Comparison · Air dryers
Altec AIR air dryers
12 refrigerated, desiccant lines (non-cycling, blower purge, heatless, heated purge), from the manufacturer’s brochures.
Under construction. This comparison tool is still being built: do not base a purchasing decision on this data. Always confirm with your local distributors.
All manufacturers Search by need (refrigerated)Search by need (desiccant)
RAD / RHT / UA / DX
- Flow
- 10 to 2,000 SCFM (≈ 17 to 3,398 m³/h)at the manufacturer’s reference conditions
- Dew point
- n/aISO class 4–5 (RHT: class 6)
- ISO 8573-1 class
- Classes 4, 5, 6
- Frequency
- n/a
- Voltages
- n/a
- CSA · CRN
- n/a · n/a
- Features
- High inlet temperature · Digital scroll compressor
Models
All models: Voltage 115/1/60; 208-230/1/60; 230/3/60; 460/3/60; 575/3/60 (by model)
| Model | Flow | Type | Conditions | ISO class |
|---|---|---|---|---|
| RHT-0010RHT | 10 SCFM≈ 17 m³/h | Non-cycling · High inlet temperature | @175 psig/180 °F inlet | Class 6 |
| RHT-0015RHT | 15 SCFM≈ 25 m³/h | Non-cycling · High inlet temperature | @175 psig/180 °F inlet | Class 6 |
| RHT-0020RHT | 20 SCFM≈ 34 m³/h | Non-cycling · High inlet temperature | @175 psig/180 °F inlet | Class 6 |
| RAD-0025ARAD | 25 SCFM≈ 42 m³/h | Non-cycling | @100 psig/100 °F | Class 4 to 5 |
| RHT-0030RHT | 30 SCFM≈ 51 m³/h | Non-cycling · High inlet temperature | @175 psig/180 °F inlet | Class 6 |
| RAD-0040ARAD | 40 SCFM≈ 68 m³/h | Non-cycling | @100 psig/100 °F | Class 4 to 5 |
| RHT-0040RHT | 40 SCFM≈ 68 m³/h | Non-cycling · High inlet temperature | @175 psig/180 °F inlet | Class 6 |
| RAD-0055ARAD | 55 SCFM≈ 93 m³/h | Non-cycling | @100 psig/100 °F | Class 4 to 5 |
| RHT-0060RHT | 60 SCFM≈ 102 m³/h | Non-cycling · High inlet temperature | @175 psig/180 °F inlet | Class 6 |
| RAD-0075ARAD | 75 SCFM≈ 127 m³/h | Non-cycling | @100 psig/100 °F | Class 4 to 5 |
| RHT-0080RHT | 80 SCFM≈ 136 m³/h | Non-cycling · High inlet temperature | @175 psig/180 °F inlet | Class 6 |
| RAD-0100ARAD | 100 SCFM≈ 170 m³/h | Non-cycling | @100 psig/100 °F | Class 4 to 5 |
| RHT-0100RHT | 100 SCFM≈ 170 m³/h | Non-cycling · High inlet temperature | @175 psig/180 °F inlet | Class 6 |
| RHT-0120RHT | 120 SCFM≈ 204 m³/h | Non-cycling · High inlet temperature | @175 psig/180 °F inlet | Class 6 |
| RAD-0150ARAD | 150 SCFM≈ 255 m³/h | Non-cycling | @100 psig/100 °F | Class 4 to 5 |
| RAD-0200ARAD | 200 SCFM≈ 340 m³/h | Non-cycling | @100 psig/100 °F | Class 4 to 5 |
