Comparison · Air dryers

Altec AIR air dryers

12 refrigerated, desiccant lines (non-cycling, blower purge, heatless, heated purge), from the manufacturer’s brochures.

Under construction. This comparison tool is still being built: do not base a purchasing decision on this data. Always confirm with your local distributors.

RAD / RHT / UA / DX

NON-CYC ISO 4–6 North America
Flow
10 to 2,000 SCFM (≈ 17 to 3,398 m³/h)at the manufacturer’s reference conditions
Dew point
n/aISO class 4–5 (RHT: class 6)
ISO 8573-1 class
Classes 4, 5, 6
Frequency
n/a
Voltages
n/a
CSA · CRN
n/a · n/a
Features
High inlet temperature · Digital scroll compressor

Models

All models: Voltage 115/1/60; 208-230/1/60; 230/3/60; 460/3/60; 575/3/60 (by model)

Model Flow TypeConditionsISO class
RHT-0010RHT 10 SCFM≈ 17 m³/h Non-cycling · High inlet temperature@175 psig/180 °F inletClass 6
RHT-0015RHT 15 SCFM≈ 25 m³/h Non-cycling · High inlet temperature@175 psig/180 °F inletClass 6
RHT-0020RHT 20 SCFM≈ 34 m³/h Non-cycling · High inlet temperature@175 psig/180 °F inletClass 6
RAD-0025ARAD 25 SCFM≈ 42 m³/h Non-cycling@100 psig/100 °FClass 4 to 5
RHT-0030RHT 30 SCFM≈ 51 m³/h Non-cycling · High inlet temperature@175 psig/180 °F inletClass 6
RAD-0040ARAD 40 SCFM≈ 68 m³/h Non-cycling@100 psig/100 °FClass 4 to 5
RHT-0040RHT 40 SCFM≈ 68 m³/h Non-cycling · High inlet temperature@175 psig/180 °F inletClass 6
RAD-0055ARAD 55 SCFM≈ 93 m³/h Non-cycling@100 psig/100 °FClass 4 to 5
RHT-0060RHT 60 SCFM≈ 102 m³/h Non-cycling · High inlet temperature@175 psig/180 °F inletClass 6
RAD-0075ARAD 75 SCFM≈ 127 m³/h Non-cycling@100 psig/100 °FClass 4 to 5
RHT-0080RHT 80 SCFM≈ 136 m³/h Non-cycling · High inlet temperature@175 psig/180 °F inletClass 6
RAD-0100ARAD 100 SCFM≈ 170 m³/h Non-cycling@100 psig/100 °FClass 4 to 5
RHT-0100RHT 100 SCFM≈ 170 m³/h Non-cycling · High inlet temperature@175 psig/180 °F inletClass 6
RHT-0120RHT 120 SCFM≈ 204 m³/h Non-cycling · High inlet temperature@175 psig/180 °F inletClass 6
RAD-0150ARAD 150 SCFM≈ 255 m³/h Non-cycling@100 psig/100 °FClass 4 to 5
RAD-0200ARAD 200 SCFM≈ 340 m³/h Non-cycling@100 psig/100 °FClass 4 to 5
RAD-0250ARAD 250 SCFM≈ 425 m³/h Non-cycling@100 psig/100 °FClass 4 to 5
RAD-0300ARAD 300 SCFM≈ 510 m³/h Non-cycling@100 psig/100 °FClass 4 to 5
RAD-0400ARAD 400 SCFM≈ 680 m³/h Non-cycling@100 psig/100 °FClass 4 to 5
RAD-0500ARAD 500 SCFM≈ 850 m³/h Non-cycling@100 psig/100 °FClass 4 to 5
RAD-0600ARAD 600 SCFM≈ 1,019 m³/h Non-cycling@100 psig/100 °FClass 4 to 5
RAD-0750ARAD 750 SCFM≈ 1,274 m³/h Non-cycling@100 psig/100 °FClass 4 to 5
RAD-1000ARAD 1,000 SCFM≈ 1,699 m³/h Non-cycling@100 psig/100 °FClass 4 to 5
RAD-1250ARAD 1,250 SCFM≈ 2,124 m³/h Non-cycling@100 psig/100 °FClass 4 to 5
RAD-1500A-MRAD 1,500 SCFM≈ 2,549 m³/h Non-cycling@100 psig/100 °FClass 4 to 5
RAD-2000A-MRAD 2,000 SCFM≈ 3,398 m³/h Non-cycling@100 psig/100 °FClass 4 to 5
RAD-2500A-MRAD 2,500 SCFM≈ 4,248 m³/h Non-cycling@100 psig/100 °FClass 4 to 5
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

