM≈ 9,345 m³/h
FRL 6500 6,500 SCFM≈ 11,044 m³/h
FRL 7100 7,100 SCFM≈ 12,063 m³/h
FRL 8000 8,000 SCFM≈ 13,592 m³/h
FRL 9000 9,000 SCFM≈ 15,291 m³/h
FRL 10000 10,000 SCFM≈ 16,990 m³/h
FRL 12000 12,000 SCFM≈ 20,388 m³/h
Comparable lines (4)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

DRYPOINT XFe

BP ISO 2 ≈ North America 60 Hz
Flow
800 to 6,000 SCFM (≈ 1,359 to 10,194 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °F
ISO 8573-1 class
Class 2 (derived)
Frequency
60 Hz
Voltages
460/3/60
CSA · CRN
n/a · n/a

DRYPOINT XFi

BP ISO 2 ≈ North America 60 Hz
Flow
800 to 6,000 SCFM (≈ 1,359 to 10,194 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °F
ISO 8573-1 class
Class 2 (derived)
Frequency
60 Hz
Voltages
460/3/60
CSA · CRN
n/a · n/a

EVERDRY FRL-V

BP ISO 2 Europe / international 50 Hz
Flow
580 to 3,400 m³/h (≈ 341 to 2,001 SCFM)at the manufacturer’s reference conditions
Dew point
-70 to -40 °C (-94 to -40 °F)-40 °C (optional -70 °C)
ISO 8573-1 class
Class 2
Frequency
50 Hz
Voltages
400/3/50
CSA · CRN
n/a · n/a

Models

All models: Type Blower purgeDew point -70 to -40 °C (-94 to -40 °F)ISO class Class 2Voltage 400/3/50

Model Flow
FRL-V 0600 ≈ 341 SCFM580 m³/h
FRL-V 0750 ≈ 424 SCFM720 m³/h
FRL-V 0900 ≈ 518 SCFM880 m³/h
FRL-V 1100 ≈ 647 SCFM1,100 m³/h
FRL-V 1400 ≈ 824 SCFM1,400 m³/h
FRL-V 1700 ≈ 1,001 SCFM1,700 m³/h
FRL-V 2000 ≈ 1,177 SCFM2,000 m³/h
FRL-V 2300 ≈ 1,354 SCFM2,300 m³/h
FRL-V 2600 ≈ 1,530 SCFM2,600 m³/h
FRL-V 2900 ≈ 1,707 SCFM2,900 m³/h
FRL-V 3400 ≈ 2,001 SCFM3,400 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

EVERDRY FRP

BP ISO 2 Europe / international 50 Hz
Flow
580 to 20,000 m³/h (≈ 341 to 11,772 SCFM)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °C
ISO 8573-1 class
Class 2
Frequency
50 Hz
Voltages
400/3/50
CSA · CRN
n/a · n/a

Models

All models: Type Blower purgeDew point -40 °C (-40 °F)ISO class Class 2Voltage 400/3/50

Model Flow
FRP 0600 ≈ 341 SCFM580 m³/h
FRP 0750 ≈ 424 SCFM720 m³/h
FRP 0900 ≈ 518 SCFM880 m³/h
FRP 1100 ≈ 647 SCFM1,100 m³/h
FRP 1400 ≈ 824 SCFM1,400 m³/h
FRP 1700 ≈ 1,001 SCFM1,700 m³/h
FRP 2000 ≈ 1,177 SCFM2,000 m³/h
FRP 2300 ≈ 1,354 SCFM2,300 m³/h
FRP 2600 ≈ 1,530 SCFM2,600 m³/h
FRP 2900 ≈ 1,707 SCFM2,900 m³/h
FRP 3400 ≈ 2,001 SCFM3,400 m³/h
FRP 4200 ≈ 2,472 SCFM4,200 m³/h
FRP 5000 ≈ 2,943 SCFM5,000 m³/h
FRP 6000 ≈ 3,531 SCFM6,000 m³/h
FRP 7000 ≈ 4,120 SCFM7,000 m³/h
FRP 8200 ≈ 4,826 SCFM8,200 m³/h
FRP 9400 ≈ 5,503 SCFM9,350 m³/h
FRP 10600 ≈ 6,239 SCFM10,600 m³/h
FRP 12000 ≈ 7,063 SCFM12,000 m³/h
FRP 13500 ≈ 7,946 SCFM13,500 m³/h
FRP 15000 ≈ 8,829 SCFM15,000 m³/h
FRP 17000 ≈ 10,006 SCFM17,000 m³/h
FRP 20000 ≈ 11,772 SCFM20,000 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

