X1 coalescing filter — 1 micronImage may differ from the actual product.

Walker Filtration Alpha 2 · Grade X1

X1 coalescing filter — 1 micron

General 1-micron coalescing filter, red end cap. Residual oil carryover ≤ 0.1 mg/m³. The most common grade, upstream and downstream of a dryer.

From $232 CAD, before taxes. Installation and shipping extra. The quote prevails.

Retention
1 µm
Flow
6–1500 SCFM
Sizes
18
Model Flow Conn. Weight Element Price
A3011 6 SCFM 1/8" NPT 0.55 lb0.25 kg E30306X1 $77 $232
A3021 15 SCFM 1/4" NPT 0.55 lb0.25 kg E30306X1 $77 $243
A3022 25 SCFM 1/4" NPT 1.32 lb0.6 kg E30408X1 $96 $260
A3031 32 SCFM 3/8" NPT 1.32 lb0.6 kg E30408X1 $96 $299
A3051 50 SCFM 1/2" NPT 1.54 lb0.6 kg E30412X1 $160 $386
A3052 70 SCFM 1/2" NPT 3.75 lb1.7 kg E30612X1 $181 $451
A3071 85 SCFM 3/4" NPT 3.75 lb1.7 kg E30612X1 $181 $495
A3101 105 SCFM 1" NPT 3.75 lb1.7 kg E30612X1 $181 $544
A3072 125 SCFM 3/4" NPT 4.4 lb2 kg E30621X1 $205 $646
A3102 175 SCFM 1" NPT 4.4 lb2 kg E30621X1 $205 $721
A3122 280 SCFM 1 1/4" NPT 10.8 lb4.9 kg E30831X1 $288 $844
A3151 400 SCFM 1 1/2" NPT 10.8 lb4.9 kg E30831X1 $288 $1,063
A3201 450 SCFM 2" NPT 10.8 lb4.9 kg E30831X1 $288 $1,429
A3202 700 SCFM 2" NPT 12.12 lb5.5 kg E30850X1 $465 $1,759
A3251 850 SCFM 2 1/2" NPT 23.15 lb10.5 kg E31140X1 $627 $2,038
A3301 900 SCFM 3" NPT 23.15 lb10.5 kg E31140X1 $627 $2,175
A3302 1250 SCFM 3" NPT 25.35 lb11.5 kg E31160X1 $844 $2,441
A3303 1500 SCFM 3" NPT 27.56 lb12.5 kg E31175X1 $998 $3,321

Replacement element = Element. CAD, before taxes. Installation and shipping extra. The quote prevails.

Grade specifications

Retention
1 µm
Max. oil carryover
0.1 mg/m³
Air quality (ISO 8573-1)
ISO 8573-1 — particle cl. 2 · oil 2
Pressure loss — clean & dry
0.8 psi (55 mbar)
Pressure loss — saturated
1.8 psi (125 mbar)
Element end cap
red
Max. pressure
232 psig (16 barg)
Max. temperature
120 °C (248 °F)
Certification (CRN)
CRN registered in all Canadian provinces (Walker threaded filters, cast-aluminium, PED 2014/68/EU group-2 compliant).

Sizing for your conditions

Rated flow is given at reference conditions. Enter your actual conditions: the calculator applies the correction factors and shows the rated flow to aim for.

Capacity calculator

psig
SCFM
Combined correction factor× 1.00
Minimum rated flow required
Recommended model

Reference charts

Operating pressure
psig587287100115145174203232300
barg456781012141620.7
Factor × 0.76 × 0.84 × 0.92 × 1.00nominal × 1.07 × 1.19 × 1.31 × 1.41 × 1.51 × 1.73

Outside the 58–300 psig range: contact us.

Rated flow given at 7 barg (100 psig), reference conditions 1 bar(a) 20 °C. For maximum flow, multiply the model flow by the factor for your minimum operating pressure.