MDH

HL ISO 2 ≈ North America
Flow
0.4 to 3.2 SCFM (≈ 1 to 5 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °F/C
ISO 8573-1 class
Class 2 (derived)
Frequency
n/a
Voltages
120 VAC / 240 VAC / 12 VDC / 24 VDC
CSA · CRN
n/a · n/a

VSA

HL ISO 2 ≈ North America
Flow
2.8 to 12 SCFM (≈ 5 to 20 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °F/C
ISO 8573-1 class
Class 2 (derived)
Frequency
n/a
Voltages
120 VAC / 240 VAC
CSA · CRN
n/a · n/a

HR

HL ISO 2 North America
Flow
3 to 50 SCFM (≈ 5 to 85 m³/h)at the manufacturer’s reference conditions
Dew point
-73.3 to -40 °C (-99.9 to -40 °F)-40 °F/C std (-100 °F optional)
ISO 8573-1 class
Class 2
Frequency
n/a
Voltages
120 VAC / 240 VAC / 12 VDC / 24 VDC
CSA · CRN
n/a · n/a

HLD basse PDP

HL ISO 1 North America 60 Hz
Flow
15 to 2,000 SCFM (≈ 25 to 3,398 m³/h)at the manufacturer’s reference conditions
Dew point
-73 °C (-99.4 °F)-100 °F / -73 °C
ISO 8573-1 class
Class 1
Frequency
60 Hz
Voltages
120/1/60
CSA · CRN
n/a · n/a

Models

All models: Type HeatlessDew point -73 °C (-99.4 °F)ISO class Class 1Voltage 120/1/60

Model Flow
HLD-0015-1 15 SCFM≈ 25 m³/h
HLD-0025-1 25 SCFM≈ 42 m³/h
HLD-0050-1 50 SCFM≈ 85 m³/h
HLD-0075-1 75 SCFM≈ 127 m³/h
HLD-0100-1 100 SCFM≈ 170 m³/h
HLD-0130-1 130 SCFM≈ 221 m³/h
HLD-0200-1 200 SCFM≈ 340 m³/h
HLD-0300-1 300 SCFM≈ 510 m³/h
HLD-0400-1 400 SCFM≈ 680 m³/h
HLD-0550-1 550 SCFM≈ 934 m³/h
HLD-0650-1 650 SCFM≈ 1,104 m³/h
HLD-0800-1 800 SCFM≈ 1,359 m³/h
HLD-1000-1 1,000 SCFM≈ 1,699 m³/h
HLD-1250-1 1,250 SCFM≈ 2,124 m³/h
HLD-1500-1 1,500 SCFM≈ 2,549 m³/h
HLD-2000-1 2,000 SCFM≈ 3,398 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

HOF oil field

HL ISO 2 North America 60 Hz CRN
Flow
15 to 800 SCFM (≈ 25 to 1,359 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °F/C (class 2)
ISO 8573-1 class
Class 2
Frequency
60 Hz
Voltages
120/1/60
CSA · CRN
n/a · yes (HOF-0100 to 0800)

