Comparison · Air dryers

Atlas Copco air dryers

17 refrigerated, desiccant lines (non-cycling, variable speed (vsd), blower purge, heatless, heat of compression (hoc), heated purge, rotary drum), from the manufacturer’s brochures.

Under construction. This comparison tool is still being built: do not base a purchasing decision on this data. Always confirm with your local distributors.

FD / FD VSD / FX

NON-CYCVSD ISO 4 ≈ Worldwide 60 Hz 50 Hz

Recorded wording: FD 5-95 / FD VSD 100-300 / FX 5-300

Flow
11 to 636 SCFM (18 to 1,080 m³/h)at the manufacturer’s reference conditions (calc. from 5–300 l/s)
Dew point
3 °C (37.4 °F)PDP +3 °C / 37.4 °F
ISO 8573-1 class
Class 4 (derived)
Frequency
50 Hz · 60 Hz
Voltages
230/1/50 · 115-230/1/60 · 400/3/50 · 460/3/60
CSA · CRN
n/a · n/a

Models

All models: Dew point 3 °C (37.4 °F)

Model Flow TypeISO classVoltage
FX 5FX 5-300 13 SCFM21.6 m³/h Non-cyclingClass 4 (derived)230/1/50; 115-230/1/60
FD 5FD 5-95 13 SCFM21.6 m³/h Non-cyclingClass 4n/a
FX 10FX 5-300 21 SCFM36 m³/h Non-cyclingClass 4 (derived)230/1/50; 115-230/1/60
FD 10FD 5-95 21 SCFM36 m³/h Non-cyclingClass 4n/a
FX 15FX 5-300 30 SCFM50.4 m³/h Non-cyclingClass 4 (derived)230/1/50; 115-230/1/60
FD 15FD 5-95 32 SCFM54 m³/h Non-cyclingClass 4n/a
FX 20FX 5-300 42 SCFM72 m³/h Non-cyclingClass 4 (derived)230/1/50; 115-230/1/60
FD 20FD 5-95 42 SCFM72 m³/h Non-cyclingClass 4n/a
FD 25FD 5-95 53 SCFM90 m³/h Non-cyclingClass 4n/a
FX 30FX 5-300 64 SCFM108 m³/h Non-cyclingClass 4 (derived)230/1/50; 115-230/1/60
FD 30FD 5-95 64 SCFM108 m³/h Non-cyclingClass 4n/a
FX 40FX 5-300 83 SCFM140.4 m³/h Non-cyclingClass 4 (derived)230/1/50; 115-230/1/60
FD 40FD 5-95 85 SCFM144 m³/h Non-cyclingClass 4n/a
FX 50FX 5-300 106 SCFM180 m³/h Non-cyclingClass 4 (derived)230/1/50; 115-230/1/60
FD 50FD 5-95 106 SCFM180 m³/h Non-cyclingClass 4n/a
FX 60FX 5-300 127 SCFM216 m³/h Non-cyclingClass 4 (derived)230/1/50; 115-230/1/60
FD 60FD 5-95 127 SCFM216 m³/h Non-cyclingClass 4n/a
FX 70FX 5-300 144 SCFM244.8 m³/h Non-cyclingClass 4 (derived)230/1/50; 115-230/1/60
FD 70FD 5-95 148 SCFM252 m³/h Non-cyclingClass 4n/a
FX 90FX 5-300 184 SCFM313.2 m³/h Non-cyclingClass 4 (derived)230/1/50; 115-230/1/60
FD 95FD 5-95 201 SCFM342 m³/h Non-cyclingClass 4n/a
FD 100 VSDFD VSD 100-300 212 SCFM360 m³/h Variable speed (VSD)Class 4n/a
FX 110FX 5-300 229 SCFM388.8 m³/h Non-cyclingClass 4 (derived)230/1/50; 230/1/60
FX 130FX 5-300 271 SCFM460.8 m³/h Non-cyclingClass 4 (derived)230/1/50; 230/1/60
FD 140 VSDFD VSD 100-300 297 SCFM504 m³/h Variable speed (VSD)Class 4n/a
FX 170FX 5-300 354 SCFM601.2 m³/h Non-cyclingClass 4 (derived)400/3/50; 460/3/60
FD 180 VSDFD VSD 100-300 381 SCFM648 m³/h Variable speed (VSD)Class 4n/a
FX 200FX 5-300 424 SCFM720 m³/h Non-cyclingClass 4 (derived)400/3/50; 460/3/60
FD 220 VSDFD VSD 100-300 466 SCFM792 m³/h Variable speed (VSD)Class 4n/a
FX 250FX 5-300 530 SCFM900 m³/h Non-cyclingClass 4 (derived)400/3/50; 460/3/60
FD 260 VSDFD VSD 100-300 551 SCFM936 m³/h Variable speed (VSD)Class 4n/a
FX 300FX 5-300 636 SCFM1,080 m³/h Non-cyclingClass 4 (derived)400/3/50; 460/3/60
FD 300 VSDFD VSD 100-300 636 SCFM1,080 m³/h Variable speed (VSD)Class 4n/a
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

