Comparison · Air dryers

ALUP air dryers

4 refrigerated, desiccant lines (non-cycling, heatless), from the manufacturer’s brochures.

Under construction. This comparison tool is still being built: do not base a purchasing decision on this data. Always confirm with your local distributors.

ADQ 21-7200

NON-CYC ISO 5 ≈ Europe / international 50 Hz
Flow
12.4 to 4,238 SCFM (21 to 7,200 m³/h)at the manufacturer’s reference conditions
Dew point
4 °C (39.2 °F)PDP +4 °C ±1
ISO 8573-1 class
Class 5 (derived)
Frequency
50 Hz
Voltages
230/50/1 · 400/50/3
CSA · CRN
n/a · n/a

Models

All models: Type Non-cyclingDew point 4 °C (39.2 °F)ISO class Class 4

Model Flow Voltage
ADQ 21 12.4 SCFM21 m³/h 230/50/1
ADQ 36 21.2 SCFM36 m³/h 230/50/1
ADQ 51 30 SCFM51 m³/h 230/50/1
ADQ 72 42.4 SCFM72 m³/h 230/50/1
ADQ 110 64.4 SCFM110 m³/h 230/50/1
ADQ 141 83 SCFM141 m³/h 230/50/1
ADQ 180 106 SCFM180 m³/h 230/50/1
ADQ 216 127 SCFM216 m³/h 230/50/1
ADQ 246 145 SCFM246 m³/h 230/50/1
ADQ 312 184 SCFM312 m³/h 230/50/1
ADQ 312 G 184 SCFM312 m³/h 230/50/1
ADQ 390 230 SCFM390 m³/h 230/50/1
ADQ 462 272 SCFM462 m³/h 230/50/1
ADQ 462 G 272 SCFM462 m³/h 230/50/1
ADQ 600 353 SCFM600 m³/h 400/50/3
ADQ 720 424 SCFM720 m³/h 400/50/3
ADQ 900 530 SCFM900 m³/h 400/50/3
ADQ 1080 636 SCFM1,080 m³/h 400/50/3
ADQ 1080 G 636 SCFM1,080 m³/h 400/50/3
ADQ 1440 848 SCFM1,440 m³/h 400/50/3
ADQ 1800 1,059 SCFM1,800 m³/h 400/50/3
ADQ 2100 1,236 SCFM2,100 m³/h 400/50/3
ADQ 2700 1,589 SCFM2,700 m³/h 400/50/3
ADQ 3000 1,766 SCFM3,000 m³/h 400/50/3
ADQ 3740 2,204 SCFM3,744 m³/h 400/50/3
ADQ 4200 2,472 SCFM4,200 m³/h 400/50/3
ADQ 5040 2,966 SCFM5,040 m³/h 400/50/3
ADQ 5940 3,496 SCFM5,940 m³/h 400/50/3
ADQ 7200 4,238 SCFM7,200 m³/h 400/50/3
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

AD 7-60

HL ISO 1–2 ≈ Europe / international 60 Hz 50 Hz
Flow
7 to 59 m³/h (≈ 4 to 35 SCFM)at the manufacturer’s reference conditions
Dew point
-70 to -40 °C (-94 to -40 °F)-40 °C std (-70 °C with derating)
ISO 8573-1 class
Class 1 to 2 (derived)
Frequency
50 Hz · 60 Hz
Voltages
12-24 VDC / 100-115-230 VAC
CSA · CRN
n/a · n/a

AD 650-1300 (sensor)

HL ISO 1–2 ≈ Europe / international 60 Hz 50 Hz
Flow
648 to 1,548 m³/h (≈ 381 to 911 SCFM)at the manufacturer’s reference conditions
Dew point
-70 to -40 °C (-94 to -40 °F)-40 °C std (-70 °C optional)
ISO 8573-1 class
Class 1 to 2 (derived)
Frequency
50 Hz · 60 Hz
Voltages
230 VAC
CSA · CRN
n/a · n/a

AD 90-940

HL ISO 1–3 ≈ Europe / international 60 Hz 50 Hz
Flow
90 to 936 m³/h (≈ 53 to 551 SCFM)at the manufacturer’s reference conditions
Dew point
-70 to -20 °C (-94 to -4 °F)-20 / -40 °C std (-70 °C optional AD125+)
ISO 8573-1 class
Classes 1, 2, 3 (derived)
Frequency
50 Hz · 60 Hz
Voltages
115-230 VAC
CSA · CRN
n/a · n/a

Equivalent equipment at Onyx M3

Purestream (Friulair) refrigerated dryers, distributed by Onyx M3 Inc.