HRL

HL ISO 2 North America 60 Hz CRN
Flow
15 to 5,000 SCFM (≈ 25 to 8,495 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °F/C (class 2)
ISO 8573-1 class
Class 2
Frequency
60 Hz
Voltages
120/1/60
CSA · CRN
n/a · yes

Models

All models: Type HeatlessDew point -40 °C (-40 °F)ISO class Class 2Voltage 120/1/60

Model Flow
HRL-0015-1 15 SCFM≈ 25 m³/h
HRL-0025-1 25 SCFM≈ 42 m³/h
HRL-0040-1 40 SCFM≈ 68 m³/h
HRL-0050-1 50 SCFM≈ 85 m³/h
HRL-0075-1 75 SCFM≈ 127 m³/h
HRL-0100-1 100 SCFM≈ 170 m³/h
HRL-0130-1 130 SCFM≈ 221 m³/h
HRL-0200-1 200 SCFM≈ 340 m³/h
HRL-0250-1 250 SCFM≈ 425 m³/h
HRL-0300-1 300 SCFM≈ 510 m³/h
HRL-0400-1 400 SCFM≈ 680 m³/h
HRL-0550-1 550 SCFM≈ 934 m³/h
HRL-0650-1 650 SCFM≈ 1,104 m³/h
HRL-0800-1 800 SCFM≈ 1,359 m³/h
HRL-1000-1 1,000 SCFM≈ 1,699 m³/h
HRL-1250-1 1,250 SCFM≈ 2,124 m³/h
HRL-1500-1 1,500 SCFM≈ 2,549 m³/h
HRL-2000-1 2,000 SCFM≈ 3,398 m³/h
HRL-2500-1 2,500 SCFM≈ 4,248 m³/h
HRL-3000-1 3,000 SCFM≈ 5,097 m³/h
HRL-4000-1 4,000 SCFM≈ 6,796 m³/h
HRL-5000-1 5,000 SCFM≈ 8,495 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

HHP high pressure

HL ISO 2 North America 60 Hz CRN
Flow
25 to 1,800 SCFM (≈ 42 to 3,058 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °F/C (class 2)
ISO 8573-1 class
Class 2
Frequency
60 Hz
Voltages
120/1/60
CSA · CRN
n/a · yes
Features
High pressure

Models

All models: Type Heatless · High pressureDew point -40 °C (-40 °F)ISO class Class 2Voltage 120/1/60

Model Flow
HHP-0250-0025-1 25 SCFM≈ 42 m³/h
HHP-0500-0050-1 50 SCFM≈ 85 m³/h
HHP-0250-0055-1 55 SCFM≈ 93 m³/h
HHP-1000-0075-1 75 SCFM≈ 127 m³/h
HHP-0500-0095-1 95 SCFM≈ 161 m³/h
HHP-1000-0130-1 130 SCFM≈ 221 m³/h
HHP-0250-0140-1 140 SCFM≈ 238 m³/h
HHP-0500-0200-1 200 SCFM≈ 340 m³/h
HHP-0250-0250-1 250 SCFM≈ 425 m³/h
HHP-1000-0250-1 250 SCFM≈ 425 m³/h
HHP-0500-0350-1 350 SCFM≈ 595 m³/h
HHP-0250-0390-1 390 SCFM≈ 663 m³/h
HHP-1000-0400-1 400 SCFM≈ 680 m³/h
HHP-0500-0550-1 550 SCFM≈ 934 m³/h
HHP-0250-0570-1 570 SCFM≈ 968 m³/h
HHP-1000-0750-1 750 SCFM≈ 1,274 m³/h
HHP-0500-0800-1 800 SCFM≈ 1,359 m³/h
HHP-0250-1000-1 1,000 SCFM≈ 1,699 m³/h
HHP-1000-1000-1 1,000 SCFM≈ 1,699 m³/h
HHP-0500-1400-1 1,400 SCFM≈ 2,379 m³/h
HHP-1000-1800-1 1,800 SCFM≈ 3,058 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

