Comparison · Air dryers
Kaeser air dryers
7 refrigerated, desiccant lines (cycling, heatless, heated purge, blower purge), from the manufacturer’s brochures.
Under construction. This comparison tool is still being built: do not base a purchasing decision on this data. Always confirm with your local distributors.
All manufacturers Search by need (refrigerated)Search by need (desiccant)
SECOTEC TA / TB / TC
Recorded wording: SECOTEC TA-TB-TC (US)
- Flow
- 20 to 138 SCFM (≈ 34 to 234 m³/h)at the manufacturer’s reference conditions
- Dew point
- 3.3 °C (37.9 °F)PDP 38 °F
- ISO 8573-1 class
- Class 5 (derived)
- Frequency
- 60 Hz
- Voltages
- 115/1/60 · 230/1/60
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type CyclingDew point 3.3 °C (37.9 °F)ISO class Class 5 (derived)
| Model | Flow | Conditions | Voltage |
|---|---|---|---|
| SECOTEC TA 5SECOTEC TA–TC | 20 SCFM≈ 34 m³/h | ISO 7183 A2: 0.30 kW ; 100 psig/100 °F | 115/1/60 |
| SECOTEC TA 8SECOTEC TA–TC | 30 SCFM≈ 51 m³/h | ISO 7183 A2: 0.37 kW ; 100 psig/100 °F | 115/1/60 |
| SECOTEC TA 11SECOTEC TA–TC | 45 SCFM≈ 76 m³/h | ISO 7183 A2: 0.45 kW ; 100 psig/100 °F | 115/1/60 |
| SECOTEC TB 19SECOTEC TA–TC | 74 SCFM≈ 126 m³/h | ISO 7183 A2: 0.60 / 0.52 kW ; 100 psig/100 °F | 115/1/60 or 230/1/60 |
| SECOTEC TB 26SECOTEC TA–TC | 90 SCFM≈ 153 m³/h | ISO 7183 A2: 0.75 / 0.82 kW ; 100 psig/100 °F | 115/1/60 or 230/1/60 |
| SECOTEC TC 31SECOTEC TA–TC | 113 SCFM≈ 192 m³/h | ISO 7183 A2: 0.97 / 1.12 kW ; 100 psig/100 °F | 115/1/60 or 230/1/60 |
| SECOTEC TC 36SECOTEC TA–TC | 138 SCFM≈ 234 m³/h | ISO 7183 A2: 1.04 / 1.19 kW ; 100 psig/100 °F | 115/1/60 or 230/1/60 |
Comparable lines (6)
- Sullivan-Palatek SPR
- Purestream (Friulair) ACT ES
- MTA DE iTECH
- Nano Purification TMC
- Sullair SRN / SRD
- Gardner Denver GDDF-ES
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
SECOTEC TD / TE / TF / TG
Recorded wording: SECOTEC TD-TE-TF-TG (US)
- Flow
- 162 to 3,070 SCFM (≈ 275 to 5,216 m³/h)at the manufacturer’s reference conditions
- Dew point
- n/a
- ISO 8573-1 class
- n/a
- Frequency
- 60 Hz
- Voltages
- 230/1/60 · 208/3/60 · 230/3/60 · 460/3/60 · 575/3/60
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Cycling
| Model | Flow | Conditions | Voltage |
|---|---|---|---|
| SECOTEC TD 52SECOTEC TD–TG | 162 SCFM≈ 275 m³/h | ISO 7183 A2: 0.88 kW ; 100 psig/100 °F | 230/1/60 |
| SECOTEC TD 67SECOTEC TD–TG | 212 SCFM≈ 360 m³/h | ISO 7183 A2: 1.11 kW ; 100 psig/100 °F | 230/1/60 |
| SECOTEC TD 73SECOTEC TD–TG | 244 SCFM≈ 415 m³/h | ISO 7183 A2: 1.16 kW ; 100 psig/100 °F | 230/1/60 |
