Compressed-air calculator

Metered recovery — receiver and demand cycles

After a demand event, the system must recover its pressure before the next one — otherwise it falls behind cycle after cycle.

This calculator validates a receiver volume against your measured demand cycles: event duration, drawn flow, time available for recovery.

Metered recovery

Receiver sizing and recovery validation across demand cycles.

How to use it

  1. Enter the supply flow (what the compressor delivers continuously) and the event flow (the short demand spike).
  2. Give the start and minimum allowable pressures and the event duration: the tool returns the required receiver and the recovery time.
  3. Fill in “Time between events” to validate recovery — if it is shorter than the recovery time, the receiver cannot recharge in time (shown in red).
  4. Scenario 2 lets you adjust receiver, supply and pressures with sliders to test variations.

Scenario 1 — required

Result

Net demand
SCFM
Required receivergal
ft³ · L
ft³ · L
Recovery time
s · min

Pressure cycle

Tip: enter “Time between events” to see whether recovery fits within the available time.

Volume = (Q_net · t · P_atm) / (60 · ΔP). Scenario 2 validates both volume AND recovery time.

Indicative estimates — validate all results before any technical decision.