Comparison · Air dryers

Gardner Denver air dryers

6 refrigerated, desiccant lines (non-cycling, cycling, heatless, blower purge), from the manufacturer’s brochures.

Under construction. This comparison tool is still being built: do not base a purchasing decision on this data. Always confirm with your local distributors.

GDDF-ES

CYC ISO 4 Europe / international 50 Hz
Flow
54 to 5,400 m³/h (≈ 32 to 3,178 SCFM)at the manufacturer’s reference conditions (calc. from 0.9–90 m³/min)
Dew point
3 °C (37.4 °F)ISO class 4 (+3 °C)
ISO 8573-1 class
Class 4
Frequency
50 Hz
Voltages
230/1/50 · 400/3/50
CSA · CRN
n/a · n/a
Features
Energy-saving mode

Models

All models: Type CyclingDew point 3 °C (37.4 °F)ISO class Class 4

Model Flow Voltage
GDD9F-ES ≈ 32 SCFM54 m³/h 230/1/50
GDD12F-ES ≈ 42 SCFM72 m³/h 230/1/50
GDD18F-ES ≈ 64 SCFM108 m³/h 230/1/50
GDD24F-ES ≈ 85 SCFM144 m³/h 230/1/50
GDD30F-ES ≈ 106 SCFM180 m³/h 230/1/50
GDD40F-ES ≈ 141 SCFM240 m³/h 230/1/50
GDD50F-ES ≈ 177 SCFM300 m³/h 230/1/50
GDD60F-ES ≈ 212 SCFM360 m³/h 230/1/50
GDD80F-ES ≈ 283 SCFM480 m³/h 230/1/50
GDD100F-ES ≈ 353 SCFM600 m³/h 230/1/50
GDD130F-ES ≈ 459 SCFM780 m³/h 400/3/50
GDD160F-ES ≈ 559 SCFM949.8 m³/h 400/3/50
GDD216F-ES ≈ 765 SCFM1,300.2 m³/h 400/3/50
GDD250F-ES ≈ 883 SCFM1,500 m³/h 400/3/50
GDD300F-ES ≈ 1,059 SCFM1,800 m³/h 400/3/50
GDD375F-ES ≈ 1,324 SCFM2,250 m³/h 400/3/50
GDD430F-ES ≈ 1,530 SCFM2,599.8 m³/h 400/3/50
GDD533F-ES ≈ 1,883 SCFM3,199.8 m³/h 400/3/50
GDD700F-ES ≈ 2,472 SCFM4,200 m³/h 400/3/50
GDD800F-ES ≈ 2,825 SCFM4,800 m³/h 400/3/50
GDD900F-ES ≈ 3,178 SCFM5,400 m³/h 400/3/50
Comparable lines (6)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

XGNC

NON-CYC ISO 4–5 North America 60 Hz
Flow
75 to 1,600 SCFM (≈ 127 to 2,718 m³/h)at the manufacturer’s reference conditions
Dew point
n/aISO 8573-1 class 4–5
ISO 8573-1 class
Class 4 to 5
Frequency
60 Hz
Voltages
115/1/60 · 460/3/60
CSA · CRN
n/a · n/a

Models

All models: Type Non-cyclingISO class Class 4 to 5

Model Flow Voltage
XGNCA75 75 SCFM120 m³/h 115/1/60
XGNCA100 100 SCFM160 m³/h 115/1/60
XGNCA150 150 SCFM240 m³/h 115/1/60
XGNCA200 200 SCFM321 m³/h 115/1/60
XGNCA250 250 SCFM401 m³/h 115/1/60
XGNC300 300 SCFM510 m³/h 460/3/60
XGNC400 400 SCFM680 m³/h 460/3/60
XGNC500 500 SCFM850 m³/h 460/3/60
XGNC600 600 SCFM1,020 m³/h 460/3/60
XGNC700 700 SCFM1,190 m³/h 460/3/60
XGNC800 800 SCFM1,360 m³/h 460/3/60
XGNC1000 1,000 SCFM1,700 m³/h 460/3/60
XGNC1200 1,200 SCFM2,040 m³/h 460/3/60
XGNC1600 1,600 SCFM2,718 m³/h 460/3/60
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

GDD / GDDF / GDDA

NON-CYC ISO 4–5 ≈ Europe / international 50 Hz

Recorded wording: GDD / GDDF / GDDA (APAC)

Flow
25 to 23,040 m³/h (≈ 15 to 13,561 SCFM)at the manufacturer’s reference conditions (calc. from 0.42–384 m³/min)
Dew point
3 to 7 °C (37.4 to 44.6 °F)PDP +3 °C (tables 3/5/7 °C)
ISO 8573-1 class
Class 4 to 5 (derived)
Frequency
50 Hz
Voltages
230/1/50 · 400/3/50
CSA · CRN
n/a · n/a