| RAD-0250ARAD | 250 SCFM≈ 425 m³/h | Non-cycling | @100 psig/100 °F | Class 4 to 5 |
| RAD-0300ARAD | 300 SCFM≈ 510 m³/h | Non-cycling | @100 psig/100 °F | Class 4 to 5 |
| RAD-0400ARAD | 400 SCFM≈ 680 m³/h | Non-cycling | @100 psig/100 °F | Class 4 to 5 |
| RAD-0500ARAD | 500 SCFM≈ 850 m³/h | Non-cycling | @100 psig/100 °F | Class 4 to 5 |
| RAD-0600ARAD | 600 SCFM≈ 1,019 m³/h | Non-cycling | @100 psig/100 °F | Class 4 to 5 |
| RAD-0750ARAD | 750 SCFM≈ 1,274 m³/h | Non-cycling | @100 psig/100 °F | Class 4 to 5 |
| RAD-1000ARAD | 1,000 SCFM≈ 1,699 m³/h | Non-cycling | @100 psig/100 °F | Class 4 to 5 |
| RAD-1250ARAD | 1,250 SCFM≈ 2,124 m³/h | Non-cycling | @100 psig/100 °F | Class 4 to 5 |
| RAD-1500A-MRAD | 1,500 SCFM≈ 2,549 m³/h | Non-cycling | @100 psig/100 °F | Class 4 to 5 |
| RAD-2000A-MRAD | 2,000 SCFM≈ 3,398 m³/h | Non-cycling | @100 psig/100 °F | Class 4 to 5 |
| RAD-2500A-MRAD | 2,500 SCFM≈ 4,248 m³/h | Non-cycling | @100 psig/100 °F | Class 4 to 5 |
Comparable lines (8)
- BEKO Technologies DRYPOINT RA III
- Ingersoll Rand D-IN / D-IT
- Atlas Copco FX 1-21
- Atlas Copco FD / FD VSD / FX
- Sullair SRN / SRD
- BOGE DS-2
- Mikropor MKE
- BEKO Technologies DRYPOINT RX / RA
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
MDH
- Flow
- 0.4 to 3.2 SCFM (≈ 1 to 5 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °F/C
- ISO 8573-1 class
- Class 2 (derived)
- Frequency
- n/a
- Voltages
- 120 VAC / 240 VAC / 12 VDC / 24 VDC
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessDew point -40 °C (-40 °F)ISO class Class 2 (derived)Voltage 120 VAC / 240 VAC / 12 VDC / 24 VDC
Comparable lines (8)
- OMI HL (low flow)
- Atlas Copco CD 1-5
- Donaldson Ultrapac 2000 Mini
- Parker PNEUDRI MiDAS
- Ingersoll Rand DA…IM (modular)
- Deltech DHDM (modular)
- Hankison PHDM (modular)
- ZEKS ZMA (modular)
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
VSA
- Flow
- 2.8 to 12 SCFM (≈ 5 to 20 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °F/C
- ISO 8573-1 class
- Class 2 (derived)
- Frequency
- n/a
- Voltages
- 120 VAC / 240 VAC
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessDew point -40 °C (-40 °F)ISO class Class 2 (derived)Voltage 120 VAC / 240 VAC
Comparable lines (8)
- Donaldson Ultrapac 2000 Mini
- Atlas Copco CD 1-5
- Parker PNEUDRI MiDAS
- OMI HL (low flow)
- ALUP AD 7-60
- Worthington Creyssensac DB 05-6
- Chicago Pneumatic CPADM (modular)
- MTA DryXtreme NA