FX 1-21

NON-CYC ISO 4–5 ≈ Worldwide 60 Hz 50 Hz
Flow
14 to 2,516 SCFM (25 to 4,450 m³/h)at the manufacturer’s reference conditions (calc. from 7–1236 l/s)
Dew point
3 to 5 °C (37.4 to 41 °F)PDP +3 °C/37 °F (60 Hz), +5 °C/41 °F (50 Hz)
ISO 8573-1 class
Class 4 to 5 (derived)
Frequency
50 Hz · 60 Hz
Voltages
230/1/50 · 400/3/50 · 460/3/60
CSA · CRN
n/a · n/a

Models

All models: Type Non-cyclingDew point 3 to 5 °C (37.4 to 41 °F)ISO class Class 4 to 5 (derived)

Model Flow Voltage
FX 1FX 1-21 (former line) 13 SCFM21.6 m³/h 230/1/50; 115-230/1/60
FX 2FX 1-21 (former line) 21 SCFM36 m³/h 230/1/50; 115-230/1/60
FX 3FX 1-21 (former line) 30 SCFM50.4 m³/h 230/1/50; 115-230/1/60
FX 4FX 1-21 (former line) 42 SCFM72 m³/h 230/1/50; 115-230/1/60
FX 5FX 1-21 (former line) 64 SCFM108 m³/h 230/1/50; 115-230/1/60
FX 6FX 1-21 (former line) 83 SCFM140.4 m³/h 230/1/50; 115-230/1/60
FX 7FX 1-21 (former line) 106 SCFM180 m³/h 230/1/50; 115-230/1/60
FX 8FX 1-21 (former line) 127 SCFM216 m³/h 230/1/50; 115-230/1/60
FX 9FX 1-21 (former line) 144 SCFM244.8 m³/h 230/1/50; 115-230/1/60
FX 10FX 1-21 (former line) 184 SCFM313.2 m³/h 230/1/50; 115-230/1/60
FX 11FX 1-21 (former line) 229 SCFM388.8 m³/h 230/1/50; 230/1/60
FX 12FX 1-21 (former line) 271 SCFM460.8 m³/h 230/1/50; 230/1/60
FX 13FX 1-21 (former line) 354 SCFM601.2 m³/h 400/3/50; 460/3/60
FX 14FX 1-21 (former line) 424 SCFM720 m³/h 400/3/50; 460/3/60
FX 15FX 1-21 (former line) 530 SCFM900 m³/h 400/3/50; 460/3/60
FX 16FX 1-21 (former line) 636 SCFM1,080 m³/h 400/3/50; 460/3/60
FX 17FX 1-21 (former line) 848 SCFM1,440 m³/h 400/3/50; 460/3/60
FX 18FX 1-21 (former line) 1,060 SCFM1,800 m³/h 400/3/50; 460/3/60
FX 19FX 1-21 (former line) 1,236 SCFM2,098.8 m³/h 400/3/50; 460/3/60
FX 19.5FX 1-21 (former line) 1,527 SCFM2,700 m³/h 400/3/50; 460/3/60
FX 20FX 1-21 (former line) 1,766 SCFM2,998.8 m³/h 400/3/50; 460/3/60
FX 21FX 1-21 (former line) 2,374 SCFM4,197.6 m³/h 400/3/50; 460/3/60
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

