Comparison · Air dryers

Worthington Creyssensac air dryers

4 refrigerated, desiccant lines (non-cycling, heatless), from the manufacturer’s brochures.

Under construction. This comparison tool is still being built: do not base a purchasing decision on this data. Always confirm with your local distributors.

DW 2-720

NON-CYC ISO 5 ≈ Worldwide 60 Hz 50 Hz
Flow
12.4 to 4,238 SCFM (21 to 7,200 m³/h)at the manufacturer’s reference conditions
Dew point
4 °C (39.2 °F)PDP +4 °C ±1
ISO 8573-1 class
Class 5 (derived)
Frequency
50 Hz · 60 Hz
Voltages
230/1/50 · 230/1/60 · 400/3/50 · 460/3/60
CSA · CRN
n/a · n/a

Models

All models: Type Non-cyclingDew point 4 °C (39.2 °F)ISO class Class 4

Model Flow Voltage
DW 2DW 12.4 SCFM21 m³/h 230/1/50 ; 230/1/60
DW 3DW 21.2 SCFM36 m³/h 230/1/50 ; 230/1/60
DW 5DW 30 SCFM51 m³/h 230/1/50 ; 230/1/60
DW 7DW 42.4 SCFM72 m³/h 230/1/50 ; 230/1/60
DW 10DW 63.6 SCFM108 m³/h 230/1/50 ; 230/1/60
DW 13DW 83 SCFM141 m³/h 230/1/50 ; 230/1/60
DW 17DW 106 SCFM180 m³/h 230/1/50 ; 230/1/60
DW 21DW 127 SCFM216 m³/h 230/1/50 ; 230/1/60
DW 25DW 145 SCFM246 m³/h 230/1/50 ; 230/1/60
DW 31DW 184 SCFM312 m³/h 230/1/50 ; 230/1/60
DW 39DW 230 SCFM390 m³/h 230/1/50 ; 230/1/60
DW 46DW 272 SCFM462 m³/h 230/1/50 ; 230/1/60
DW 60DW 353 SCFM600 m³/h 400/3/50 ; 460/3/60
DW 72DW 424 SCFM720 m³/h 400/3/50 ; 460/3/60
DW 90DW 530 SCFM900 m³/h 400/3/50 ; 460/3/60
DW 108DW 636 SCFM1,080 m³/h 400/3/50 ; 460/3/60
DW 144DW 848 SCFM1,440 m³/h 400/3/50 ; 460/3/60
DW 180DW 1,059 SCFM1,800 m³/h 400/3/50 ; 460/3/60
DW 210DW 1,236 SCFM2,100 m³/h 400/3/50 ; 460/3/60
DW 270DW 1,589 SCFM2,700 m³/h 400/3/50 ; 460/3/60
DW 300DW 1,766 SCFM3,000 m³/h 400/3/50 ; 460/3/60
DW 374DW 2,204 SCFM3,744 m³/h 400/3/50 ; 460/3/60
DW 420DW 2,472 SCFM4,200 m³/h 400/3/50 ; 460/3/60
DW 504DW 2,966 SCFM5,040 m³/h 400/3/50 ; 460/3/60
DW 594DW 3,496 SCFM5,940 m³/h 400/3/50 ; 460/3/60
DW 720DW 4,238 SCFM7,200 m³/h 400/3/50 ; 460/3/60
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

DB 05-6

HL ISO 1–2 ≈ Europe / international 60 Hz 50 Hz
Flow
7 to 59 m³/h (≈ 4 to 35 SCFM)at the manufacturer’s reference conditions
Dew point
-70 to -40 °C (-94 to -40 °F)-40 °C (-70 °C with derating, factor 0.7)
ISO 8573-1 class
Class 1 to 2 (derived)
Frequency
50 Hz · 60 Hz
Voltages
100-115-230 VAC 50/60 Hz or 12-24 VDC
CSA · CRN
n/a · n/a

DB 65-130

HL ISO 1–2 ≈ Europe / international 60 Hz 50 Hz
Flow
648 to 1,548 m³/h (≈ 381 to 911 SCFM)at the manufacturer’s reference conditions
Dew point
-70 to -40 °C (-94 to -40 °F)-40 °C (-70 °C optional with derating)
ISO 8573-1 class
Class 1 to 2 (derived)
Frequency
50 Hz · 60 Hz
Voltages
230 VAC 50/60 Hz
CSA · CRN
n/a · n/a

DB 90-940

HL ISO 1–3 ≈ Europe / international 60 Hz 50 Hz
Flow
90 to 936 m³/h (≈ 53 to 551 SCFM)at the manufacturer’s reference conditions
Dew point
-70 to -20 °C (-94 to -4 °F)-40 °C std (-20 °C version; -70 °C with derating from DB 125)
ISO 8573-1 class
Classes 1, 2, 3 (derived)
Frequency
50 Hz · 60 Hz
Voltages
115-230 VAC 50/60 Hz
CSA · CRN
n/a · n/a

Equivalent equipment at Onyx M3

Purestream (Friulair) refrigerated dryers, distributed by Onyx M3 Inc.

Is your product missing?