Comparison · Air dryers

Deltech air dryers

4 refrigerated, desiccant lines (non-cycling, cycling, heatless, heated purge), from the manufacturer’s brochures.

Under construction. This comparison tool is still being built: do not base a purchasing decision on this data. Always confirm with your local distributors.

FLEX

CYC North America 60 Hz
Flow
75 to 2,000 SCFM (127 to 3,400 m³/h)at the manufacturer’s reference conditions
Dew point
n/a
ISO 8573-1 class
n/a
Frequency
60 Hz
Voltages
115/1/60 · 460/3/60
CSA · CRN
n/a · n/a
Features
Energy-saving mode

DPRB

NON-CYC North America 60 Hz CSA
Flow
7 to 1,200 SCFM (12 to 2,040 m³/h)at the manufacturer’s reference conditions
Dew point
n/a
ISO 8573-1 class
n/a
Frequency
60 Hz
Voltages
115/1/60 · 460/3/60
CSA · CRN
yes (CSA 22.2 #60335-1/-2-40) · n/a

Models

All models: Type Non-cyclingConditions ISO 7183 optional A2 (100 psig/100 °F

Model Flow Voltage
DPRB7A 7 SCFM≈ 12 m³/h 115/1/60
DPRB11A 11 SCFM≈ 19 m³/h 115/1/60
DPRB15A 15 SCFM≈ 25 m³/h 115/1/60
DPRB25A 25 SCFM≈ 42 m³/h 115/1/60
DPRB32A 32 SCFM≈ 54 m³/h 115/1/60
DPRB42A 42 SCFM≈ 71 m³/h 115/1/60
DPRB50A 50 SCFM≈ 85 m³/h 115/1/60
DPRB75A 75 SCFM≈ 127 m³/h 115/1/60
DPRB100A 100 SCFM≈ 170 m³/h 115/1/60
DPRB125A 125 SCFM≈ 212 m³/h 115/1/60
DPRB150A 150 SCFM≈ 255 m³/h 115/1/60
DPRB200A 200 SCFM≈ 340 m³/h 460/3/60
DPRB250A 250 SCFM≈ 425 m³/h 460/3/60
DPRB300A 300 SCFM≈ 510 m³/h 460/3/60
DPRB400A 400 SCFM≈ 680 m³/h 460/3/60
DPRB500A 500 SCFM≈ 850 m³/h 460/3/60
DPRB600A 600 SCFM≈ 1,019 m³/h 460/3/60
DPRB800A 800 SCFM≈ 1,359 m³/h 460/3/60
DPRB1000A 1,000 SCFM≈ 1,699 m³/h 460/3/60
DPRB1200A 1,200 SCFM≈ 2,039 m³/h 460/3/60
Comparable lines (8)

Same type, overlapping flows, equal or better ISO class. Published facts, no ranking.

DHDM (modular)

HL ISO 1–2 North America CSA
Flow
3 to 177 SCFM (≈ 5 to 301 m³/h)at the manufacturer’s reference conditions
Dew point
-70 to -40 °C (-94 to -40 °F)-40 °F/-40 °C (class 2) or -94 °F/-70 °C (class 1), selectable
ISO 8573-1 class
Class 1 to 2
Frequency
n/a
Voltages
n/a
CSA · CRN
yes : CSA C22.2 No.0-10 / No.14-18 & UL 508 · n/a

RP

EH ISO 2 North America
Flow
250 to 3,200 SCFM (≈ 425 to 5,437 m³/h)at the manufacturer’s reference conditions
Dew point
-40 °C (-40 °F)-40 °F/-40 °C (class 2)
ISO 8573-1 class
Class 2
Frequency
n/a
Voltages
n/a
CSA · CRN
n/a · n/a

Models

All models: Type Heated purgeConditions CAGI ADF 200 @100 psig/100 °FDew point -40 °C (-40 °F)ISO class Class 2

Model Flow
RP-250 250 SCFM≈ 425 m³/h
RP-300 300 SCFM≈ 510 m³/h
RP-400 400 SCFM≈ 680 m³/h
RP-500 500 SCFM≈ 850 m³/h
RP-600 600 SCFM≈ 1,019 m³/h
RP-750 750 SCFM≈ 1,274 m³/h
RP-900 900 SCFM≈ 1,529 m³/h
RP-1050 1,050 SCFM≈ 1,784 m³/h
RP-1300 1,300 SCFM≈ 2,209 m³/h
RP-1500 1,500 SCFM≈ 2,549 m³/h
RP-1800 1,800 SCFM≈ 3,058 m³/h
RP-2200 2,200 SCFM≈ 3,738 m³/h
RP-2600 2,600 SCFM≈ 4,417 m³/h
RP-3200 3,200 SCFM≈ 5,437 m³/h