Refrigerated dryer · Purestream ACT VS

Purestream ACT VS variable-speed refrigerated air dryer

Variable-speed refrigerated dryer: the refrigerant compressor modulates to the real load → large part-load energy savings. ALU-DRY exchanger, Bekomat zero-loss drain, DMC 50 controller. 800 to 6000 SCFM, 150# flange. UR = 460 V, UQ = 575 V; /A = air-cooled, /W = water-cooled (P.O.A.).

From $31,345 CAD, before taxes. Installation and shipping extra. The quote prevails.

Flow
800–6000 SCFM
Dew point
3 °C (37 °F)
Models
48
Purestream ACT VS variable-speed refrigerated air dryerImage may differ from the actual product.
STEP1
Size it
Enter your actual conditions — pressure, temperatures, flow. We point you to the model to aim for.
STEP2
Choose the model
The recommended model is highlighted in the table. Adjust for voltage and connection.
STEP3
Complete & request
Add the recommended filters, then send your quote request all at once.
1 Sizing for your conditions

Which model for your installation?

Rated flow is given at reference conditions (100 psig · 38 °C). Enter your actual conditions: the calculator applies the correction factors and shows the rated flow to aim for.

Capacity calculator

psig
°C
°C
SCFM
Combined correction factor× 1.00
Minimum rated flow required

Reference charts

Operating pressure
psig6080100120140160180203
barg4.15.56.98.39.71112.414
Factor × 0.79 × 0.91 × 1.00nominal × 1.07 × 1.13 × 1.18 × 1.23 × 1.27

Outside the 60–203 psig range: contact us.

Ambient temperature
°C2732353840434550
°F80.689.695100.4104109.4113122
Factor × 1.11 × 1.09 × 1.06 × 1.00nominal × 0.94 × 0.87 × 0.78 × 0.69

Outside the 27–50 °C range: contact us.

Inlet temperature
°C3238435055606570
°F89.6100.4109.4122131140149158
Factor × 1.16 × 1.00nominal × 0.82 × 0.68 × 0.61 × 0.52 × 0.45 × 0.40

Outside the 32–70 °C range: contact us.

Corrected capacity = rated flow × F(pressure) × F(ambient temperature) × F(inlet temperature). Aim for the model whose corrected rated flow ≥ your need. Source: manufacturer datasheets (Friulair / CAG).

2 Choose a model

48 models · 800–6000 SCFM

CAD list prices, before taxes. The model from the calculator is highlighted. Above 1500 SCFM, 150# flange connection.

