Refrigerated dryer · Purestream ACT VS

Purestream ACT VS variable-speed refrigerated air dryer

Variable-speed refrigerated dryer: the refrigerant compressor modulates to the real load → large part-load energy savings. ALU-DRY exchanger, Bekomat zero-loss drain, DMC 50 controller. 800 to 6000 SCFM, 150# flange. UR = 460 V, UQ = 575 V; /A = air-cooled, /W = water-cooled (P.O.A.).

From $31,345 CAD, before taxes. Installation and shipping extra. Price subject to change without notice.

Flow
800–6000 SCFM
Dew point
3 °C (37 °F)
Models
48
Purestream ACT VS variable-speed refrigerated air dryerImage may differ from the actual product.
STEP1
Size it
Enter your actual conditions (pressure, temperatures, flow). We point you to the model to aim for.
STEP2
Choose the model
The recommended model is highlighted in the table. Adjust for voltage and connection.
STEP3
Complete & request
Add the recommended filters, then send your quote request all at once.
1 Sizing for your conditions

Which model for your installation?

Rated flow is given at reference conditions (100 psig · 38 °C). Enter your actual conditions: the calculator applies the correction factors and shows the rated flow to aim for.

Capacity calculator

psig
°C
°C
SCFM
Combined correction factor× 1.00
Minimum rated flow required

Reference charts

Operating pressure
psig6080100120140160180203
barg4.15.56.98.39.71112.414
Factor × 0.79 × 0.91 × 1.00nominal × 1.07 × 1.13 × 1.18 × 1.23 × 1.27

Outside the 60–203 psig range: contact us.

Ambient temperature
°C2732353840434550
°F80.689.695100.4104109.4113122
Factor × 1.11 × 1.09 × 1.06 × 1.00nominal × 0.94 × 0.87 × 0.78 × 0.69

Outside the 27–50 °C range: contact us.

Inlet temperature
°C3238435055606570
°F89.6100.4109.4122131140149158
Factor × 1.16 × 1.00nominal × 0.82 × 0.68 × 0.61 × 0.52 × 0.45 × 0.40

Outside the 32–70 °C range: contact us.

Corrected capacity = rated flow × F(pressure) × F(ambient temperature) × F(inlet temperature). Aim for the model whose corrected rated flow ≥ your need. Source: manufacturer datasheets (Friulair / CAG).

2 Choose a model

48 models · 800–6000 SCFM

CAD list prices, before taxes. The model from the calculator is highlighted. Above 1500 SCFM, 150# flange connection.