Models

All models: Type Non-cyclingISO class Class 4

Model Flow Dew pointVoltage
GDD4FGDD F (APAC) ≈ 15 SCFM25.2 m³/h 3 to 7 °C (37.4 to 44.6 °F)230/1/50
GDD7FGDD F (APAC) ≈ 25 SCFM42 m³/h 3 to 7 °C (37.4 to 44.6 °F)230/1/50
GDD9FGDD F (APAC) ≈ 32 SCFM54 m³/h 3 to 7 °C (37.4 to 44.6 °F)230/1/50
GDD12FGDD F (APAC) ≈ 42 SCFM72 m³/h 3 to 7 °C (37.4 to 44.6 °F)230/1/50
GDD18FGDD F (APAC) ≈ 64 SCFM108 m³/h 3 to 7 °C (37.4 to 44.6 °F)230/1/50
GDD24FGDD F (APAC) ≈ 85 SCFM144 m³/h 3 to 7 °C (37.4 to 44.6 °F)230/1/50
GDD30FGDD F (APAC) ≈ 106 SCFM180 m³/h 3 to 7 °C (37.4 to 44.6 °F)230/1/50
GDD37FGDD F (APAC) ≈ 132 SCFM225 m³/h 3 to 7 °C (37.4 to 44.6 °F)230/1/50
GDD43FGDD F (APAC) ≈ 153 SCFM259.8 m³/h 3 to 7 °C (37.4 to 44.6 °F)230/1/50
GDD50FGDD F (APAC) ≈ 177 SCFM300 m³/h 3 to 7 °C (37.4 to 44.6 °F)230/1/50
GDD60FGDD F (APAC) ≈ 212 SCFM360 m³/h 3 to 7 °C (37.4 to 44.6 °F)230/1/50
GDD80FGDD F (APAC) ≈ 283 SCFM480 m³/h 3 to 7 °C (37.4 to 44.6 °F)230/1/50
GDD100FGDD F (APAC) ≈ 353 SCFM600 m³/h 3 to 7 °C (37.4 to 44.6 °F)230/1/50
GDD130FGDD F (APAC) ≈ 459 SCFM780 m³/h 3 to 7 °C (37.4 to 44.6 °F)400/3/50
GDD160FGDD F (APAC) ≈ 559 SCFM949.8 m³/h 3 to 7 °C (37.4 to 44.6 °F)400/3/50
GDD216FGDD F (APAC) ≈ 765 SCFM1,300.2 m³/h 3 to 7 °C (37.4 to 44.6 °F)400/3/50
GDD250FGDD F (APAC) ≈ 883 SCFM1,500 m³/h 3 to 7 °C (37.4 to 44.6 °F)400/3/50
GDD300FGDD F (APAC) ≈ 1,059 SCFM1,800 m³/h 3 to 7 °C (37.4 to 44.6 °F)400/3/50
GDD375FGDD F (APAC) ≈ 1,324 SCFM2,250 m³/h 3 to 7 °C (37.4 to 44.6 °F)400/3/50
GDD430FGDD F (APAC) ≈ 1,530 SCFM2,599.8 m³/h 3 to 7 °C (37.4 to 44.6 °F)n/a
GDD533FGDD F (APAC) ≈ 1,883 SCFM3,199.8 m³/h 3 to 7 °C (37.4 to 44.6 °F)400/3/50
GDD700FGDD F (APAC) ≈ 2,472 SCFM4,200 m³/h 3 to 7 °C (37.4 to 44.6 °F)400/3/50
GDD800FGDD F (APAC) ≈ 2,825 SCFM4,800 m³/h 3 to 7 °C (37.4 to 44.6 °F)400/3/50
GDD900FGDD F (APAC) ≈ 3,178 SCFM5,400 m³/h 3 to 7 °C (37.4 to 44.6 °F)400/3/50
GDD1460FGDD F (APAC) ≈ 5,180 SCFM8,800.2 m³/h 3 to 7 °C (37.4 to 44.6 °F)400/3/50
GDD1600FGDD F (APAC) ≈ 5,650 SCFM9,600 m³/h 3 to 7 °C (37.4 to 44.6 °F)400/3/50
GDD1920FGDD F (APAC) ≈ 6,769 SCFM11,500.2 m³/h 3 to 7 °C (37.4 to 44.6 °F)400/3/50
GDD2920F–GDD3840F (mentioned)GDD F (APAC) ≈ 13,561 SCFM23,040 m³/h 3 °C (37.4 °F)n/a
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

DGH

HL ISO 1–4 North America CSA
Flow
40 to 5,400 SCFM (≈ 68 to 9,175 m³/h)at the manufacturer’s reference conditions
Dew point
-73 to 3 °C (-99.4 to 37.4 °F)Selectable -100 °F/-73 °C, -40 °F/-40 °C, -4 °F/-20 °C, +38 °F/+3 °C
ISO 8573-1 class
Classes 1, 2, 3, 4
Frequency
n/a
Voltages
n/a
CSA · CRN
yes : « Models are UL and CSA certified » · n/a