48 models shown

Model Flow Voltage Refrig. Conn. Weight Price
ACT800VS-UR/A 800 SCFM 460/3/60 R407C 3" 150# FL. 534 lb242 kg $31,345
ACT1000VS-UR/A 1000 SCFM 460/3/60 R407C 3" 150# FL. 606 lb275 kg $33,322
ACT1250VS-UR/A 1250 SCFM 460/3/60 R407C 3" 150# FL. 686 lb311 kg $37,802
ACT1500VS-UR/A 1500 SCFM 460/3/60 R407C 4" 150# FL. 1168 lb530 kg $50,327
ACT1750VS-UR/A 1750 SCFM 460/3/60 R407C 4" 150# FL. 1283 lb582 kg $53,912
ACT2000VS-UR/A 2000 SCFM 460/3/60 R407C 4" 150# FL. 1312 lb595 kg $55,927
ACT2500VS-UR/A 2500 SCFM 460/3/60 R407C 4" 150# FL. 1567 lb711 kg $61,001
ACT3000VS-UR/A 3000 SCFM 460/3/60 R407C 6" 150# FL. 1855 lb841 kg $82,952
ACT3750VS-UR/A 3750 SCFM 460/3/60 R407C 6" 150# FL. 2100 lb953 kg $95,287
ACT4000VS-UR/A 4000 SCFM 460/3/60 R407C 8" 150# FL. 2356 lb1069 kg $107,595
ACT5000VS-UR/A 5000 SCFM 460/3/60 R407C 8" 150# FL. 2680 lb1216 kg $124,397
ACT6000VS-UR/A 6000 SCFM 460/3/60 R407C 8" 150# FL. 3212 lb1457 kg $151,862
ACT800VS-UR/W 800 SCFM 460/3/60 R407C 3" 150# FL. 534 lb242 kg on request
ACT1000VS-UR/W 1000 SCFM 460/3/60 R407C 3" 150# FL. 606 lb275 kg on request
ACT1250VS-UR/W 1250 SCFM 460/3/60 R407C 3" 150# FL. 686 lb311 kg on request
ACT1500VS-UR/W 1500 SCFM 460/3/60 R407C 4" 150# FL. 1168 lb530 kg on request
ACT1750VS-UR/W 1750 SCFM 460/3/60 R407C 4" 150# FL. 1283 lb582 kg on request
ACT2000VS-UR/W 2000 SCFM 460/3/60 R407C 4" 150# FL. 1312 lb595 kg on request
ACT2500VS-UR/W 2500 SCFM 460/3/60 R407C 4" 150# FL. 1567 lb711 kg on request
ACT3000VS-UR/W 3000 SCFM 460/3/60 R407C 6" 150# FL. 1855 lb841 kg on request
ACT3750VS-UR/W 3750 SCFM 460/3/60 R407C 6" 150# FL. 2100 lb953 kg on request
ACT4000VS-UR/W 4000 SCFM 460/3/60 R407C 8" 150# FL. 2356 lb1069 kg on request
ACT5000VS-UR/W 5000 SCFM 460/3/60 R407C 8" 150# FL. 2680 lb1216 kg on request
ACT6000VS-UR/W 6000 SCFM 460/3/60 R407C 8" 150# FL. 3212 lb1457 kg on request
ACT800VS-UQ/A 800 SCFM 575/3/60 R407C 3" 150# FL. 534 lb242 kg $31,345
ACT1000VS-UQ/A 1000 SCFM 575/3/60 R407C 3" 150# FL. 606 lb275 kg $33,322
ACT1250VS-UQ/A 1250 SCFM 575/3/60 R407C 3" 150# FL. 686 lb311 kg $37,802
ACT1500VS-UQ/A 1500 SCFM 575/3/60 R407C 4" 150# FL. 1168 lb530 kg $50,327
ACT1750VS-UQ/A 1750 SCFM 575/3/60 R407C 4" 150# FL. 1283 lb582 kg $53,912
ACT2000VS-UQ/A 2000 SCFM 575/3/60 R407C 4" 150# FL. 1312 lb595 kg $55,927
ACT2500VS-UQ/A 2500 SCFM 575/3/60 R407C 4" 150# FL. 1567 lb711 kg $61,001
ACT3000VS-UQ/A 3000 SCFM 575/3/60 R407C 6" 150# FL. 1855 lb841 kg $82,952
ACT3750VS-UQ/A 3750 SCFM 575/3/60 R407C 6" 150# FL. 2100 lb953 kg $95,287
ACT4000VS-UQ/A 4000 SCFM 575/3/60 R407C 8" 150# FL. 2356 lb1069 kg $107,595
ACT5000VS-UQ/A 5000 SCFM 575/3/60 R407C 8" 150# FL. 2680 lb1216 kg $124,397
ACT6000VS-UQ/A 6000 SCFM 575/3/60 R407C 8" 150# FL. 3212 lb1457 kg $151,862
ACT800VS-UQ/W 800 SCFM 575/3/60 R407C 3" 150# FL. 534 lb242 kg on request
ACT1000VS-UQ/W 1000 SCFM 575/3/60 R407C 3" 150# FL. 606 lb275 kg on request
ACT1250VS-UQ/W 1250 SCFM 575/3/60 R407C 3" 150# FL. 686 lb311 kg on request
ACT1500VS-UQ/W 1500 SCFM 575/3/60 R407C 4" 150# FL. 1168 lb530 kg on request
ACT1750VS-UQ/W 1750 SCFM 575/3/60 R407C 4" 150# FL. 1283 lb582 kg on request
ACT2000VS-UQ/W 2000 SCFM 575/3/60 R407C 4" 150# FL. 1312 lb595 kg on request
ACT2500VS-UQ/W 2500 SCFM 575/3/60 R407C 4" 150# FL. 1567 lb711 kg on request
ACT3000VS-UQ/W 3000 SCFM 575/3/60 R407C 6" 150# FL. 1855 lb841 kg on request
ACT3750VS-UQ/W 3750 SCFM 575/3/60 R407C 6" 150# FL. 2100 lb953 kg on request
ACT4000VS-UQ/W 4000 SCFM 575/3/60 R407C 8" 150# FL. 2356 lb1069 kg on request
ACT5000VS-UQ/W 5000 SCFM 575/3/60 R407C 8" 150# FL. 2680 lb1216 kg on request
ACT6000VS-UQ/W 6000 SCFM 575/3/60 R407C 8" 150# FL. 3212 lb1457 kg on request
3 Complete the dryer

Recommended in-line filters

When checked, they are added to the quote with each dryer at the right size (sized per model). Adjust or remove on the quote page. Above 1500 SCFM: on request.

* “Oil-free” air: residual oil ≤ 0.003 mg/m³ (oil vapour) — ISO 8573-1 oil class 1, per the AC carbon filter specification.

Where the filters sit around the dryer
  1. Water separatorat compressor
  2. X1Pre-filter
  3. Dryer
  4. XAAfter-filter
  5. ACCarbon
  6. Dry, clean air
  • Water separator — at the compressor — removes bulk liquid water right at the compressor outlet. A separate component from the dryer, required upstream (often already in place). View water separators →
  • X1 pre-filter — before the dryer — stops liquid water, dust and oil aerosols. Protects the dryer’s heat exchanger.
  • XA after-filter — after the dryer — captures fine oil droplets (0.01 µm) for very clean outlet air.
  • AC carbon filter — after (optional) — removes oil vapours and odours: “oil-free” air. Add when needed — rarely required.

Range specifications

Dew point
3 °C (37 °F)
Heat exchanger
ALU-DRY (aluminium)
Drain
Bekomat — purgeur électronique sans perte d'air
Controller
DMC 50 (sectionneur principal)
Refrigerant(s)
R407C
Nominal conditions
ambient 37.8 °C (100 °F) · inlet 37.8 °C (100 °F) · 7 barg (100 psig) · PDP 3 °C (37 °F)
Max. conditions
ambient 50 °C (122 °F) · inlet 70 °C (158 °F) · 14 barg
Certification (CRN)
to be confirmed

The CRN (pressure vessel) is a legal mention — confirmed before publication.

Videos

Manufacturer demos and guides (CAG Technologies YouTube channel). Videos play right here, without leaving the site — the player only loads on click.

Ready to request a quote?

View my quote request

Add the models you need to your request, then send it all at once from the quote page. Fast response, billing by transfer or purchase order — no online payment.

View my quote request