MHR

HL ISO 1–2 ≈ North America 60 Hz 50 Hz CRN
Flow
75 to 3,000 SCFM (≈ 127 to 5,097 m³/h)at the manufacturer’s reference conditions
Dew point
-73.3 to -40 °C (-99.9 to -40 °F)-40 °F/C or -100 °F (selectable)
ISO 8573-1 class
Class 1 to 2 (derived)
Frequency
50 Hz · 60 Hz
Voltages
115/1/50-60
CSA · CRN
n/a · yes

Models

All models: Type HeatlessDew point -73.3 to -40 °C (-99.9 to -40 °F)ISO class Class 1 to 2 (derived)Voltage 115/1/50-60

Model Flow
MHR75 75 SCFM≈ 127 m³/h
MHR100 100 SCFM≈ 170 m³/h
MHR125 125 SCFM≈ 212 m³/h
MHR150 150 SCFM≈ 255 m³/h
MHR200 200 SCFM≈ 340 m³/h
MHR250 250 SCFM≈ 425 m³/h
MHR350 350 SCFM≈ 595 m³/h
MHR520 520 SCFM≈ 883 m³/h
MHR620 620 SCFM≈ 1,053 m³/h
MHR800 800 SCFM≈ 1,359 m³/h
MHR1000 1,000 SCFM≈ 1,699 m³/h
MHR1200 1,200 SCFM≈ 2,039 m³/h
MHR1600 1,600 SCFM≈ 2,718 m³/h
MHR2000 2,000 SCFM≈ 3,398 m³/h
MHR3000 3,000 SCFM≈ 5,097 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

HBS

BP ISO 2–4 ≈ North America 60 Hz
Flow
60 to 3,000 SCFM (≈ 102 to 5,097 m³/h)at the manufacturer’s reference conditions
Dew point
-45.6 to -17.8 °C (-50.1 to -0 °F)0 to -50 °F
ISO 8573-1 class
Classes 2, 4 (derived)
Frequency
60 Hz
Voltages
120/1/60 · 208-230/1/60 · 460/3/60
CSA · CRN
n/a · n/a

Models

All models: Type Blower purgeDew point -45.6 to -17.8 °C (-50.1 to -0 °F)ISO class Classes 2, 4 (derived)

Model Flow Voltage
HBS-0060-1 60 SCFM≈ 102 m³/h 120/1/60
HBS-0100-1 100 SCFM≈ 170 m³/h 120/1/60
HBS-0150-1 150 SCFM≈ 255 m³/h 120/1/60
HBS-0200-2 200 SCFM≈ 340 m³/h 208-230/1/60
HBS-0250-2 250 SCFM≈ 425 m³/h 208-230/1/60
HBS-0300-4 300 SCFM≈ 510 m³/h 460/3/60
HBS-0400-4 400 SCFM≈ 680 m³/h 460/3/60
HBS-0500-4 500 SCFM≈ 850 m³/h 460/3/60
HBS-0650-4 650 SCFM≈ 1,104 m³/h 460/3/60
HBS-0800-4 800 SCFM≈ 1,359 m³/h 460/3/60
HBS-1000-4 1,000 SCFM≈ 1,699 m³/h 460/3/60
HBS-1250-4 1,250 SCFM≈ 2,124 m³/h 460/3/60
HBS-1600-4 1,600 SCFM≈ 2,718 m³/h 460/3/60
HBS-2100-4 2,100 SCFM≈ 3,568 m³/h 460/3/60
HBS-2600-4 2,600 SCFM≈ 4,417 m³/h 460/3/60
HBS-3000-4 3,000 SCFM≈ 5,097 m³/h 460/3/60
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

HBP

BP ISO 2 North America 60 Hz CRN
Flow
100 to 6,000 SCFM (≈ 170 to 10,194 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °F/C (class 2)
ISO 8573-1 class
Class 2
Frequency
60 Hz
Voltages
120/1/60 · 208-230/1/60 · 460/3/60
CSA · CRN
n/a · yes