F 5-130

NON-CYC ISO 5 Worldwide 50 Hz

Recorded wording: F 5-130 (F series)

Flow
n/aat the manufacturer’s reference conditions
Dew point
7 °C (44.6 °F)PDP 7 °C; ISO 8573-1 class 5
ISO 8573-1 class
Class 5
Frequency
50 Hz (60 Hz : yes (mentioned))
Voltages
230/1/50 · 115/1 (UL, F 5-50)
CSA · CRN
n/a · n/a

CD+ 1-1400

HL Worldwide 60 Hz 50 Hz
Flow
2 to 2,968 SCFM (4 to 5,040 m³/h)at the manufacturer’s reference conditions
Dew point
n/a
ISO 8573-1 class
n/a
Frequency
50 Hz · 60 Hz
Voltages
n/a
CSA · CRN
n/a · n/a

CD 1-5

HL ISO 1–2 Worldwide 60 Hz 50 Hz
Flow
2.1 to 9.5 SCFM (3.6 to 16.2 m³/h)at the manufacturer’s reference conditions
Dew point
-70 to -40 °C (-94 to -40 °F)
ISO 8573-1 class
Class 1 to 2
Frequency
50 Hz · 60 Hz
Voltages
n/a
CSA · CRN
n/a · n/a

Models

All models: Type HeatlessConditions FAD 7 bar(e)/100 psig

Model Flow Dew pointISO class
CD 1 2.1 SCFM3.6 m³/h -70 °C (-94 °F)Class 1
CD 1.5 3.2 SCFM5.4 m³/h -40 °C (-40 °F)Class 2
CD 2 4.2 SCFM7.2 m³/h -70 °C (-94 °F)Class 1
CD 3 6.4 SCFM10.8 m³/h -40 °C (-40 °F)Class 2
CD 3.5 7.4 SCFM12.6 m³/h -70 °C (-94 °F)Class 1
CD 5 9.5 SCFM16.2 m³/h -40 °C (-40 °F)Class 2
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

CD+ 5-335

HL ISO 1–3 Worldwide 60 Hz 50 Hz
Flow
11.7 to 699 SCFM (19.8 to 1,188 m³/h)at the manufacturer’s reference conditions
Dew point
-70 to -20 °C (-94 to -4 °F)
ISO 8573-1 class
Classes 1, 2, 3
Frequency
50 Hz · 60 Hz
Voltages
n/a
CSA · CRN
n/a · n/a