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
HR
- Flow
- 3 to 50 SCFM (≈ 5 to 85 m³/h)at the manufacturer’s reference conditions
- Dew point
- -73.3 to -40 °C (-99.9 to -40 °F)-40 °F/C std (-100 °F optional)
- ISO 8573-1 class
- Class 2
- Frequency
- n/a
- Voltages
- 120 VAC / 240 VAC / 12 VDC / 24 VDC
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessDew point -73.3 to -40 °C (-99.9 to -40 °F)ISO class Class 2Voltage 120 VAC / 240 VAC / 12 VDC / 24 VDC
Comparable lines (8)
- ALUP AD 7-60
- Worthington Creyssensac DB 05-6
- Chicago Pneumatic CPADM (modular)
- MTA DryXtreme NA
- Kaeser DC-HF
- Parker PNEUDRI MiDAS
- BEKO Technologies DRYPOINT AC 119-196
- BEKO Technologies DRYPOINT ACC
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
HLD basse PDP
- Flow
- 15 to 2,000 SCFM (≈ 25 to 3,398 m³/h)at the manufacturer’s reference conditions
- Dew point
- -73 °C (-99.4 °F)-100 °F / -73 °C
- ISO 8573-1 class
- Class 1
- Frequency
- 60 Hz
- Voltages
- 120/1/60
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessDew point -73 °C (-99.4 °F)ISO class Class 1Voltage 120/1/60
| Model | Flow |
|---|---|
| HLD-0015-1 | 15 SCFM≈ 25 m³/h |
| HLD-0025-1 | 25 SCFM≈ 42 m³/h |
| HLD-0050-1 | 50 SCFM≈ 85 m³/h |
| HLD-0075-1 | 75 SCFM≈ 127 m³/h |
| HLD-0100-1 | 100 SCFM≈ 170 m³/h |
| HLD-0130-1 | 130 SCFM≈ 221 m³/h |
| HLD-0200-1 | 200 SCFM≈ 340 m³/h |
| HLD-0300-1 | 300 SCFM≈ 510 m³/h |
| HLD-0400-1 | 400 SCFM≈ 680 m³/h |
| HLD-0550-1 | 550 SCFM≈ 934 m³/h |
| HLD-0650-1 | 650 SCFM≈ 1,104 m³/h |
| HLD-0800-1 | 800 SCFM≈ 1,359 m³/h |
| HLD-1000-1 | 1,000 SCFM≈ 1,699 m³/h |
| HLD-1250-1 | 1,250 SCFM≈ 2,124 m³/h |
| HLD-1500-1 | 1,500 SCFM≈ 2,549 m³/h |
| HLD-2000-1 | 2,000 SCFM≈ 3,398 m³/h |
Comparable lines (8)
- ALUP AD 90-940
- Worthington Creyssensac DB 90-940
- BEKO Technologies DRYPOINT AC 410-495
- Pneumatic Products (SPX) CDA Heat-Les
- Ultrafilter HeatLess HL
- BEKO Technologies DRYPOINT AC HP
- Pneumatech PH 55-310 HE (US)
- FINI HDT
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
HOF oil field
- Flow
- 15 to 800 SCFM (≈ 25 to 1,359 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °F/C (class 2)
- ISO 8573-1 class
- Class 2
- Frequency
- 60 Hz
- Voltages
- 120/1/60
- CSA · CRN
- n/a · yes (HOF-0100 to 0800)
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessDew point -40 °C (-40 °F)ISO class Class 2Voltage 120/1/60
| Model | Flow |
|---|---|
| HOF-0015-1 | 15 SCFM≈ 25 m³/h |
| HOF-0025-1 | 25 SCFM≈ 42 m³/h |
