Desiccant dryer
MTA NA107
Under construction. This comparison tool is still being built: do not base a purchasing decision on this data. Always confirm with your local distributors.
- Flow
- ≈ 35 SCFM59 m³/h
- Dew point
- -70 to -40 °C (-94 to -40 °F)As published: -40 °C (up to -70 °C)
- ISO 8573-1 class
- Class 1 to 2 (derived)
- Type
- Heatless
- Manufacturer
- MTA
- Line
- DryXtreme NA
- Conditions
- Reference 20 °C/1 bar a, 7 bar(ü), inlet 35 °C, PDP -40 °C
- Voltage
- n/a
- Frequency
- n/a
- Brochure market
- Europe / international
- CSA
- n/a
- CRN
- n/a
- Source
- Manufacturer’s page
Comparable models
Compare side by side| Model | Flow | Dew point | ISO class | Market |
|---|---|---|---|---|
| ALUP AD 60 | ≈ 35 SCFM59 m³/h | -70 to -40 °C (-94 to -40 °F) | Class 1 to 2 (derived) | Europe / international |
| Worthington Creyssensac DB 6 C | ≈ 35 SCFM59 m³/h | -70 to -40 °C (-94 to -40 °F) | Class 1 to 2 (derived) | Europe / international |
| MARK ADS 10 | 34.7 SCFM59 m³/h | -70 to -20 °C (-94 to -4 °F) | Classes 1, 2, 3 (derived) | Europe / international |
| Mattei DD 60 | 34 SCFM60 m³/h | -70 to -20 °C (-94 to -4 °F) | Classes 1, 2, 3 (derived) | Europe / international |
| Donaldson Ultrapac 2000 0065 | ≈ 38 SCFM65 m³/h | -70 to -40 °C (-94 to -40 °F) | Class 1 to 2 (derived) | Europe / international |
| Ultrafilter HL 50 | ≈ 29 SCFM50 m³/h | -70 to -20 °C (-94 to -4 °F) | Classes 1, 3 (derived) | Europe / international |
| FINI HDT 12 | 42 SCFM72 m³/h | -70 to -20 °C (-94 to -4 °F) | Classes 1, 2, 3 (derived) | Europe / international |
| BEKO Technologies ACC 35 | 35 SCFM≈ 59 m³/h | -73.3 to -40 °C (-99.9 to -40 °F) | Class 1 to 2 (derived) | North America |
Same type, flow within ±25%, equal or better ISO class. The closest model from each manufacturer. Flows at each manufacturer’s conditions, no ranking.
Other DryXtreme NA models
Is your product missing?
Request received. We will proceed within 72 hours.