Models

All models: Type HeatlessConditions FAD 7 bar(e)/100 psig

Model Flow Dew pointISO class
CD 5+ 11.7 SCFM19.8 m³/h -40 °C (-40 °F)Class 2
CD 8+ 17 SCFM28.8 m³/h -20 °C (-4 °F)Class 3
CD 9+ 19.1 SCFM32.4 m³/h -70 °C (-94 °F)Class 1
CD 10+ 21.2 SCFM36 m³/h -40 °C (-40 °F)Class 2
CD 12+ 25.4 SCFM43.2 m³/h -70 °C (-94 °F)Class 1
CD 15+ 31.8 SCFM54 m³/h -70 to -40 °C (-94 to -40 °F)Class 1 to 2
CD 16+ 33.9 SCFM57.6 m³/h -20 °C (-4 °F)Class 3
CD 18+ 38.1 SCFM64.8 m³/h -70 °C (-94 °F)Class 1
CD 20+ 42.4 SCFM72 m³/h -40 °C (-40 °F)Class 2
CD 23+ 48.7 SCFM82.8 m³/h -20 °C (-4 °F)Class 3
CD 25+ 53 SCFM90 m³/h -70 to -40 °C (-94 to -40 °F)Class 1 to 2
CD 30+ 63.6 SCFM108 m³/h -40 to -20 °C (-40 to -4 °F)Class 2 to 3
CD 35+ 74 SCFM126 m³/h -70 °C (-94 °F)Class 1
CD 37+ 78.4 SCFM133.2 m³/h -20 °C (-4 °F)Class 3
CD 40+ 85 SCFM144 m³/h -40 °C (-40 °F)Class 2
CD 44+ 93.2 SCFM158.4 m³/h -20 °C (-4 °F)Class 3
CD 45+ 95 SCFM162 m³/h -70 °C (-94 °F)Class 1
CD 50+ 106 SCFM180 m³/h -20 °C (-4 °F)Class 3
CD 55+ 117 SCFM198 m³/h -70 to -40 °C (-94 to -40 °F)Class 1 to 2
CD 65+ 138 SCFM234 m³/h -70 to -20 °C (-94 to -4 °F)Classes 1, 2, 3
CD 80+ 170 SCFM288 m³/h -20 °C (-4 °F)Class 3
CD 85+ 180 SCFM306 m³/h -40 °C (-40 °F)Class 2
CD 90+ 191 SCFM324 m³/h -70 °C (-94 °F)Class 1
CD 105+ 222 SCFM378 m³/h -40 to -20 °C (-40 to -4 °F)Class 2 to 3
CD 110+ 233 SCFM396 m³/h -70 °C (-94 °F)Class 1
CD 125+ 265 SCFM450 m³/h -40 to -20 °C (-40 to -4 °F)Class 2 to 3
CD 130+ 275 SCFM468 m³/h -70 °C (-94 °F)Class 1
CD 150+ 318 SCFM540 m³/h -20 °C (-4 °F)Class 3
CD 165+ 350 SCFM594 m³/h -70 °C (-94 °F)Class 1
CD 170+ 360 SCFM612 m³/h -40 °C (-40 °F)Class 2
CD 190+ 403 SCFM684 m³/h -40 °C (-40 °F)Class 2
CD 195+ 413 SCFM702 m³/h -70 to -20 °C (-94 to -4 °F)Classes 1, 3
CD 225+ 477 SCFM810 m³/h -20 °C (-4 °F)Class 3
CD 250+ 530 SCFM900 m³/h -40 °C (-40 °F)Class 2
CD 300+ 636 SCFM1,080 m³/h -20 °C (-4 °F)Class 3
CD 335+ 699 SCFM1,188 m³/h -40 °C (-40 °F)Class 2
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

CD 25-260

HL ISO 2–3 Worldwide 60 Hz 50 Hz
Flow
53 to 551 SCFM (90 to 936 m³/h)at the manufacturer’s reference conditions
Dew point
-40 to -20 °C (-40 to -4 °F)-40 °C / -40 °F ; -20 °C / -5 °F
ISO 8573-1 class
Class 2 to 3
Frequency
50 Hz · 60 Hz
Voltages
n/a
CSA · CRN
n/a · n/a

CD+ 110-300

HL ISO 1–2 Worldwide 60 Hz 50 Hz
Flow
227 to 636 SCFM (385 to 1,080 m³/h)at the manufacturer’s reference conditions
Dew point
-70 to -40 °C (-94 to -40 °F)-70 °C or -40 °C (optional)
ISO 8573-1 class
Class 1 to 2
Frequency
50 Hz · 60 Hz
Voltages
n/a
CSA · CRN
n/a · n/a

CD 360-1600

HL ISO 2 ≈ Worldwide 60 Hz 50 Hz CRN
Flow
763 to 3,392 SCFM (1,296 to 5,760 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °C / -40 °F
ISO 8573-1 class
Class 2 (derived)
Frequency
50 Hz · 60 Hz
Voltages
n/a
CSA · CRN
n/a · yes (stated in brochure)

BD+

BP ISO 1–2 Worldwide 60 Hz 50 Hz
Flow
212 to 6,360 SCFM (360 to 10,800 m³/h)at the manufacturer’s reference conditions
Dew point
-70 to -40 °C (-94 to -40 °F)
ISO 8573-1 class
Class 1 to 2
Frequency
50 Hz · 60 Hz
Voltages
n/a
CSA · CRN
n/a · n/a

Models

All models: Type Blower purgeConditions FAD 7 bar(e)/100 psigDew point -70 to -40 °C (-94 to -40 °F)ISO class Class 1 to 2