EVERDRY FRL (Europe)

BP ISO 2 Europe / international 50 Hz

Recorded wording: EVERDRY FRL

Flow
4,200 to 20,000 m³/h (≈ 2,472 to 11,772 SCFM)at the manufacturer’s reference conditions
Dew point
-70 to -40 °C (-94 to -40 °F)-40 °C (optional -70 °C)
ISO 8573-1 class
Class 2
Frequency
50 Hz
Voltages
400/3/50
CSA · CRN
n/a · n/a

DRYPOINT ACH

EH ISO 2 ≈ North America 60 Hz
Flow
70 to 4,050 SCFM (≈ 119 to 6,881 m³/h)at the manufacturer’s reference conditions
Dew point
-62.2 to -40 °C (-80 to -40 °F)-40 °F std / -80 °F optional
ISO 8573-1 class
Class 2 (derived)
Frequency
60 Hz
Voltages
460/3/60
CSA · CRN
n/a · n/a

Models

All models: Type Heated purgeDew point -62.2 to -40 °C (-80 to -40 °F)ISO class Class 2 (derived)Voltage 460/3/60

Model Flow
ACH 70 70 SCFM≈ 119 m³/h
ACH 130 130 SCFM≈ 221 m³/h
ACH 180 180 SCFM≈ 306 m³/h
ACH 260 260 SCFM≈ 442 m³/h
ACH 355 355 SCFM≈ 603 m³/h
ACH 460 460 SCFM≈ 782 m³/h
ACH 575 575 SCFM≈ 977 m³/h
ACH 720 720 SCFM≈ 1,223 m³/h
ACH 1010 1,010 SCFM≈ 1,716 m³/h
ACH 1300 1,300 SCFM≈ 2,209 m³/h
ACH 1725 1,725 SCFM≈ 2,931 m³/h
ACH 2350 2,350 SCFM≈ 3,993 m³/h
ACH 3250 3,250 SCFM≈ 5,522 m³/h
ACH 4050 4,050 SCFM≈ 6,881 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

EVERDRY HOC-P

HOC ISO 2 North America 60 Hz
Flow
500 to 3,600 SCFM (≈ 850 to 6,116 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °F
ISO 8573-1 class
Class 2
Frequency
60 Hz
Voltages
460/3/60
CSA · CRN
n/a · n/a

Models

All models: Type Heat of compression (HOC)Dew point -40 °C (-40 °F)ISO class Class 2Voltage 460/3/60

Model Flow
HOC 500 500 SCFM≈ 850 m³/h
HOC 800 800 SCFM≈ 1,359 m³/h
HOC 1000 1,000 SCFM≈ 1,699 m³/h
HOC 1400 1,400 SCFM≈ 2,379 m³/h
HOC 1700 1,700 SCFM≈ 2,888 m³/h
HOC 2000 2,000 SCFM≈ 3,398 m³/h
HOC 2500 2,500 SCFM≈ 4,248 m³/h
HOC 3000 3,000 SCFM≈ 5,097 m³/h
HOC 3600 3,600 SCFM≈ 6,116 m³/h
Comparable lines (3)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

DRYPOINT HL

? Worldwide

Recorded wording: DRYPOINT HL (série)

Flow
n/aat the manufacturer’s reference conditions
Dew point
n/a
ISO 8573-1 class
n/a
Frequency
n/a
Voltages
n/a
CSA · CRN
n/a · n/a
Sources

Models

Models (flow, dew point and conditions of each model number) will be added from the brochures.

Comparable lines (0)

No comparable line in the current data.

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

Equivalent equipment at Onyx M3

Purestream (Friulair) refrigerated dryers, distributed by Onyx M3 Inc.

Is your product missing?