| HOF-0040-1 | 40 SCFM≈ 68 m³/h |
| HOF-0075-1 | 75 SCFM≈ 127 m³/h |
| HOF-0100-1 | 100 SCFM≈ 170 m³/h |
| HOF-0125-1 | 125 SCFM≈ 212 m³/h |
| HOF-0200-1 | 200 SCFM≈ 340 m³/h |
| HOF-0250-1 | 250 SCFM≈ 425 m³/h |
| HOF-0300-1 | 300 SCFM≈ 510 m³/h |
| HOF-0400-1 | 400 SCFM≈ 680 m³/h |
| HOF-0500-1 | 500 SCFM≈ 850 m³/h |
| HOF-0600-1 | 600 SCFM≈ 1,019 m³/h |
| HOF-0800-1 | 800 SCFM≈ 1,359 m³/h |
Comparable lines (8)
- Pneumatech PH 55-310 HE (US)
- MTA DryXtreme NDA (molecular sieve)
- BEKO Technologies DRYPOINT AC HP
- Ultrafilter HeatLess HL
- Atlas Copco CD+ 5-335
- Hertz Kompressoren HHD 16-20 bar
- ALUP AD 90-940
- Worthington Creyssensac DB 90-940
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
HRL
- Flow
- 15 to 5,000 SCFM (≈ 25 to 8,495 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °F/C (class 2)
- ISO 8573-1 class
- Class 2
- Frequency
- 60 Hz
- Voltages
- 120/1/60
- CSA · CRN
- n/a · yes
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessDew point -40 °C (-40 °F)ISO class Class 2Voltage 120/1/60
| Model | Flow |
|---|---|
| HRL-0015-1 | 15 SCFM≈ 25 m³/h |
| HRL-0025-1 | 25 SCFM≈ 42 m³/h |
| HRL-0040-1 | 40 SCFM≈ 68 m³/h |
| HRL-0050-1 | 50 SCFM≈ 85 m³/h |
| HRL-0075-1 | 75 SCFM≈ 127 m³/h |
| HRL-0100-1 | 100 SCFM≈ 170 m³/h |
| HRL-0130-1 | 130 SCFM≈ 221 m³/h |
| HRL-0200-1 | 200 SCFM≈ 340 m³/h |
| HRL-0250-1 | 250 SCFM≈ 425 m³/h |
| HRL-0300-1 | 300 SCFM≈ 510 m³/h |
| HRL-0400-1 | 400 SCFM≈ 680 m³/h |
| HRL-0550-1 | 550 SCFM≈ 934 m³/h |
| HRL-0650-1 | 650 SCFM≈ 1,104 m³/h |
| HRL-0800-1 | 800 SCFM≈ 1,359 m³/h |
| HRL-1000-1 | 1,000 SCFM≈ 1,699 m³/h |
| HRL-1250-1 | 1,250 SCFM≈ 2,124 m³/h |
| HRL-1500-1 | 1,500 SCFM≈ 2,549 m³/h |
| HRL-2000-1 | 2,000 SCFM≈ 3,398 m³/h |
| HRL-2500-1 | 2,500 SCFM≈ 4,248 m³/h |
| HRL-3000-1 | 3,000 SCFM≈ 5,097 m³/h |
| HRL-4000-1 | 4,000 SCFM≈ 6,796 m³/h |
| HRL-5000-1 | 5,000 SCFM≈ 8,495 m³/h |
Comparable lines (8)
- BEKO Technologies DRYPOINT XCe
- Sullivan-Palatek SPDP Pro Heatless
- Pneumatech PH 90-690 HE (solid desiccant)
- FINI HDT
- Pneumatic Products (SPX) DHA Heat-Les
- Parker PNEUDRI DH MAXI
- Chicago Pneumatic CPAD
- Van Air Systems HLSXG (antidéflagrant, gaz naturel)
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
HHP high pressure
- Flow
- 25 to 1,800 SCFM (≈ 42 to 3,058 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °F/C (class 2)
- ISO 8573-1 class
- Class 2
- Frequency
- 60 Hz
- Voltages
- 120/1/60
- CSA · CRN
- n/a · yes