Model Flow
BD 100+ 212 SCFM360 m³/h
BD 150+ 318 SCFM540 m³/h
BD 185+ 392 SCFM666 m³/h
BD 250+ 530 SCFM900 m³/h
BD 300+ 636 SCFM1,080 m³/h
BD 330+ 700 SCFM1,188 m³/h
BD 400+ 848 SCFM1,440 m³/h
BD 550+ 1,166 SCFM1,980 m³/h
BD 850+ 1,802 SCFM3,060 m³/h
BD 1100+ 2,332 SCFM3,960 m³/h
BD 1400+ 2,968 SCFM5,040 m³/h
BD 1800+ 3,816 SCFM6,480 m³/h
BD 2200+ 4,664 SCFM7,920 m³/h
BD 3000+ 6,360 SCFM10,800 m³/h
Comparable lines (3)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

BD+ ZP

BP ISO 1–2 Worldwide 60 Hz 50 Hz
Flow
212 to 6,360 SCFM (360 to 10,800 m³/h)at the manufacturer’s reference conditions
Dew point
-70 to -40 °C (-94 to -40 °F)
ISO 8573-1 class
Class 1 to 2
Frequency
50 Hz · 60 Hz
Voltages
n/a
CSA · CRN
n/a · n/a

Models

All models: Type Blower purgeConditions FAD 7 bar(e)/100 psigDew point -70 to -40 °C (-94 to -40 °F)ISO class Class 1 to 2

Model Flow
BD 100+ ZP 212 SCFM360 m³/h
BD 150+ ZP 318 SCFM540 m³/h
BD 185+ ZP 392 SCFM666 m³/h
BD 250+ ZP 530 SCFM900 m³/h
BD 300+ ZP 636 SCFM1,080 m³/h
BD 330+ ZP 700 SCFM1,188 m³/h
BD 400+ ZP 848 SCFM1,440 m³/h
BD 550+ ZP 1,166 SCFM1,980 m³/h
BD 850+ ZP 1,802 SCFM3,060 m³/h
BD 1100+ ZP 2,332 SCFM3,960 m³/h
BD 1400+ ZP 2,968 SCFM5,040 m³/h
BD 1800+ ZP 3,816 SCFM6,480 m³/h
BD 2200+ ZP 4,664 SCFM7,920 m³/h
BD 3000+ ZP 6,360 SCFM10,800 m³/h
Comparable lines (3)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

BD 360-1600

BP ISO 2 ≈ Worldwide 60 Hz 50 Hz CRN
Flow
763 to 3,392 SCFM (1,296 to 5,760 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °C / -40 °F
ISO 8573-1 class
Class 2 (derived)
Frequency
50 Hz · 60 Hz
Voltages
n/a
CSA · CRN
n/a · yes (stated in brochure)

AD 360-1600

EH ISO 2 ≈ Worldwide 60 Hz 50 Hz CRN
Flow
763 to 3,392 SCFM (1,296 to 5,760 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °C / -40 °F
ISO 8573-1 class
Class 2 (derived)
Frequency
50 Hz · 60 Hz
Voltages
n/a
CSA · CRN
n/a · yes (stated in brochure)

XD+

HOC Worldwide 60 Hz 50 Hz
Flow
1,166 to 7,632 SCFM (1,980 to 12,960 m³/h)at the manufacturer’s reference conditions
Dew point
n/a
ISO 8573-1 class
n/a
Frequency
50 Hz · 60 Hz
Voltages
n/a
CSA · CRN
n/a · n/a

Models

All models: Type Heat of compression (HOC)Conditions FAD 7 bar(e)/100 psig

Model Flow
XD 550+ 1,166 SCFM1,980 m³/h
XD 850+ 1,802 SCFM3,060 m³/h
XD 1100+ 2,332 SCFM3,960 m³/h
XD 1400+ 2,968 SCFM5,040 m³/h
XD 1800+ 3,816 SCFM6,480 m³/h
XD 2200+ 4,664 SCFM7,920 m³/h
XD 3000+ 6,360 SCFM10,800 m³/h
XD 3600+ 7,632 SCFM12,960 m³/h
Comparable lines (5)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

MD (rotary drum)