| SECOTEC TD 94SECOTEC TD–TG | 279 SCFM≈ 474 m³/h | ISO 7183 A2: 1.23 kW ; 100 psig/100 °F | 230/1/60 |
| SECOTEC TE 120SECOTEC TD–TG | 388 SCFM≈ 659 m³/h | ISO 7183 A2: 1.6 kW ; 100 psig/100 °F | 208/230/460/575 V 3/60 |
| SECOTEC TE 143SECOTEC TD–TG | 452 SCFM≈ 768 m³/h | ISO 7183 A2: 1.7 kW ; 100 psig/100 °F | 208/230/460/575 V 3/60 |
| SECOTEC TE 155SECOTEC TD–TG | 487 SCFM≈ 827 m³/h | ISO 7183 A2: 1.9 kW ; 100 psig/100 °F | 208/230/460/575 V 3/60 |
| SECOTEC TF 174SECOTEC TD–TG | 550 SCFM≈ 934 m³/h | ISO 7183 A2: 2.5 kW ; 100 psig/100 °F | 208/230/460/575 V 3/60 |
| SECOTEC TF 230SECOTEC TD–TG | 740 SCFM≈ 1,257 m³/h | ISO 7183 A2: 3.7 kW ; 100 psig/100 °F | 208/230/460/575 V 3/60 |
| SECOTEC TF 280SECOTEC TD–TG | 900 SCFM≈ 1,529 m³/h | ISO 7183 A2: 4.2 kW ; 100 psig/100 °F | 208/230/460/575 V 3/60 |
| SECOTEC TF 340SECOTEC TD–TG | 1,130 SCFM≈ 1,920 m³/h | ISO 7183 A2: 4.5 kW ; 100 psig/100 °F | 208/230/460/575 V 3/60 |
| SECOTEC TG 450SECOTEC TD–TG | 1,340 SCFM≈ 2,277 m³/h | ISO 7183 A2: 5.1 kW ; 100 psig/100 °F | 460/3/60 |
| SECOTEC TG 520SECOTEC TD–TG | 1,550 SCFM≈ 2,633 m³/h | ISO 7183 A2: 6.0 kW ; 100 psig/100 °F | 460/3/60 |
| SECOTEC TG 650SECOTEC TD–TG | 1,910 SCFM≈ 3,245 m³/h | ISO 7183 A2: 7.2 kW ; 100 psig/100 °F | 460/3/60 |
| SECOTEC TG 780SECOTEC TD–TG | 2,330 SCFM≈ 3,959 m³/h | ISO 7183 A2: 9.0 kW ; 100 psig/100 °F | 460/3/60 |
| SECOTEC TG 980SECOTEC TD–TG | 3,070 SCFM≈ 5,216 m³/h | ISO 7183 A2: 14.9 kW ; 100 psig/100 °F | 460/3/60 |
Comparable lines (8)
- ZEKS HeatSink HSH/HSG 300-1600
- Pneumatech AC VSD
- Quincy ECO DRI / QED
- Hertz Kompressoren HRC
- Deltech FLEX
- Parker PoleStar Smart-E PSE
- Gardner Denver GDDF-ES
- Sullair SRN / SRD
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
DC-HF
- Flow
- 7 to 40 SCFM (≈ 12 to 68 m³/h)at the manufacturer’s reference conditions
- Dew point
- -70 to -40 °C (-94 to -40 °F)-40 °F (or -94 °F)
- ISO 8573-1 class
- Class 1 to 2 (derived)
- Frequency
- 50 Hz · 60 Hz
- Voltages
- 120/1/50-60
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessConditions ISO 7183 optional A2 (100 °F, 100 psig)Dew point -70 to -40 °C (-94 to -40 °F)ISO class Class 1 to 2 (derived)Voltage 120/1/50-60
Comparable lines (8)
- MTA DryXtreme NA
- Chicago Pneumatic CPADM (modular)
- BEKO Technologies DRYPOINT ACC
- Ingersoll Rand DA…IM (modular)
- Deltech DHDM (modular)
- Hankison PHDM (modular)
- ZEKS ZMA (modular)
- ALUP AD 7-60
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
