Comparison · Air dryers

Kaeser air dryers

7 refrigerated, desiccant lines (cycling, heatless, heated purge, blower purge), from the manufacturer’s brochures.

Under construction. This comparison tool is still being built: do not base a purchasing decision on this data. Always confirm with your local distributors.

SECOTEC TA / TB / TC

CYC ISO 5 ≈ North America 60 Hz

Recorded wording: SECOTEC TA-TB-TC (US)

Flow
20 to 138 SCFM (≈ 34 to 234 m³/h)at the manufacturer’s reference conditions
Dew point
3.3 °C (37.9 °F)PDP 38 °F
ISO 8573-1 class
Class 5 (derived)
Frequency
60 Hz
Voltages
115/1/60 · 230/1/60
CSA · CRN
n/a · n/a

Models

All models: Type CyclingDew point 3.3 °C (37.9 °F)ISO class Class 5 (derived)

Model Flow ConditionsVoltage
SECOTEC TA 5SECOTEC TA–TC 20 SCFM≈ 34 m³/h ISO 7183 A2: 0.30 kW ; 100 psig/100 °F115/1/60
SECOTEC TA 8SECOTEC TA–TC 30 SCFM≈ 51 m³/h ISO 7183 A2: 0.37 kW ; 100 psig/100 °F115/1/60
SECOTEC TA 11SECOTEC TA–TC 45 SCFM≈ 76 m³/h ISO 7183 A2: 0.45 kW ; 100 psig/100 °F115/1/60
SECOTEC TB 19SECOTEC TA–TC 74 SCFM≈ 126 m³/h ISO 7183 A2: 0.60 / 0.52 kW ; 100 psig/100 °F115/1/60 or 230/1/60
SECOTEC TB 26SECOTEC TA–TC 90 SCFM≈ 153 m³/h ISO 7183 A2: 0.75 / 0.82 kW ; 100 psig/100 °F115/1/60 or 230/1/60
SECOTEC TC 31SECOTEC TA–TC 113 SCFM≈ 192 m³/h ISO 7183 A2: 0.97 / 1.12 kW ; 100 psig/100 °F115/1/60 or 230/1/60
SECOTEC TC 36SECOTEC TA–TC 138 SCFM≈ 234 m³/h ISO 7183 A2: 1.04 / 1.19 kW ; 100 psig/100 °F115/1/60 or 230/1/60
Comparable lines (6)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

SECOTEC TD / TE / TF / TG

CYC North America 60 Hz

Recorded wording: SECOTEC TD-TE-TF-TG (US)

Flow
162 to 3,070 SCFM (≈ 275 to 5,216 m³/h)at the manufacturer’s reference conditions
Dew point
n/a
ISO 8573-1 class
n/a
Frequency
60 Hz
Voltages
230/1/60 · 208/3/60 · 230/3/60 · 460/3/60 · 575/3/60
CSA · CRN
n/a · n/a