- Features
- High pressure
- Sources
- Manufacturer’s page
Models
All models: Type Heatless · High pressureDew point -40 °C (-40 °F)ISO class Class 2Voltage 120/1/60
| Model | Flow |
|---|---|
| HHP-0250-0025-1 | 25 SCFM≈ 42 m³/h |
| HHP-0500-0050-1 | 50 SCFM≈ 85 m³/h |
| HHP-0250-0055-1 | 55 SCFM≈ 93 m³/h |
| HHP-1000-0075-1 | 75 SCFM≈ 127 m³/h |
| HHP-0500-0095-1 | 95 SCFM≈ 161 m³/h |
| HHP-1000-0130-1 | 130 SCFM≈ 221 m³/h |
| HHP-0250-0140-1 | 140 SCFM≈ 238 m³/h |
| HHP-0500-0200-1 | 200 SCFM≈ 340 m³/h |
| HHP-0250-0250-1 | 250 SCFM≈ 425 m³/h |
| HHP-1000-0250-1 | 250 SCFM≈ 425 m³/h |
| HHP-0500-0350-1 | 350 SCFM≈ 595 m³/h |
| HHP-0250-0390-1 | 390 SCFM≈ 663 m³/h |
| HHP-1000-0400-1 | 400 SCFM≈ 680 m³/h |
| HHP-0500-0550-1 | 550 SCFM≈ 934 m³/h |
| HHP-0250-0570-1 | 570 SCFM≈ 968 m³/h |
| HHP-1000-0750-1 | 750 SCFM≈ 1,274 m³/h |
| HHP-0500-0800-1 | 800 SCFM≈ 1,359 m³/h |
| HHP-0250-1000-1 | 1,000 SCFM≈ 1,699 m³/h |
| HHP-1000-1000-1 | 1,000 SCFM≈ 1,699 m³/h |
| HHP-0500-1400-1 | 1,400 SCFM≈ 2,379 m³/h |
| HHP-1000-1800-1 | 1,800 SCFM≈ 3,058 m³/h |
Comparable lines (8)
- Van Air Systems HLSXG (antidéflagrant, gaz naturel)
- Pneumatic Products (SPX) CDA Heat-Les
- BEKO Technologies DRYPOINT AC 410-495
- FINI HDT
- Pneumatech PH 90-690 HE (solid desiccant)
- MTA DryXtreme NDA (alumina)
- BEKO Technologies DRYPOINT XCe
- Sullivan-Palatek SPDP Pro Heatless
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
MHR
- Flow
- 75 to 3,000 SCFM (≈ 127 to 5,097 m³/h)at the manufacturer’s reference conditions
- Dew point
- -73.3 to -40 °C (-99.9 to -40 °F)-40 °F/C or -100 °F (selectable)
- ISO 8573-1 class
- Class 1 to 2 (derived)
- Frequency
- 50 Hz · 60 Hz
- Voltages
- 115/1/50-60
- CSA · CRN
- n/a · yes
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessDew point -73.3 to -40 °C (-99.9 to -40 °F)ISO class Class 1 to 2 (derived)Voltage 115/1/50-60
| Model | Flow |
|---|---|
| MHR75 | 75 SCFM≈ 127 m³/h |
| MHR100 | 100 SCFM≈ 170 m³/h |
| MHR125 | 125 SCFM≈ 212 m³/h |
| MHR150 | 150 SCFM≈ 255 m³/h |
| MHR200 | 200 SCFM≈ 340 m³/h |
| MHR250 | 250 SCFM≈ 425 m³/h |
| MHR350 | 350 SCFM≈ 595 m³/h |
| MHR520 | 520 SCFM≈ 883 m³/h |
| MHR620 | 620 SCFM≈ 1,053 m³/h |
| MHR800 | 800 SCFM≈ 1,359 m³/h |
| MHR1000 | 1,000 SCFM≈ 1,699 m³/h |
| MHR1200 | 1,200 SCFM≈ 2,039 m³/h |
| MHR1600 | 1,600 SCFM≈ 2,718 m³/h |
| MHR2000 | 2,000 SCFM≈ 3,398 m³/h |
| MHR3000 | 3,000 SCFM≈ 5,097 m³/h |
Comparable lines (8)
- BEKO Technologies DRYPOINT XCp