DRUM ISO 3–4 ≈ Worldwide CRN
Flow
424 to 7,628 SCFM (720 to 12,960 m³/h)at the manufacturer’s reference conditions
Dew point
-30 to 0 °C (-22 to 32 °F)0 to -30 °C (32 to -22 °F)
ISO 8573-1 class
Class 3 to 4 (derived)
Frequency
n/a
Voltages
n/a
CSA · CRN
n/a · yes (stated in brochure)

Models

All models: Type Rotary drumConditions FAD 7 bar(e)/100 psigDew point -30 to 0 °C (-22 to 32 °F)ISO class Class 3 to 4 (derived)

Model Flow
MD 200 A 424 SCFM720 m³/h
MD 200 W 424 SCFM720 m³/h
MD 300 A 636 SCFM1,080 m³/h
MD 300 W 636 SCFM1,080 m³/h
MD 400 A 848 SCFM1,440 m³/h
MD 400 W 848 SCFM1,440 m³/h
MD 400 VSD A 848 SCFM1,440 m³/h
MD 400 VSD W 848 SCFM1,440 m³/h
MD 600 A 1,271 SCFM2,160 m³/h
MD 600 W 1,271 SCFM2,160 m³/h
MD 800 VSD A 1,271 SCFM2,160 m³/h
MD 800 VSD W 1,271 SCFM2,160 m³/h
MD 1000 W 1,695 SCFM2,880 m³/h
MD 1100 VSD W 2,119 SCFM3,600 m³/h
MD 1300 VSD W 2,119 SCFM3,600 m³/h
MD 1800 W 3,814 SCFM6,480 m³/h
MD 2000 W 3,814 SCFM6,480 m³/h
MD 2100 VSD W 3,814 SCFM6,480 m³/h
MD 2500 VSD W 3,814 SCFM6,480 m³/h
MD 4000 W 7,628 SCFM12,960 m³/h
Comparable lines (0)

No comparable line in the current data.

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

ND (rotary drum)

DRUM ISO 2–4 ≈ Worldwide CRN
Flow
636 to 7,628 SCFM (1,080 to 12,960 m³/h)at the manufacturer’s reference conditions
Dew point
-45 to 0 °C (-49 to 32 °F)0 to -45 °C (32 to -49 °F)
ISO 8573-1 class
Classes 2, 4 (derived)
Frequency
n/a
Voltages
n/a
CSA · CRN
n/a · yes (stated in brochure)

Models

All models: Type Rotary drumConditions FAD 7 bar(e)/100 psigDew point -45 to 0 °C (-49 to 32 °F)ISO class Classes 2, 4 (derived)

Model Flow
ND 300 A 636 SCFM1,080 m³/h
ND 300 W 636 SCFM1,080 m³/h
ND 400 A 848 SCFM1,440 m³/h
ND 400 W 848 SCFM1,440 m³/h
ND 400 VSD A 848 SCFM1,440 m³/h
ND 400 VSD W 848 SCFM1,440 m³/h
ND 600 A 1,271 SCFM2,160 m³/h
ND 600 W 1,271 SCFM2,160 m³/h
ND 800 VSD A 1,271 SCFM2,160 m³/h
ND 800 VSD W 1,271 SCFM2,160 m³/h
ND 1000 W 1,695 SCFM2,880 m³/h
ND 1100 VSD W 2,119 SCFM3,600 m³/h
ND 1300 VSD W 2,119 SCFM3,600 m³/h
ND 1800 W 3,814 SCFM6,480 m³/h
ND 2000 W 3,814 SCFM6,480 m³/h
ND 2100 VSD W 3,814 SCFM6,480 m³/h
ND 2500 VSD W 3,814 SCFM6,480 m³/h
ND 4000 W 7,628 SCFM12,960 m³/h
Comparable lines (0)

No comparable line in the current data.

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

MDG (rotary drum)

DRUM ISO 2 ≈ Worldwide CRN
Flow
847 SCFM (1,440 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °C/°F and below
ISO 8573-1 class
Class 2 (derived)
Frequency
n/a
Voltages
n/a
CSA · CRN
n/a · yes (stated in brochure)

Models

Model Flow TypeConditionsDew pointISO class
MDG 450 W 847 SCFM1,440 m³/h Rotary drumFAD 7 bar(e)/100 psig-40 °C (-40 °F)Class 2 (derived)