Measurement tools

Choosing a compressed air flow meter

Flow is the data point most often missing in a compressed air room. You know the compressors’ power and the network pressure, but rarely how much air the plant actually uses, when, and where it goes. Without that measurement, you cannot track a compressor’s efficiency, put a number on leaks or allocate consumption between departments.

The right flow meter comes down to four questions: where to measure (and therefore air quality), pipe diameter, operating pressure, and how long you measure. This article follows them in the order of the selection tool from VPInstruments, maker of the VPFlowScope flow meters distributed by Onyx M3.

Only need a one-off reading? A compressor’s real capacity can also be checked without a flow meter, with the pump-up test.

Two measuring technologies

Industrial compressed air flow meters mostly rely on two principles:

  • Thermal mass: a heated sensor measures the cooling caused by the flow. It gives mass flow directly (expressed as normalized flow, SCFM), with no pressure or temperature correction. Its measuring range is wide and reaches very low flows, which makes it the tool for leaks and consumption. It requires dry air: water droplets distort the reading.
  • Differential pressure: the probe measures the pressure difference created by the flow. It tolerates hot, saturated air and suits high velocities, typically at the compressor outlet, before the dryer. Its range starts higher: it is not made to track small flows.

As an example, on a 4 in pipe, the range published by the manufacturer runs from 8.7 to 2610 SCFM for a thermal probe (VPFlowScope Probe or M), versus 348 to 3483 SCFM for the differential pressure probe (VPFlowScope DP).

Question 1: where to measure, and what air quality?

The measuring point sets the technology.

  • Supply side, before the dryer (compressor outlet): the air is hot, saturated and moving fast. This is where differential pressure belongs (VPFlowScope DP). You measure the flow actually produced, to compare it with the power drawn and track compressor efficiency.
  • After the dryer (room outlet, main header, branches, machines): the air is dry, velocity low to medium. This is where thermal mass belongs (VPFlowScope Probe, M or In-line). You measure what the plant uses, by department or by machine, and you track leaks.

VPInstruments reserves differential pressure for wet or high-velocity points, and recommends thermal mass everywhere else, leak monitoring included.

Question 2: what pipe diameter?

  • Under 2 in: in-line flow meter. The VPFlowScope In-line mounts directly in the piping of a workstation or machine. Three sizes cover 0.13 to 600 SCFM: 0.5 in (0.13 to 50 SCFM), 1 in (0.54 to 150 SCFM) and 2 in (2.15 to 600 SCFM). Pick the size from the actual flow of the workstation, not from the diameter of the existing pipe. The inlet and outlet tubing (NPT or BSP) provides the required straight runs.
  • Over 2 in: insertion probe. The VPFlowScope Probe and VPFlowScope M install under pressure on an insertion valve, without shutting the network down. Probe length follows the diameter: 400 or 600 mm for the Probe, 220 mm cartridge (1 to 3 in pipes) or 350 mm cartridge (2.5 in and up) for the M.

For an insertion probe, the inside diameter programmed into the device is used to convert the measured velocity into flow: a wrong value throws off the whole measurement. The ID/OD pipe diameter chart gives the inside diameter of steel, stainless and aluminium pipe.

Question 3: what operating pressure?

ModelPublished maximum pressure
VPFlowScope M, 350 mm cartridge10 bar (145 psi)
VPFlowScope M, 220 mm cartridge16 bar (250 psi)
VPFlowScope Probe16 bar (250 psi); 35 bar (500 psi) option
VPFlowScope In-line16 bar (250 psi); 35 bar (500 psi) option
VPFlowScope DP16 bar (250 psi)

On a large dry-air pipe, the VPInstruments tool points to the VPFlowScope M below 10 bar (145 psi) and to the VPFlowScope Probe between 10 and 16 bar (145 to 250 psi). Above that, the 35 bar option is required.

Question 4: permanent or temporary measurement?

  • Temporary measurement (audit, machine test): a probe with a display and built-in data logger records on site, with no computer. It is the reference setup for compressed air audits. It runs from a mains power adapter.
  • Permanent measurement (energy monitoring): the device transmits continuously to a PLC or monitoring system over 4-20 mA, pulse or Modbus RTU (RS485). The VPFlowScope M adds Ethernet (Modbus TCP). Plan for the 24 VDC supply and the M12 cable.

The VPFlowScope M has one more advantage for permanent use: its measuring cartridge (VPSensorCartridge) is swapped on site, which replaces the yearly shipment for recalibration.

Summary: the four models

ModelTechnologyPipeAirTypical use
VPFlowScope In-lineThermal mass, in-line0.5 to 2 inDryConsumption per machine or workstation, local leaks
VPFlowScope ProbeThermal mass, insertionOver 2 inDryAudits, main headers, up to 16 bar
VPFlowScope MThermal mass, cartridge insertion1 in and upDry, technical gasesPermanent monitoring, room outlet, ring networks
VPFlowScope DPDifferential pressure, insertion2 in and upWet or dryCompressor outlet, compressor efficiency

The flow meter selector walks through these four questions and proposes the model, its configuration and its accessories (cables, power supply, tubing), with part numbers and list prices.

Good measurement starts with the installation

The best flow meter reads poorly if it is poorly installed:

  • Straight runs: for the In-line, roughly 10 pipe diameters of straight pipe upstream and 5 downstream. Insertion probes also need a straight section away from elbows, valves and reducers.
  • Dry air for any thermal probe: never before the dryer.
  • Probe position and depth, flow direction, programmed inside diameter: see the guide Installing the VPFlowScope M insertion flow meter.

Where Onyx M3 comes in

Onyx M3 validates the measuring point, the model and the configuration with you before ordering, and can then handle the installation and the integration of the data into energy monitoring. The VPFlowScope flow meters are presented in the Compressed air flow meters section.

References

Frequently asked questions

Which flow meter technology should I use for compressed air?

For dry air, after the dryer, a thermal mass flow meter: it covers a wide range, down to the very low flows that matter for leak tracking. For hot, saturated air at the compressor outlet, before the dryer, a differential pressure flow meter, because thermal mass assumes dry air and becomes inaccurate in wet air.

In-line flow meter or insertion probe?

Below 2 in, an in-line flow meter mounts directly in the piping of a machine or workstation. Above 2 in, an insertion probe installs under pressure on an insertion valve, without shutting the network down. An in-line meter is sized from the actual flow of the workstation, not from the diameter of the existing pipe.

Up to what pressure do VPFlowScope flow meters work?

The VPFlowScope M is rated up to 10 bar (145 psi) with the 350 mm cartridge and up to 16 bar (250 psi) with the 220 mm one. The VPFlowScope Probe, In-line and DP go up to 16 bar (250 psi). A 35 bar (500 psi) version is available as an option for the In-line and the Probe.

Do I need a permanent flow meter for an audit?

No. An audit is often done with a temporary probe fitted with a display and a built-in data logger, which records on site with no computer. Permanent measurement is for continuous monitoring: 4-20 mA, pulse or Modbus outputs to a PLC or an energy monitoring system.

Can I measure a compressor's flow without a flow meter?

Yes, as a one-off, with the pump-up test: you time the pressure rise of a known volume. It is a good check of a compressor's real capacity, but it does not replace continuous measurement of consumption.

Let’s talk about your compressed air system