- Sullivan-Palatek SPDPR Premium Heatless
- Champion CDT
- Gardner Denver DGH
- Hankison HHX
- Hankison HHS
- Hankison HHL
- Kaeser KAD
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
HBS
- Flow
- 60 to 3,000 SCFM (≈ 102 to 5,097 m³/h)at the manufacturer’s reference conditions
- Dew point
- -45.6 to -17.8 °C (-50.1 to -0 °F)0 to -50 °F
- ISO 8573-1 class
- Classes 2, 4 (derived)
- Frequency
- 60 Hz
- Voltages
- 120/1/60 · 208-230/1/60 · 460/3/60
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Blower purgeDew point -45.6 to -17.8 °C (-50.1 to -0 °F)ISO class Classes 2, 4 (derived)
| Model | Flow | Voltage |
|---|---|---|
| HBS-0060-1 | 60 SCFM≈ 102 m³/h | 120/1/60 |
| HBS-0100-1 | 100 SCFM≈ 170 m³/h | 120/1/60 |
| HBS-0150-1 | 150 SCFM≈ 255 m³/h | 120/1/60 |
| HBS-0200-2 | 200 SCFM≈ 340 m³/h | 208-230/1/60 |
| HBS-0250-2 | 250 SCFM≈ 425 m³/h | 208-230/1/60 |
| HBS-0300-4 | 300 SCFM≈ 510 m³/h | 460/3/60 |
| HBS-0400-4 | 400 SCFM≈ 680 m³/h | 460/3/60 |
| HBS-0500-4 | 500 SCFM≈ 850 m³/h | 460/3/60 |
| HBS-0650-4 | 650 SCFM≈ 1,104 m³/h | 460/3/60 |
| HBS-0800-4 | 800 SCFM≈ 1,359 m³/h | 460/3/60 |
| HBS-1000-4 | 1,000 SCFM≈ 1,699 m³/h | 460/3/60 |
| HBS-1250-4 | 1,250 SCFM≈ 2,124 m³/h | 460/3/60 |
| HBS-1600-4 | 1,600 SCFM≈ 2,718 m³/h | 460/3/60 |
| HBS-2100-4 | 2,100 SCFM≈ 3,568 m³/h | 460/3/60 |
| HBS-2600-4 | 2,600 SCFM≈ 4,417 m³/h | 460/3/60 |
| HBS-3000-4 | 3,000 SCFM≈ 5,097 m³/h | 460/3/60 |
Comparable lines (8)
- Gardner Denver GBPD
- Champion XCHB
- Quincy QBP
- Great Lakes Air GBS
- BEKO Technologies EVERDRY FRL-V
- Ingersoll Rand HB
- Atlas Copco BD+
- Atlas Copco BD+ ZP
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
HBP
- Flow
- 100 to 6,000 SCFM (≈ 170 to 10,194 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °F/C (class 2)
- ISO 8573-1 class
- Class 2
- Frequency
- 60 Hz
- Voltages
- 120/1/60 · 208-230/1/60 · 460/3/60
- CSA · CRN
- n/a · yes
- Sources
- Manufacturer’s page
Models
All models: Type Blower purgeDew point -40 °C (-40 °F)ISO class Class 2
| Model | Flow | Voltage |
|---|---|---|
| HBP-0100-1 | 100 SCFM≈ 170 m³/h | 120/1/60 |
| HBP-0130-1 | 130 SCFM≈ 221 m³/h | 120/1/60 |
| HBP-0200-2 | 200 SCFM≈ 340 m³/h | 208-230/1/60 |
| HBP-0250-4 | 250 SCFM≈ 425 m³/h | 460/3/60 |
| HBP-0300-4 | 300 SCFM≈ 510 m³/h | 460/3/60 |
| HBP-0400-4 | 400 SCFM≈ 680 m³/h | 460/3/60 |
| HBP-0550-4 | 550 SCFM≈ 934 m³/h | 460/3/60 |
| HBP-0650-4 | 650 SCFM≈ 1,104 m³/h | 460/3/60 |