Models

All models: Type HeatlessConditions @100 psig (7 bar)Dew point -73 to 3 °C (-99.4 to 37.4 °F)ISO class Classes 1, 2, 3, 4

Model Flow
DGH40 40 SCFM≈ 68 m³/h
DGH60 60 SCFM≈ 102 m³/h
DGH90 90 SCFM≈ 153 m³/h
DGH115 115 SCFM≈ 195 m³/h
DGH165 165 SCFM≈ 280 m³/h
DGH260 260 SCFM≈ 442 m³/h
DGH370 370 SCFM≈ 629 m³/h
DGH450 450 SCFM≈ 765 m³/h
DGH590 590 SCFM≈ 1,002 m³/h
DGH750 750 SCFM≈ 1,274 m³/h
DGH930 930 SCFM≈ 1,580 m³/h
DGH1130 1,130 SCFM≈ 1,920 m³/h
DGH1350 1,350 SCFM≈ 2,294 m³/h
DGH1550 1,550 SCFM≈ 2,633 m³/h
DGH2100 2,100 SCFM≈ 3,568 m³/h
DGH3000 3,000 SCFM≈ 5,097 m³/h
DGH4100 4,100 SCFM≈ 6,966 m³/h
DGH5400 5,400 SCFM≈ 9,175 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

XGHL

HL ISO 1 North America
Flow
90 to 5,000 SCFM (150 to 8,496 m³/h)at the manufacturer’s reference conditions
Dew point
-73 °C (-99.4 °F)n/a standard (optional class 1 -100 °F / -73 °C)
ISO 8573-1 class
Class 1
Frequency
n/a
Voltages
n/a
CSA · CRN
n/a · n/a

Models

All models: Type HeatlessDew point -73 °C (-99.4 °F)ISO class Class 1

Model Flow
XGHL90 90 SCFM150 m³/h
XGHL120 120 SCFM204 m³/h
XGHL160 160 SCFM270 m³/h
XGHL200 200 SCFM342 m³/h
XGHL250 250 SCFM426 m³/h
XGHL300 300 SCFM510 m³/h
XGHL400 400 SCFM678 m³/h
XGHL500 500 SCFM852 m³/h
XGHL600 600 SCFM1,020 m³/h
XGHL800 800 SCFM1,362 m³/h
XGHL1000 1,000 SCFM1,698 m³/h
XGHL1200 1,200 SCFM2,040 m³/h
XGHL1500 1,500 SCFM2,550 m³/h
XGHL1800 1,800 SCFM3,060 m³/h
XGHL2100 2,100 SCFM3,570 m³/h
XGHL2700 2,700 SCFM4,590 m³/h
XGHL3300 3,300 SCFM5,610 m³/h
XGHL4000 4,000 SCFM6,798 m³/h
XGHL5000 5,000 SCFM8,496 m³/h
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

GBPD

BP ISO 2 ≈ North America
Flow
100 to 4,000 SCFM (≈ 170 to 6,796 m³/h)at the manufacturer’s reference conditions
Dew point
-62.2 °C (-80 °F)n/a standard (up to -80 °F optional)
ISO 8573-1 class
Class 2 (derived)
Frequency
n/a
Voltages
n/a
CSA · CRN
n/a · n/a

Models

All models: Type Blower purgeConditions @100 psigDew point -62.2 °C (-80 °F)ISO class Class 2 (derived)

Model Flow
GBPD100 100 SCFM≈ 170 m³/h
GBPD125 125 SCFM≈ 212 m³/h
GBPD175 175 SCFM≈ 297 m³/h
GBPD250 250 SCFM≈ 425 m³/h
GBPD350 350 SCFM≈ 595 m³/h
GBPD500 500 SCFM≈ 850 m³/h
GBPD650 650 SCFM≈ 1,104 m³/h
GBPD800 800 SCFM≈ 1,359 m³/h
GBPD1000 1,000 SCFM≈ 1,699 m³/h
GBPD1250 1,250 SCFM≈ 2,124 m³/h
GBPD1400 1,400 SCFM≈ 2,379 m³/h
GBPD1600 1,600 SCFM≈ 2,718 m³/h
GBPD1800 1,800 SCFM≈ 3,058 m³/h
GBPD2000 2,000 SCFM≈ 3,398 m³/h
GBPD2250 2,250 SCFM≈ 3,823 m³/h
GBPD2500 2,500 SCFM≈ 4,248 m³/h
GBPD2750 2,750 SCFM≈ 4,672 m³/h
GBPD3000 3,000 SCFM≈ 5,097 m³/h
GBPD3500 3,500 SCFM≈ 5,947 m³/h
GBPD4000 4,000 SCFM≈ 6,796 m³/h
Comparable lines (8)