48 models shown

Model Flow Voltage Refrig. Conn. Weight Price
ACT800VS-UR/A 800 SCFM 460/3/60 R407C 3" 150# FL. 534 lb242 kg $31,345
ACT1000VS-UR/A 1000 SCFM 460/3/60 R407C 3" 150# FL. 606 lb275 kg $33,322
ACT1250VS-UR/A 1250 SCFM 460/3/60 R407C 3" 150# FL. 686 lb311 kg $37,802
ACT1500VS-UR/A 1500 SCFM 460/3/60 R407C 4" 150# FL. 1168 lb530 kg $50,327
ACT1750VS-UR/A 1750 SCFM 460/3/60 R407C 4" 150# FL. 1283 lb582 kg $53,912
ACT2000VS-UR/A 2000 SCFM 460/3/60 R407C 4" 150# FL. 1312 lb595 kg $55,927
ACT2500VS-UR/A 2500 SCFM 460/3/60 R407C 4" 150# FL. 1567 lb711 kg $61,001
ACT3000VS-UR/A 3000 SCFM 460/3/60 R407C 6" 150# FL. 1855 lb841 kg $82,952
ACT3750VS-UR/A 3750 SCFM 460/3/60 R407C 6" 150# FL. 2100 lb953 kg $95,287
ACT4000VS-UR/A 4000 SCFM 460/3/60 R407C 8" 150# FL. 2356 lb1069 kg $107,595
ACT5000VS-UR/A 5000 SCFM 460/3/60 R407C 8" 150# FL. 2680 lb1216 kg $124,397
ACT6000VS-UR/A 6000 SCFM 460/3/60 R407C 8" 150# FL. 3212 lb1457 kg $151,862
ACT800VS-UR/W 800 SCFM 460/3/60 R407C 3" 150# FL. 534 lb242 kg on request
ACT1000VS-UR/W 1000 SCFM 460/3/60 R407C 3" 150# FL. 606 lb275 kg on request
ACT1250VS-UR/W 1250 SCFM 460/3/60 R407C 3" 150# FL. 686 lb311 kg on request
ACT1500VS-UR/W 1500 SCFM 460/3/60 R407C 4" 150# FL. 1168 lb530 kg on request
ACT1750VS-UR/W 1750 SCFM 460/3/60 R407C 4" 150# FL. 1283 lb582 kg on request
ACT2000VS-UR/W 2000 SCFM 460/3/60 R407C 4" 150# FL. 1312 lb595 kg on request
ACT2500VS-UR/W 2500 SCFM 460/3/60 R407C 4" 150# FL. 1567 lb711 kg on request
ACT3000VS-UR/W 3000 SCFM 460/3/60 R407C 6" 150# FL. 1855 lb841 kg on request
ACT3750VS-UR/W 3750 SCFM 460/3/60 R407C 6" 150# FL. 2100 lb953 kg on request
ACT4000VS-UR/W 4000 SCFM 460/3/60 R407C 8" 150# FL. 2356 lb1069 kg on request
ACT5000VS-UR/W 5000 SCFM 460/3/60 R407C 8" 150# FL. 2680 lb1216 kg on request
ACT6000VS-UR/W 6000 SCFM 460/3/60 R407C 8" 150# FL. 3212 lb1457 kg on request
ACT800VS-UQ/A 800 SCFM 575/3/60 R407C 3" 150# FL. 534 lb242 kg $31,345
ACT1000VS-UQ/A 1000 SCFM 575/3/60 R407C 3" 150# FL. 606 lb275 kg $33,322
ACT1250VS-UQ/A 1250 SCFM 575/3/60 R407C 3" 150# FL. 686 lb311 kg $37,802
ACT1500VS-UQ/A 1500 SCFM 575/3/60 R407C 4" 150# FL. 1168 lb530 kg $50,327
ACT1750VS-UQ/A 1750 SCFM 575/3/60 R407C 4" 150# FL. 1283 lb582 kg $53,912
ACT2000VS-UQ/A 2000 SCFM 575/3/60 R407C 4" 150# FL. 1312 lb595 kg $55,927
ACT2500VS-UQ/A 2500 SCFM 575/3/60 R407C 4" 150# FL. 1567 lb711 kg $61,001
ACT3000VS-UQ/A 3000 SCFM 575/3/60 R407C 6" 150# FL. 1855 lb841 kg $82,952
ACT3750VS-UQ/A 3750 SCFM 575/3/60 R407C 6" 150# FL. 2100 lb953 kg $95,287
ACT4000VS-UQ/A 4000 SCFM 575/3/60 R407C 8" 150# FL. 2356 lb1069 kg $107,595
ACT5000VS-UQ/A 5000 SCFM 575/3/60 R407C 8" 150# FL. 2680 lb1216 kg $124,397
ACT6000VS-UQ/A 6000 SCFM 575/3/60 R407C 8" 150# FL. 3212 lb1457 kg $151,862
ACT800VS-UQ/W 800 SCFM 575/3/60 R407C 3" 150# FL. 534 lb242 kg on request
ACT1000VS-UQ/W 1000 SCFM 575/3/60 R407C 3" 150# FL. 606 lb275 kg on request
ACT1250VS-UQ/W 1250 SCFM 575/3/60 R407C 3" 150# FL. 686 lb311 kg on request
ACT1500VS-UQ/W 1500 SCFM 575/3/60 R407C 4" 150# FL. 1168 lb530 kg on request
ACT1750VS-UQ/W 1750 SCFM 575/3/60 R407C 4" 150# FL. 1283 lb582 kg on request
ACT2000VS-UQ/W 2000 SCFM 575/3/60 R407C 4" 150# FL. 1312 lb595 kg on request
ACT2500VS-UQ/W 2500 SCFM 575/3/60 R407C 4" 150# FL. 1567 lb711 kg on request
ACT3000VS-UQ/W 3000 SCFM 575/3/60 R407C 6" 150# FL. 1855 lb841 kg on request
ACT3750VS-UQ/W 3750 SCFM 575/3/60 R407C 6" 150# FL. 2100 lb953 kg on request
ACT4000VS-UQ/W 4000 SCFM 575/3/60 R407C 8" 150# FL. 2356 lb1069 kg on request
ACT5000VS-UQ/W 5000 SCFM 575/3/60 R407C 8" 150# FL. 2680 lb1216 kg on request
ACT6000VS-UQ/W 6000 SCFM 575/3/60 R407C 8" 150# FL. 3212 lb1457 kg on request
3 Complete the dryer

Recommended in-line filters

When checked, they are added to the quote with each dryer at the right size (sized per model). Adjust or remove on the quote page. Above 1500 SCFM: on request.

* “Oil-free” air: residual oil ≤ 0.003 mg/m³ (oil vapour) (ISO 8573-1 oil class 1), per the AC carbon filter specification.

Where the filters sit around the dryer
  1. Water separatorat compressor
  2. X1Pre-filter
  3. Dryer
  4. XAAfter-filter
  5. ACCarbon
  6. Dry, clean air
  • Water separator: at the compressor : removes bulk liquid water right at the compressor outlet. A separate component from the dryer, required upstream (often already in place). View water separators →
  • X1 pre-filter: before the dryer : stops liquid water, dust and oil aerosols. Protects the dryer’s heat exchanger.
  • XA after-filter: after the dryer : captures fine oil droplets (0.01 µm) for very clean outlet air.
  • AC carbon filter: after (optional) : removes oil vapours and odours: “oil-free” air. Add when needed, rarely required.

Range specifications

Dew point
3 °C (37 °F)
Heat exchanger
ALU-DRY (aluminium)
Drain
Bekomat (purgeur électronique sans perte d'air)
Controller
DMC 50 (sectionneur principal)
Refrigerant(s)
R407C
Nominal conditions
ambient 37.8 °C (100 °F) · inlet 37.8 °C (100 °F) · 7 barg (100 psig) · PDP 3 °C (37 °F)
Max. conditions
ambient 50 °C (122 °F) · inlet 70 °C (158 °F) · 14 barg
Certification (CRN)
to be confirmed

The CRN (pressure vessel) is a legal mention: confirmed before publication.

Videos

Manufacturer demos and guides (CAG Technologies YouTube channel). Videos play right here, without leaving the site: the player only loads on click.

Ready to request a quote?

View my quote request

Add the models you need to your request, then send it all at once from the quote page. Fast response, billing by transfer or purchase order, no online payment.

View my quote request