| HBP-0800-4 | 800 SCFM≈ 1,359 m³/h | 460/3/60 |
| HBP-1000-4 | 1,000 SCFM≈ 1,699 m³/h | 460/3/60 |
| HBP-1250-4 | 1,250 SCFM≈ 2,124 m³/h | 460/3/60 |
| HBP-1500-4 | 1,500 SCFM≈ 2,549 m³/h | 460/3/60 |
| HBP-2000-4 | 2,000 SCFM≈ 3,398 m³/h | 460/3/60 |
| HBP-2500-4 | 2,500 SCFM≈ 4,248 m³/h | 460/3/60 |
| HBP-3000-4 | 3,000 SCFM≈ 5,097 m³/h | 460/3/60 |
| HBP-4000-4 | 4,000 SCFM≈ 6,796 m³/h | 460/3/60 |
| HBP-5000-4 | 5,000 SCFM≈ 8,495 m³/h | 460/3/60 |
| HBP-6000-4 | 6,000 SCFM≈ 10,194 m³/h | 460/3/60 |
Comparable lines (8)
- Great Lakes Air GBS
- Quincy QBP
- BEKO Technologies EVERDRY FRL-V
- Champion XCHB
- Gardner Denver GBPD
- Ingersoll Rand HB
- Atlas Copco BD+
- Atlas Copco BD+ ZP
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
HRE
- Flow
- 100 to 6,000 SCFM (≈ 170 to 10,194 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °F/C (class 2)
- ISO 8573-1 class
- Class 2
- Frequency
- 60 Hz
- Voltages
- 120/1/60 · 208-230/1/60 · 460/3/60
- CSA · CRN
- n/a · yes
- Sources
- Manufacturer’s page
Models
All models: Type Heated purgeDew point -40 °C (-40 °F)ISO class Class 2
| Model | Flow | Voltage |
|---|---|---|
| HRE-0100-1 | 100 SCFM≈ 170 m³/h | 120/1/60 |
| HRE-0130-1 | 130 SCFM≈ 221 m³/h | 120/1/60 |
| HRE-0200-2 | 200 SCFM≈ 340 m³/h | 208-230/1/60 |
| HRE-0250-4 | 250 SCFM≈ 425 m³/h | 460/3/60 |
| HRE-0300-4 | 300 SCFM≈ 510 m³/h | 460/3/60 |
| HRE-0400-4 | 400 SCFM≈ 680 m³/h | 460/3/60 |
| HRE-0550-4 | 550 SCFM≈ 934 m³/h | 460/3/60 |
| HRE-0650-4 | 650 SCFM≈ 1,104 m³/h | 460/3/60 |
| HRE-0800-4 | 800 SCFM≈ 1,359 m³/h | 460/3/60 |
| HRE-1000-4 | 1,000 SCFM≈ 1,699 m³/h | 460/3/60 |
| HRE-1250-4 | 1,250 SCFM≈ 2,124 m³/h | 460/3/60 |
| HRE-1500-4 | 1,500 SCFM≈ 2,549 m³/h | 460/3/60 |
| HRE-2000-4 | 2,000 SCFM≈ 3,398 m³/h | 460/3/60 |
| HRE-2500-4 | 2,500 SCFM≈ 4,248 m³/h | 460/3/60 |
| HRE-3000-4 | 3,000 SCFM≈ 5,097 m³/h | 460/3/60 |
| HRE-4000-4 | 4,000 SCFM≈ 6,796 m³/h | 460/3/60 |
| HRE-5000-4 | 5,000 SCFM≈ 8,495 m³/h | 460/3/60 |
| HRE-6000-4 | 6,000 SCFM≈ 10,194 m³/h | 460/3/60 |
Comparable lines (8)
- Mattei MEH
- Champion XCHP
- Deltech RP
- Nano Purification D5 EH (US)
- Hankison HPD
- Kaeser KED
- MTA DryXtreme NST
- Sullivan-Palatek SPDH Pro Heated Purge
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
Equivalent equipment at Onyx M3
Purestream (Friulair) refrigerated dryers, distributed by Onyx M3 Inc.
Is your product missing?
Request received. We will proceed within 72 hours.