KAD
- Flow
- 40 to 5,400 SCFM (≈ 68 to 9,175 m³/h)at the manufacturer’s reference conditions
- Dew point
- -70 to -20 °C (-94 to -4 °F)-40 °F (options -4 °F / -94 °F)
- ISO 8573-1 class
- Classes 1, 2, 3
- Frequency
- n/a
- Voltages
- n/a
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessConditions @100 psigDew point -70 to -20 °C (-94 to -4 °F)ISO class Classes 1, 2, 3
| Model | Flow |
|---|---|
| KAD 40 | 40 SCFM≈ 68 m³/h |
| KAD 60 | 60 SCFM≈ 102 m³/h |
| KAD 90 | 90 SCFM≈ 153 m³/h |
| KAD 115 | 115 SCFM≈ 195 m³/h |
| KAD 165 | 165 SCFM≈ 280 m³/h |
| KAD 260 | 260 SCFM≈ 442 m³/h |
| KAD 370 | 370 SCFM≈ 629 m³/h |
| KAD 450 | 450 SCFM≈ 765 m³/h |
| KAD 590 | 590 SCFM≈ 1,002 m³/h |
| KAD 750 | 750 SCFM≈ 1,274 m³/h |
| KAD 930 | 930 SCFM≈ 1,580 m³/h |
| KAD 1130 | 1,130 SCFM≈ 1,920 m³/h |
| KAD 1350 | 1,350 SCFM≈ 2,294 m³/h |
| KAD 1550 | 1,550 SCFM≈ 2,633 m³/h |
| KAD 2100 | 2,100 SCFM≈ 3,568 m³/h |
| KAD 3000 | 3,000 SCFM≈ 5,097 m³/h |
| KAD 4100 | 4,100 SCFM≈ 6,966 m³/h |
| KAD 5400 | 5,400 SCFM≈ 9,175 m³/h |
Comparable lines (8)
- Champion CDT
- Gardner Denver DGH
- Hankison HHX
- Hankison HHS
- Hankison HHL
- BEKO Technologies DRYPOINT XCp
- Sullivan-Palatek SPDPR Premium Heatless
- Altec AIR MHR
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
i.DC 16-1555
- Flow
- 96 to 9,330 m³/h (≈ 57 to 5,491 SCFM)at the manufacturer’s reference conditions
- Dew point
- -70 to 3 °C (-94 to 37.4 °F)-40 °C (options -70 / -20 / +3 °C)
- ISO 8573-1 class
- Class 2
- Frequency
- 50 Hz · 60 Hz
- Voltages
- 100-240/1/50-60
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type HeatlessConditions ISO 7183 optional A1Dew point -70 to 3 °C (-94 to 37.4 °F)ISO class Class 2Voltage 100-240/1/50-60
| Model | Flow |
|---|---|
| i.DC 16 | ≈ 57 SCFM96 m³/h |
| i.DC 23 | ≈ 81 SCFM138 m³/h |
| i.DC 34 | ≈ 120 SCFM204 m³/h |
| i.DC 52 | ≈ 184 SCFM312 m³/h |
| i.DC 67 | ≈ 237 SCFM402 m³/h |
| i.DC 84 | ≈ 297 SCFM504 m³/h |
| i.DC 115 | ≈ 406 SCFM690 m³/h |
| i.DC 140 | ≈ 494 SCFM840 m³/h |
| i.DC 225 | ≈ 795 SCFM1,350 m³/h |
| i.DC 275 | ≈ 971 SCFM1,650 m³/h |
| i.DC 330 | ≈ 1,165 SCFM1,980 m³/h |
| i.DC 395 | ≈ 1,395 SCFM2,370 m³/h |
| i.DC 450 | ≈ 1,589 SCFM2,700 m³/h |
| i.DC 610 | ≈ 2,154 SCFM3,660 m³/h |
| i.DC 870 | ≈ 3,072 SCFM5,220 m³/h |
| i.DC 1190 | ≈ 4,202 SCFM7,140 m³/h |
| i.DC 1555 | ≈ 5,491 SCFM9,330 m³/h |
Comparable lines (8)
- Mattei MHL
- Champion XCHL
- Parker PNEUDRI MX
- Hankison HHL (international)
- MARK ADS 110-215
- ALUP AD 650-1300 (sensor)