Models

All models: Type Blower purgeDew point -40 °C (-40 °F)ISO class Class 2

Model Flow Voltage
HBP-0100-1 100 SCFM≈ 170 m³/h 120/1/60
HBP-0130-1 130 SCFM≈ 221 m³/h 120/1/60
HBP-0200-2 200 SCFM≈ 340 m³/h 208-230/1/60
HBP-0250-4 250 SCFM≈ 425 m³/h 460/3/60
HBP-0300-4 300 SCFM≈ 510 m³/h 460/3/60
HBP-0400-4 400 SCFM≈ 680 m³/h 460/3/60
HBP-0550-4 550 SCFM≈ 934 m³/h 460/3/60
HBP-0650-4 650 SCFM≈ 1,104 m³/h 460/3/60
HBP-0800-4 800 SCFM≈ 1,359 m³/h 460/3/60
HBP-1000-4 1,000 SCFM≈ 1,699 m³/h 460/3/60
HBP-1250-4 1,250 SCFM≈ 2,124 m³/h 460/3/60
HBP-1500-4 1,500 SCFM≈ 2,549 m³/h 460/3/60
HBP-2000-4 2,000 SCFM≈ 3,398 m³/h 460/3/60
HBP-2500-4 2,500 SCFM≈ 4,248 m³/h 460/3/60
HBP-3000-4 3,000 SCFM≈ 5,097 m³/h 460/3/60
HBP-4000-4 4,000 SCFM≈ 6,796 m³/h 460/3/60
HBP-5000-4 5,000 SCFM≈ 8,495 m³/h 460/3/60
HBP-6000-4 6,000 SCFM≈ 10,194 m³/h 460/3/60
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

HRE

EH ISO 2 North America 60 Hz CRN
Flow
100 to 6,000 SCFM (≈ 170 to 10,194 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °F/C (class 2)
ISO 8573-1 class
Class 2
Frequency
60 Hz
Voltages
120/1/60 · 208-230/1/60 · 460/3/60
CSA · CRN
n/a · yes

Models

All models: Type Heated purgeDew point -40 °C (-40 °F)ISO class Class 2

Model Flow Voltage
HRE-0100-1 100 SCFM≈ 170 m³/h 120/1/60
HRE-0130-1 130 SCFM≈ 221 m³/h 120/1/60
HRE-0200-2 200 SCFM≈ 340 m³/h 208-230/1/60
HRE-0250-4 250 SCFM≈ 425 m³/h 460/3/60
HRE-0300-4 300 SCFM≈ 510 m³/h 460/3/60
HRE-0400-4 400 SCFM≈ 680 m³/h 460/3/60
HRE-0550-4 550 SCFM≈ 934 m³/h 460/3/60
HRE-0650-4 650 SCFM≈ 1,104 m³/h 460/3/60
HRE-0800-4 800 SCFM≈ 1,359 m³/h 460/3/60
HRE-1000-4 1,000 SCFM≈ 1,699 m³/h 460/3/60
HRE-1250-4 1,250 SCFM≈ 2,124 m³/h 460/3/60
HRE-1500-4 1,500 SCFM≈ 2,549 m³/h 460/3/60
HRE-2000-4 2,000 SCFM≈ 3,398 m³/h 460/3/60
HRE-2500-4 2,500 SCFM≈ 4,248 m³/h 460/3/60
HRE-3000-4 3,000 SCFM≈ 5,097 m³/h 460/3/60
HRE-4000-4 4,000 SCFM≈ 6,796 m³/h 460/3/60
HRE-5000-4 5,000 SCFM≈ 8,495 m³/h 460/3/60
HRE-6000-4 6,000 SCFM≈ 10,194 m³/h 460/3/60
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

Equivalent equipment at Onyx M3

Purestream (Friulair) refrigerated dryers, distributed by Onyx M3 Inc.

Is your product missing?