Models

All models: Type Cycling

Model Flow ConditionsVoltage
SECOTEC TD 52SECOTEC TD–TG 162 SCFM≈ 275 m³/h ISO 7183 A2: 0.88 kW ; 100 psig/100 °F230/1/60
SECOTEC TD 67SECOTEC TD–TG 212 SCFM≈ 360 m³/h ISO 7183 A2: 1.11 kW ; 100 psig/100 °F230/1/60
SECOTEC TD 73SECOTEC TD–TG 244 SCFM≈ 415 m³/h ISO 7183 A2: 1.16 kW ; 100 psig/100 °F230/1/60
SECOTEC TD 94SECOTEC TD–TG 279 SCFM≈ 474 m³/h ISO 7183 A2: 1.23 kW ; 100 psig/100 °F230/1/60
SECOTEC TE 120SECOTEC TD–TG 388 SCFM≈ 659 m³/h ISO 7183 A2: 1.6 kW ; 100 psig/100 °F208/230/460/575 V 3/60
SECOTEC TE 143SECOTEC TD–TG 452 SCFM≈ 768 m³/h ISO 7183 A2: 1.7 kW ; 100 psig/100 °F208/230/460/575 V 3/60
SECOTEC TE 155SECOTEC TD–TG 487 SCFM≈ 827 m³/h ISO 7183 A2: 1.9 kW ; 100 psig/100 °F208/230/460/575 V 3/60
SECOTEC TF 174SECOTEC TD–TG 550 SCFM≈ 934 m³/h ISO 7183 A2: 2.5 kW ; 100 psig/100 °F208/230/460/575 V 3/60
SECOTEC TF 230SECOTEC TD–TG 740 SCFM≈ 1,257 m³/h ISO 7183 A2: 3.7 kW ; 100 psig/100 °F208/230/460/575 V 3/60
SECOTEC TF 280SECOTEC TD–TG 900 SCFM≈ 1,529 m³/h ISO 7183 A2: 4.2 kW ; 100 psig/100 °F208/230/460/575 V 3/60
SECOTEC TF 340SECOTEC TD–TG 1,130 SCFM≈ 1,920 m³/h ISO 7183 A2: 4.5 kW ; 100 psig/100 °F208/230/460/575 V 3/60
SECOTEC TG 450SECOTEC TD–TG 1,340 SCFM≈ 2,277 m³/h ISO 7183 A2: 5.1 kW ; 100 psig/100 °F460/3/60
SECOTEC TG 520SECOTEC TD–TG 1,550 SCFM≈ 2,633 m³/h ISO 7183 A2: 6.0 kW ; 100 psig/100 °F460/3/60
SECOTEC TG 650SECOTEC TD–TG 1,910 SCFM≈ 3,245 m³/h ISO 7183 A2: 7.2 kW ; 100 psig/100 °F460/3/60
SECOTEC TG 780SECOTEC TD–TG 2,330 SCFM≈ 3,959 m³/h ISO 7183 A2: 9.0 kW ; 100 psig/100 °F460/3/60
SECOTEC TG 980SECOTEC TD–TG 3,070 SCFM≈ 5,216 m³/h ISO 7183 A2: 14.9 kW ; 100 psig/100 °F460/3/60
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

DC-HF

HL ISO 1–2 ≈ North America 60 Hz 50 Hz
Flow
7 to 40 SCFM (≈ 12 to 68 m³/h)at the manufacturer’s reference conditions
Dew point
-70 to -40 °C (-94 to -40 °F)-40 °F (or -94 °F)
ISO 8573-1 class
Class 1 to 2 (derived)
Frequency
50 Hz · 60 Hz
Voltages
120/1/50-60
CSA · CRN
n/a · n/a

KAD

HL ISO 1–3 North America
Flow
40 to 5,400 SCFM (≈ 68 to 9,175 m³/h)at the manufacturer’s reference conditions
Dew point
-70 to -20 °C (-94 to -4 °F)-40 °F (options -4 °F / -94 °F)
ISO 8573-1 class
Classes 1, 2, 3
Frequency
n/a
Voltages
n/a
CSA · CRN
n/a · n/a

Models

All models: Type HeatlessConditions @100 psigDew point -70 to -20 °C (-94 to -4 °F)ISO class Classes 1, 2, 3

Model Flow
KAD 40 40 SCFM≈ 68 m³/h
KAD 60 60 SCFM≈ 102 m³/h
KAD 90 90 SCFM≈ 153 m³/h
KAD 115 115 SCFM≈ 195 m³/h
KAD 165 165 SCFM≈ 280 m³/h
KAD 260 260 SCFM≈ 442 m³/h
KAD 370 370 SCFM≈ 629 m³/h
KAD 450 450 SCFM≈ 765 m³/h
KAD 590 590 SCFM≈ 1,002 m³/h
KAD 750 750 SCFM≈ 1,274 m³/h
KAD 930 930 SCFM≈ 1,580 m³/h
KAD 1130 1,130 SCFM≈ 1,920 m³/h
KAD 1350 1,350 SCFM≈ 2,294 m³/h
KAD 1550 1,550 SCFM≈ 2,633 m³/h
KAD 2100 2,100 SCFM≈ 3,568 m³/h
KAD 3000 3,000 SCFM≈ 5,097 m³/h
KAD 4100 4,100 SCFM≈ 6,966 m³/h
KAD 5400 5,400 SCFM≈ 9,175 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

i.DC 16-1555

HL ISO 2 Europe / international 60 Hz 50 Hz
Flow
96 to 9,330 m³/h (≈ 57 to 5,491 SCFM)at the manufacturer’s reference conditions
Dew point
-70 to 3 °C (-94 to 37.4 °F)-40 °C (options -70 / -20 / +3 °C)
ISO 8573-1 class
Class 2
Frequency
50 Hz · 60 Hz
Voltages
100-240/1/50-60
CSA · CRN
n/a · n/a