- Worthington Creyssensac DB 65-130
- OMI HLA
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
KBD
- Flow
- 500 to 4,300 SCFM (≈ 850 to 7,306 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 °C (-40 °F)-40 °F
- ISO 8573-1 class
- Class 2 (derived)
- Frequency
- n/a
- Voltages
- n/a
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Blower purgeConditions @100 psig 100 °FDew point -40 °C (-40 °F)ISO class Class 2 (derived)
| Model | Flow |
|---|---|
| KBD 500 | 500 SCFM≈ 850 m³/h |
| KBD 600 | 600 SCFM≈ 1,019 m³/h |
| KBD 750 | 750 SCFM≈ 1,274 m³/h |
| KBD 900 | 900 SCFM≈ 1,529 m³/h |
| KBD 1050 | 1,050 SCFM≈ 1,784 m³/h |
| KBD 1300 | 1,300 SCFM≈ 2,209 m³/h |
| KBD 1500 | 1,500 SCFM≈ 2,549 m³/h |
| KBD 1800 | 1,800 SCFM≈ 3,058 m³/h |
| KBD 2200 | 2,200 SCFM≈ 3,738 m³/h |
| KBD 2600 | 2,600 SCFM≈ 4,417 m³/h |
| KBD 3200 | 3,200 SCFM≈ 5,437 m³/h |
| KBD 3600 | 3,600 SCFM≈ 6,116 m³/h |
| KBD 4300 | 4,300 SCFM≈ 7,306 m³/h |
Comparable lines (8)
- Hankison HBP
- Pneumatic Products (SPX) IBP
- Mattei MBP
- Ingersoll Rand D…IBA
- Atlas Copco BD 360-1600
- Nano Purification D5 BP (US)
- Mattei DDH 850-10800
- Atlas Copco BD+
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
KED
- Flow
- 300 to 3,200 SCFM (≈ 510 to 5,437 m³/h)at the manufacturer’s reference conditions
- Dew point
- -40 to -20 °C (-40 to -4 °F)-4 °F (-40 °F with optional booster purge)
- ISO 8573-1 class
- Class 2 to 3 (derived)
- Frequency
- n/a
- Voltages
- n/a
- CSA · CRN
- n/a · n/a
- Sources
- Manufacturer’s page
Models
All models: Type Heated purgeConditions @100 psig 100 °FDew point -40 to -20 °C (-40 to -4 °F)ISO class Class 2 to 3 (derived)
| Model | Flow |
|---|---|
| KED 300 | 300 SCFM≈ 510 m³/h |
| KED 400 | 400 SCFM≈ 680 m³/h |
| KED 500 | 500 SCFM≈ 850 m³/h |
| KED 600 | 600 SCFM≈ 1,019 m³/h |
| KED 750 | 750 SCFM≈ 1,274 m³/h |
| KED 900 | 900 SCFM≈ 1,529 m³/h |
| KED 1050 | 1,050 SCFM≈ 1,784 m³/h |
| KED 1300 | 1,300 SCFM≈ 2,209 m³/h |
| KED 1500 | 1,500 SCFM≈ 2,549 m³/h |
| KED 1800 | 1,800 SCFM≈ 3,058 m³/h |
| KED 2200 | 2,200 SCFM≈ 3,738 m³/h |
| KED 2600 | 2,600 SCFM≈ 4,417 m³/h |
| KED 3200 | 3,200 SCFM≈ 5,437 m³/h |
Comparable lines (8)
- Hankison HPD
- Deltech RP
- Ingersoll Rand EH
- Sullair SAH
- Altec AIR HRE
- Mattei MEH
- Champion XCHP
- Nano Purification D5 EH (US)
Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.
Equivalent equipment at Onyx M3
Purestream (Friulair) refrigerated dryers, distributed by Onyx M3 Inc.
Is your product missing?
Request received. We will proceed within 72 hours.