Models

All models: Type HeatlessConditions ISO 7183 optional A1Dew point -70 to 3 °C (-94 to 37.4 °F)ISO class Class 2Voltage 100-240/1/50-60

Model Flow
i.DC 16 ≈ 57 SCFM96 m³/h
i.DC 23 ≈ 81 SCFM138 m³/h
i.DC 34 ≈ 120 SCFM204 m³/h
i.DC 52 ≈ 184 SCFM312 m³/h
i.DC 67 ≈ 237 SCFM402 m³/h
i.DC 84 ≈ 297 SCFM504 m³/h
i.DC 115 ≈ 406 SCFM690 m³/h
i.DC 140 ≈ 494 SCFM840 m³/h
i.DC 225 ≈ 795 SCFM1,350 m³/h
i.DC 275 ≈ 971 SCFM1,650 m³/h
i.DC 330 ≈ 1,165 SCFM1,980 m³/h
i.DC 395 ≈ 1,395 SCFM2,370 m³/h
i.DC 450 ≈ 1,589 SCFM2,700 m³/h
i.DC 610 ≈ 2,154 SCFM3,660 m³/h
i.DC 870 ≈ 3,072 SCFM5,220 m³/h
i.DC 1190 ≈ 4,202 SCFM7,140 m³/h
i.DC 1555 ≈ 5,491 SCFM9,330 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

KBD

BP ISO 2 ≈ North America
Flow
500 to 4,300 SCFM (≈ 850 to 7,306 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °F
ISO 8573-1 class
Class 2 (derived)
Frequency
n/a
Voltages
n/a
CSA · CRN
n/a · n/a

Models

All models: Type Blower purgeConditions @100 psig 100 °FDew point -40 °C (-40 °F)ISO class Class 2 (derived)

Model Flow
KBD 500 500 SCFM≈ 850 m³/h
KBD 600 600 SCFM≈ 1,019 m³/h
KBD 750 750 SCFM≈ 1,274 m³/h
KBD 900 900 SCFM≈ 1,529 m³/h
KBD 1050 1,050 SCFM≈ 1,784 m³/h
KBD 1300 1,300 SCFM≈ 2,209 m³/h
KBD 1500 1,500 SCFM≈ 2,549 m³/h
KBD 1800 1,800 SCFM≈ 3,058 m³/h
KBD 2200 2,200 SCFM≈ 3,738 m³/h
KBD 2600 2,600 SCFM≈ 4,417 m³/h
KBD 3200 3,200 SCFM≈ 5,437 m³/h
KBD 3600 3,600 SCFM≈ 6,116 m³/h
KBD 4300 4,300 SCFM≈ 7,306 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

KED

EH ISO 2–3 ≈ North America
Flow
300 to 3,200 SCFM (≈ 510 to 5,437 m³/h)at the manufacturer’s reference conditions
Dew point
-40 to -20 °C (-40 to -4 °F)-4 °F (-40 °F with optional booster purge)
ISO 8573-1 class
Class 2 to 3 (derived)
Frequency
n/a
Voltages
n/a
CSA · CRN
n/a · n/a

Models

All models: Type Heated purgeConditions @100 psig 100 °FDew point -40 to -20 °C (-40 to -4 °F)ISO class Class 2 to 3 (derived)

Model Flow
KED 300 300 SCFM≈ 510 m³/h
KED 400 400 SCFM≈ 680 m³/h
KED 500 500 SCFM≈ 850 m³/h
KED 600 600 SCFM≈ 1,019 m³/h
KED 750 750 SCFM≈ 1,274 m³/h
KED 900 900 SCFM≈ 1,529 m³/h
KED 1050 1,050 SCFM≈ 1,784 m³/h
KED 1300 1,300 SCFM≈ 2,209 m³/h
KED 1500 1,500 SCFM≈ 2,549 m³/h
KED 1800 1,800 SCFM≈ 3,058 m³/h
KED 2200 2,200 SCFM≈ 3,738 m³/h
KED 2600 2,600 SCFM≈ 4,417 m³/h
KED 3200 3,200 SCFM≈ 5,437 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

Equivalent equipment at Onyx M3

Purestream (Friulair) refrigerated dryers, distributed by Onyx M3 Inc.

Is your product missing?